SP-251: Design & Applications of Textile-Reinforced Concrete最新文献

筛选
英文 中文
Strength Degradation of AR-Glass Filaments Due to Cyclic Tensile Loading 循环拉伸载荷对ar玻璃细丝强度的影响
SP-251: Design & Applications of Textile-Reinforced Concrete Pub Date : 2008-03-01 DOI: 10.14359/20151
Bong-Gu Kang, J. Hannawald, W. Brameshuber
{"title":"Strength Degradation of AR-Glass Filaments Due to Cyclic Tensile Loading","authors":"Bong-Gu Kang, J. Hannawald, W. Brameshuber","doi":"10.14359/20151","DOIUrl":"https://doi.org/10.14359/20151","url":null,"abstract":"The tensile load carrying behavior under cyclic loading of filaments made of alkali-resistant glass, which is the basic component of the textile reinforcement used for textile reinforced concrete, has been analyzed. Therefore, tensile tests under cyclic loading at four different stress levels were carried out. A damage accumulation, which led in some cases to a failure of the specimens during the cyclic loading, could be observed. This motivated to introduce a strength degradation model. A calibration of the model parameters on the experimental data was performed using an optimization method. A statistical analysis was carried out beforehand, to estimate the initial tensile strengths of the specimens, which were needed for the calibration.","PeriodicalId":404712,"journal":{"name":"SP-251: Design & Applications of Textile-Reinforced Concrete","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123502066","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Sandwich Panels with Thin-Walled Textile-Reinforced Concrete Facings 薄壁纺织钢筋混凝土面板夹芯板
SP-251: Design & Applications of Textile-Reinforced Concrete Pub Date : 2008-03-01 DOI: 10.14359/20153
J. Hegger, M. Horstmann, A. Scholzen
{"title":"Sandwich Panels with Thin-Walled Textile-Reinforced Concrete Facings","authors":"J. Hegger, M. Horstmann, A. Scholzen","doi":"10.14359/20153","DOIUrl":"https://doi.org/10.14359/20153","url":null,"abstract":"Textile-reinforced concrete (TRC) is a composite material made of open-meshed textile structures and a fine-grained concrete. The application of TRC leads to the design of filigree and lightweight concrete structures with high durability and high quality surfaces. In recent years, TRC has become an attractive choice for the production of ventilated facade systems. To attain the goal of a lightweight facade with large spans and without bracing stud-frame-systems, sandwich panels with two thin TRC-facings and a core of rigid polyurethane foam have been developed at RWTH Aachen University. Within a compact section, this slender building envelope provides a capable load-bearing behavior, superior heat insulation and fire resistance as well as a sufficient sound insulation. In the paper, the investigated production methods, the test results of sandwich members loaded by bending and shear forces, tests on sound insulation and fire resistance, as well as the deduced calculation models are presented.","PeriodicalId":404712,"journal":{"name":"SP-251: Design & Applications of Textile-Reinforced Concrete","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115585845","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Improvement of Serviceability and Strength of Textile-Reinforced Concrete Elements with Short Fiber Mixes 短纤维掺合料提高纺织钢筋混凝土构件的使用性能和强度
SP-251: Design & Applications of Textile-Reinforced Concrete Pub Date : 2008-03-01 DOI: 10.14359/20147
M. Hinzen, W. Brameshuber
{"title":"Improvement of Serviceability and Strength of Textile-Reinforced Concrete Elements with Short Fiber Mixes","authors":"M. Hinzen, W. Brameshuber","doi":"10.14359/20147","DOIUrl":"https://doi.org/10.14359/20147","url":null,"abstract":"Nowadays, thin-walled load bearing structures can be realized using textile-reinforced concrete (Brameshuber and RILEM TC 201-TRC, 2006). The required tensile strength is achieved by embedding several layers of textile. By means of the laminating technique the number of textile layers that can be included into the concrete could be increased. To further increase the first crack strength and the ductility and to optimize the crack development, fine-grained concrete mixtures with short fibers can be used. By simultaneously using different types of short fibers, the positive properties of each fiber may be combined. By a schematic stress-strain curve, the demands on short-fiber mixtures are defined. Within the scope of this study, short fibers made of glass, carbon, aramid, and polyvinyl alcohol are investigated in terms of their ability to fit these requirements. Furthermore, examinations to determine the fiber types and fiber volumes are presented. Finally, two hybrid fiber-reinforced concretes are introduced. On the basis of stress-strain curves of textile-reinforced concrete, the advantages of these fiber mixtures are discussed.","PeriodicalId":404712,"journal":{"name":"SP-251: Design & Applications of Textile-Reinforced Concrete","volume":"16 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114089326","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Textile-Reinforced Concrete for Flexural Strengthening of RC-Structures-Part 1: Structural Behavior and Design Model 混凝土结构抗弯加固用纺织钢筋混凝土-第1部分:结构性能和设计模型
SP-251: Design & Applications of Textile-Reinforced Concrete Pub Date : 2008-03-01 DOI: 10.14359/20148
A. Bösche, F. Jesse, R. Ortlepp, S. Weiland, M. Curbach
{"title":"Textile-Reinforced Concrete for Flexural Strengthening of RC-Structures-Part 1: Structural Behavior and Design Model","authors":"A. Bösche, F. Jesse, R. Ortlepp, S. Weiland, M. Curbach","doi":"10.14359/20148","DOIUrl":"https://doi.org/10.14359/20148","url":null,"abstract":"The use of technical textiles to reinforce concrete (i.e., textile reinforced concrete [TRC]) extends into entirely new areas of application. The thick concrete covers, as required for steel reinforced concrete, are no longer needed due to the corrosion resistance of textile materials. Slender structural members with thicknesses as small as 10 mm (appr. 4 in.) are possible. Additional characteristic features of textile reinforcement include two-dimensional planar characteristics, as well as ease of deformability and adaptability to complex and curved geometries. This can be exemplified by a pedestrian bridge built of TRC. Various geometric forms, such as slabs, beams, T-beams, shells, and columns can easily be strengthened using TRC. Dimensioning of elements and structures using TRC requires detailed knowledge of the load-bearing behavior of this composite material. Indeed, such behavior resembles that of steel reinforced concrete; however, this behavior is more heavily influenced by the bond between the textile reinforcement and the fine concrete, as well as the bond between filaments within the textile reinforcement. Minimal thicknesses also make it possible to strengthen existing concrete structures using TRC. Such strengthening increases both the ultimate load bearing capacity, as well as the serviceability, of the structure. Experimental results of strengthened slabs and beams, as well as a design model for flexural strengthening, is presented in this paper.","PeriodicalId":404712,"journal":{"name":"SP-251: Design & Applications of Textile-Reinforced Concrete","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129319172","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
Textile-Reinforced Concrete for Light Structures 轻型结构用纺织钢筋混凝土
SP-251: Design & Applications of Textile-Reinforced Concrete Pub Date : 2008-03-01 DOI: 10.14359/20152
J. Hegger, S. Voss, A. Scholzen
{"title":"Textile-Reinforced Concrete for Light Structures","authors":"J. Hegger, S. Voss, A. Scholzen","doi":"10.14359/20152","DOIUrl":"https://doi.org/10.14359/20152","url":null,"abstract":"At present there is a rising interest of architects and engineers in the application of textile-reinforced concrete (TRC) as a construction material. Filigree, self-supporting and ventilated facade systems are state of the art in the application of TRC. In current investigations, potentials for light-weight structural members are developed. The required models for a secure design of structural members are deduced within the framework of the research activities in the collaborative research center 532 at RWTH Aachen University. The article outlines fundamental research results as well as their realization in first applications.","PeriodicalId":404712,"journal":{"name":"SP-251: Design & Applications of Textile-Reinforced Concrete","volume":"51 4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134517420","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Subsequently Applied Waterproof Basements Made of Textile Reinforced Concrete Using the Spraying Method 随后采用喷淋法对纺织钢筋混凝土防水地下室进行了应用
SP-251: Design & Applications of Textile-Reinforced Concrete Pub Date : 2008-03-01 DOI: 10.14359/20150
R. Mott, W. Brameshuber
{"title":"Subsequently Applied Waterproof Basements Made of Textile Reinforced Concrete Using the Spraying Method","authors":"R. Mott, W. Brameshuber","doi":"10.14359/20150","DOIUrl":"https://doi.org/10.14359/20150","url":null,"abstract":"Many regions in Germany show a rising groundwater level. Hence, the load case of buildings concerned changes from non-pressing to pressing water. Residential buildings not designed for the load case of pressing water have to be refitted. Conventional sealing methods are often associated with high complexity and high costs as well as the loss of living space. Furthermore, in many cases, they do not consider the additional static load of pressing water at all. This paper presents a newly developed, subsequently applied sealing against pressing water. It is made of textile-reinforced concrete. Using this composite material, it is possible to produce a sealing system with a wall thickness of about 30 to 35 mm (1.18 to 1.38 in.). During the production of an exhibit wall, it became apparent that the spraying technique is an adequate and practicable method to produce a subsequent sealing of textile reinforced concrete. Initial observations of the wall subjected to hydrostatic pressure reveal the application potential of this construction.","PeriodicalId":404712,"journal":{"name":"SP-251: Design & Applications of Textile-Reinforced Concrete","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130096003","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Textile Reinforced Concrete for Flexural Strengthening of RC-Structures-Part 2: Application on a Concrete Shell rc结构抗弯加固用纺织钢筋混凝土第2部分:混凝土外壳上的应用
SP-251: Design & Applications of Textile-Reinforced Concrete Pub Date : 2008-03-01 DOI: 10.14359/20149
S. Weiland, R. Ortlepp, B. Hauptenbuchner, M. Curbach
{"title":"Textile Reinforced Concrete for Flexural Strengthening of RC-Structures-Part 2: Application on a Concrete Shell","authors":"S. Weiland, R. Ortlepp, B. Hauptenbuchner, M. Curbach","doi":"10.14359/20149","DOIUrl":"https://doi.org/10.14359/20149","url":null,"abstract":"The first practical application of the innovative strengthening method using textile reinforced concrete was carried out in October/November 2006 in the retrofit of a reinforced-concrete roof shell structure at the University of Applied Sciences in Schweinfurt, Germany. Since textile-reinforced concrete had not yet been standardized as a construction material, a single “special-case” technical approval was sought from and granted by the appropriate authorities for this particular application of textile reinforced concrete. This strengthening method entailed the layer-by-layer application of three layers of fine-grained concrete and textile fabric comprising 800 tex carbon rovings onto a rough, sandblasted concrete surface. The resulting strengthening layer has a thickness of only 15 mm (0.6 in.) and extended the roof structure’s service life.","PeriodicalId":404712,"journal":{"name":"SP-251: Design & Applications of Textile-Reinforced Concrete","volume":"350 6","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132418489","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 22
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信