{"title":"An Overview of Heat Signature Technology and its Application to Proposed Concrete In-place Thermal Cracking Field Curing Indices","authors":"F. F. Radjy","doi":"10.14359/18654","DOIUrl":"https://doi.org/10.14359/18654","url":null,"abstract":"Heat of hydration and its rate play key roles in concrete thermal cracking and high-early strength development for fast track construction. Heat properties are also unique indicators of both the quality and the performance of cement, cementitious materials, and chemicals in concrete. Heat Signature is an automated method of measuring concrete heat of hydration and its rate, and adiabatic temperature rise and its rate versus concrete maturity (equivalent curing age at 68 °F). The measurements are performed on full size concrete specimens via the Internet/Intranet, and together with mixture information are saved to a database. Heat signature data in combination with simulation enable projecting concrete field performance in terms of its temperature, maturity, and strength profiles as a function of job site weather conditions and placement and curing plans. The paper reviews the underlying heat signature theory, its history, and reviews and interprets typical data from the many measurements in the US. To better index a given mix design’s field performance, a consistent set of thermal cracking and high-early curing age indices are introduced.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122875977","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Monitoring and Evaluation of Cement Hydration by Semi-Adiabatic Field Calorimetry","authors":"J. Sandberg, S. Liberman","doi":"10.14359/18648","DOIUrl":"https://doi.org/10.14359/18648","url":null,"abstract":"This paper describes the use of a recently developed, inexpensive portable semi-adiabatic calorimeter for monitoring cement hydration in concrete and mortar. The calorimeter measures the temperature as a function of time at the bottom of eight individual 3x6 cylinders with concrete or mortar. The measured temperature profile is used to evaluate the overall hydration performance of cementitious mixtures, with special emphasis on the timing and the size of the main hydration exotherms that strongly affect setting and early strength development of cementitious mixtures. Furthermore, a method has been developed for a more precise calculation of “thermal set”, with good correlation to manual set times according to ASTM C403. The field calorimeter is useful to screen the effect of type and dosage of admixtures and supplementary cementitious materials on “thermal” setting times in concrete and mortar.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127686820","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Use of Thermal Measurements to Detect Potential Incompatibilities of Common Concrete Materials","authors":"V. T. Cost, G. Knight","doi":"10.14359/18650","DOIUrl":"https://doi.org/10.14359/18650","url":null,"abstract":"Abnormal early hydration resulting from “incompatibilities” of common concrete materials can result in erratic set and strength gain behavior and associated finishing, curing, and cracking issues. Contributing influences include high temperatures, cement sulfate levels, Class C fly ash content, chemical admixture use, and design approaches for retardation of hot-weather concrete. Simple, expedient test methods are needed to identify potentially incompatible materials and conditions and to verify appropriate modifications to concrete proportions. Thermal measurements of the early heat development of materials mixtures in the laboratory (semi-adiabatic calorimetry) have been shown very useful toward this end. Abnormal set and strength development of field concrete was reproduced in laboratory paste and mortar mixtures and studied using thermal measurements, verified by parallel mortar cube strengths. Sensitivities of various contributing influences were documented in extensive testing. Changing one or more of the key material or mixture characteristics was usually successful in restoring normal behavior. Recommendations are presented for avoiding related field issues and for the use of calorimetry testing programs for diagnosis of such problems.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129454937","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modeling the Heat Development of Concrete Associated with Cement Hydration","authors":"C. V. Nielsen","doi":"10.14359/18653","DOIUrl":"https://doi.org/10.14359/18653","url":null,"abstract":"The maturity concept applying the Arrhenius equation is generally accepted as a proper way to model the temperature effects on concrete hardening. The Arrhenius equation gives the rate of hydration as a function of temperature depending on the activation energy for the cementitious binder materials. It is demonstrated how a simple three-parameter-model is sufficient to formulate the development of heat from the cement hydration process. Furthermore, the heat development is used to define the apparent degree of hydration. It is described how the heat of hydration may be determined experimentally at the concrete plant or in nearby concrete laboratories. By means of a semi-adiabatic container the heat released from the hydration process is monitored. Finally, examples of the practical applications of the heat of hydration data for various concrete mixtures are addressed. It is demonstrated how the use of admixtures may influence the heat of hydration and how difficult it is to model the complicated interactions between cement, mineral additions and admixtures without the use of experiments. The possibility of linking the heat of hydration data with the early-age mechanical properties is also illustrated.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"252 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116375432","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Characterization of Concrete Paving Mixtures with HIPERPAV","authors":"J. Ruiz, R. Rasmussen, T. Ferragut","doi":"10.14359/18652","DOIUrl":"https://doi.org/10.14359/18652","url":null,"abstract":"Concrete paving mixtures are subjected to varying climatic conditions during the hydration process. The temperature of the concrete is a function of the heat generated by the cement paste and climatic conditions as well as curing procedures applied during construction. Temperature development in the concrete is closely related to the development of concrete properties and also affects the generation of internal stresses in the pavement that if not properly controlled may result in cracking and other distresses. With the FHWA HIPERPAV software, it is possible to assess the impact on the performance of the pavement that different concrete materials will have by evaluating their heat of hydration properties (heat fingerprint) and their interaction with the environment. Characterization of concrete mixtures in terms of their heat of hydration allows for a more rational selection of materials as a function of the climatic conditions to which they are exposed. Selected concrete mixtures with this approach can thus provide more confidence in that they will perform satisfactorily under the site-specific conditions to which they are subjected effectively reducing potential excessive stresses in the pavement. In this paper, the system approach to characterize concrete paving mixtures and its effect under various climatic conditions is presented.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123899281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Online Prediction of Strength Development in Precast Production Based on Cement Reaction Model","authors":"E. Nordenswan, Aulis Kappi","doi":"10.14359/18656","DOIUrl":"https://doi.org/10.14359/18656","url":null,"abstract":"The throughput of precast concrete plants can be improved by controlled heating of the cast products. Presently many systems do measure maturity or degree-hours providing information about the strength development, but not sufficient data for accurate decisions for the control of heating. A heat control system has been developed based on an on-line predictive calculation of the temperature behavior of concrete and a maturity-strength model. The temperature is measured continuously and every minute a complete prediction calculation up to the target maturity and strength is made. If the target strength cannot be reached without heating by the target time limit, the system opens the valve for heating the mould, until the temperature is high enough. The predictive algorithm also provides an accurate estimation of the time when the prestress release or demoulding strength is going to be reached. The parameters for the cement heat generation model are obtained by semiadiabatic measurements of the production concrete. The system has been in use since 1999 and applied in over ten precast factories in Europe in hollow-core and railroad sleepers production. The system has reduced significantly the heating costs; reduced rejections caused by too early demoulding and improved production planning in the factories.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126780482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Jonathan L. Poole, K. Riding, K. Folliard, M. Juenger, A. Schindler
{"title":"Hydration Study of Cementitious Materials using Semi-Adiabatic Calorimetry","authors":"Jonathan L. Poole, K. Riding, K. Folliard, M. Juenger, A. Schindler","doi":"10.14359/18651","DOIUrl":"https://doi.org/10.14359/18651","url":null,"abstract":"Accurate characterization of the temperature rise in a concrete element requires an estimate of the adiabatic temperature rise of the concrete mixture. Semi-adiabatic calorimetry is commonly used to provide an estimate of the heat generation characteristics of a concrete mixture because of the relative simplicity of the test. This study examines the sources of variability in semi-adiabatic calorimetry, and an estimate of the confidence limits of the test is calculated. Then, twenty concrete mixtures are investigated using semi-adiabatic calorimetry. Activation energy values are calculated for each mixture using isothermal calorimetry. The adiabatic temperature rise is then calculated. The following mixture properties are investigated: cement type, cementitious content, water/cementitious material ratio, coarse aggregate type (siliceous river gravel and limestone), mixture placement temperature, and the effects of selected supplementary cementing materials. The following factors were the most important to reduce the adiabatic temperature rise: reduced cement content, use of a lower-heat cement, such as a Type V cement type, reduced aggregate specific heat, and substitution of cement with Class F fly ash.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123865707","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Riding, Jonathan L. Poole, M. Juenger, A. Schindler, K. Folliard
{"title":"Calorimetry Performed On-Site: Methods and Uses","authors":"K. Riding, Jonathan L. Poole, M. Juenger, A. Schindler, K. Folliard","doi":"10.14359/18649","DOIUrl":"https://doi.org/10.14359/18649","url":null,"abstract":"An accurate and practical method of determining the heat development of concrete mixtures under real mixing, cooling, hauling, placement, and curing conditions would greatly benefit contractors and engineers in helping predict in-place concrete member temperatures. Semi-adiabatic calorimetry was performed at several construction sites in temperature controlled rooms using concrete sampled from concrete placements. Semi-adiabatic calorimetry was also performed for comparison with concrete made under laboratory conditions from materials sampled at the respective batch plants. An energy balance-based finite difference method is presented for calculating the concrete non-linear heat generation using the measured heat of hydration determined from semi-adiabatic calorimetry. This method was used in a program which allows the direct input of values from semi-adiabatic calorimetry testing and estimates the development of in-place temperatures in mass concrete members of various geometries. Estimated concrete member temperatures are compared to the values measured on-site. Best practice suggestions are also given for performing semi-adiabatic calorimetry using concrete sampled on-site.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126922936","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"What Can We Learn From Monitoring Concrete Temperature?","authors":"P. Taylor","doi":"10.14359/18647","DOIUrl":"https://doi.org/10.14359/18647","url":null,"abstract":"There is a growing interest in monitoring the temperature of cement paste, mortar and concrete, particularly at early ages. However, there also seems to be confusion about what is being achieved by this activity, and what to do with the information once it is recorded. This paper outlines the tools and techniques in use, and discusses their applications, benefits and limitations. The discussion will cover concepts such as heat of hydration, maturity, isothermal calorimetry and semi-adiabatic temperature monitoring for assessing setting times, and potential incompatibility between the reactive ingredients (cements, supplementary cementitious materials, and chemical admixtures) in a mixture.","PeriodicalId":391820,"journal":{"name":"\"SP-241: Concrete Heat Development: Monitoring, Prediction & Management\"","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127755443","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}