ICMSR '18Pub Date : 2018-05-25DOI: 10.1145/3230876.3230900
M. Melichar, D. Kubátová, Jan Kutlwašer
{"title":"Influence of Temperature Compensation for Evaluation by Continuous Scanning","authors":"M. Melichar, D. Kubátová, Jan Kutlwašer","doi":"10.1145/3230876.3230900","DOIUrl":"https://doi.org/10.1145/3230876.3230900","url":null,"abstract":"The paper describes the experimental verification of the influence of temperature compensation for the CMM machines. To confirm the initial theoretical consideration an experiment was carried out - repeated evaluation of a reference component. The obtained values were then used as an input for evaluating the conformity of gauges / machines. Due to the repeated measurements, and a sufficient number of values it is possible to describe the characteristics by the Gaussian normal distribution. Conclusion The article sets a limit on the accuracy of practical applications for contact CMM scanning.","PeriodicalId":424063,"journal":{"name":"ICMSR '18","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132465511","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}