{"title":"Properties of Tactile Sensors Based on Resistive Ink and the Dimension of Electrodes","authors":"J. Volf, V. Novák, V. Ryženko, S. Papezova","doi":"10.5772/intechopen.101210","DOIUrl":"https://doi.org/10.5772/intechopen.101210","url":null,"abstract":"This chapter presents the ongoing research, which aims to select suitable electrodes for their use in the pressure distribution measurement system Plantograf. In our research, we examine more materials, especially Yokohama conductive rubber CS57-7RSC and also conductive inks, which are represented type DZT-3 K, Graphit 33 and mixture of Loctite-Henkel conductive inks type Loctite 7004Hr and Loctite NCI 7002EC. All materials can be used as a converter between pressure and electrical quantities in the design of planar pressure transduces. We build on our previous works, where were examined the properties of conductive rubber, conductive inks and electrodes. Next part is focused on the newest results of our research. Due to the still incomplete results in the given issue, we decided to perform an extensive and original measurement of a total of 172 combinations of different electrode sizes, the ratio of conductive ink mixtures and the thickness of the applied ink layer. Thanks to this, it will be possible in the future to select a suitable combination of electrodes and inks when designing tactile pressure sensors for industrial or medical applications without the need to perform time-consuming preparatory measurements and exclude unsuitable ink-electrode combinations.","PeriodicalId":334258,"journal":{"name":"Applied Aspects of Modern Metrology [Working Title]","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115278662","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluation of the Long-Term Stability of Metrology Instruments","authors":"R. Coulon","doi":"10.5772/intechopen.100511","DOIUrl":"https://doi.org/10.5772/intechopen.100511","url":null,"abstract":"This chapter aims to emphasize the issue of the long-term stability of instruments used in metrology. This issue is a concern mentioned in the IEC/ISO17025:2017 standard and the JCGM100:2008 guide. Control charts are mentioned in these key documents as tools to assess whether a measurement process is under statistical control or not. Control charts (Shewhart charts, CUSUM chart, EWMA chart) are introduced and tested with simulated and real datasets from metrology instruments that operate at the ionizing department of the BIPM. The interest and the limits of such statistical analysis are discussed. They take their basis in a measurement model composed of Gaussian white noise. Although a measurement monitored over a relatively short period may be consistent with this model, it has been observed that the autocorrelation of the measurement data acquired over a long period limits the relevance of control charts. In this case, time series analysis seems more appropriate than conventional control charts. As an illustration, an optimal Bayesian smoother is introduced to demonstrate how to deconvolve the low-frequency random noise and refine the evaluation of uncertainty according to the measurement model for long-term measurement.","PeriodicalId":334258,"journal":{"name":"Applied Aspects of Modern Metrology [Working Title]","volume":"140 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123394454","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Calibration of Tanks and Ships’ Tanks for Storage and Transportation of Liquids by Laser Scanning","authors":"O. Samoilenko, V. Zaets","doi":"10.5772/intechopen.100565","DOIUrl":"https://doi.org/10.5772/intechopen.100565","url":null,"abstract":"The goal of the research is to improve the accuracy of measurement the volume and mass of oil and oil products by the stationary measuring tanks and ships’ tanks. It is possible to achieving this goal only by using the laser scanning at tanks calibration. Metrological and other technical requirements for laser scanners have been developed. It is proved by the results of mathematical modeling that only the compliance of scanners with the developed requirements makes it possible to achieve the set goal. It has been developed methods of measurements by laser scanners that allow to achieve an increase in the accuracy of determination the interval capacities of all types of the tanks. Methods, formulae and algorithms for interval capacities of tanks calculation are very complicated. Therefore, the interlaboratory comparisons for the interval capacities, calculated by laboratories own software developed for processing the results of the specified calibration are proposed. It is concluded that the developed requirements, methods and algorithms will allow, in several times, to increase the accuracy of determining the interval capacities of the tanks with a significant reduction in time for measurements and processing of their results.","PeriodicalId":334258,"journal":{"name":"Applied Aspects of Modern Metrology [Working Title]","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133179508","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Methodological Aspects of Using Comparators for Metrological Traceability of Instrument Transformers","authors":"V. Isaiev, Iurii Anokhin","doi":"10.5772/intechopen.100508","DOIUrl":"https://doi.org/10.5772/intechopen.100508","url":null,"abstract":"Instrument transformers are widely used in accounting the electricity as well as in protecting the energy generation systems. The accuracy of both voltage and current transformers is a critical parameter in terms of ensuring the reliability of functioning whether high-voltage or low-voltage networks. Two approaches are predominant in characterizing the voltage transformers with high primary rated voltage, these are applying either reference capacitor or reference transformer. Both methods require a device that enables the comparison of either two currents or two voltages. The errors of current transformers are determined by using the means of comparing two secondary currents, one of which is an output of reference transformer and the other is an output of a device under test. The calibration of such comparators may be a very sophisticated procedure. As metrological traceability depends on the measuring instruments and working standards used in calibration, the application of the proposed specific combinations of measuring instruments allows identifying the metrological traceability routes when calibrating the comparators.","PeriodicalId":334258,"journal":{"name":"Applied Aspects of Modern Metrology [Working Title]","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126824472","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Data Evaluation of Interlaboratory Comparisons for Calibration Laboratories","authors":"O. Velychko, T. Gordiyenko","doi":"10.5772/intechopen.99489","DOIUrl":"https://doi.org/10.5772/intechopen.99489","url":null,"abstract":"National accreditation agencies in different countries have set quite strict requirements for accreditation of testing and calibration laboratories. Interlaboratory comparisons (ILCs) are a form of experimental verification of laboratory activities to determine technical competence in a particular activity. Successful results of conducting ILCs for the laboratory are a confirmation of competence in carrying out certain types of measurements by a specific specialist on specific equipment. To obtain reliable results of ILC accredited laboratories, it is necessary to improve the methods of processing these results. These methods are based on various data processing algorithms. Therefore, it is necessary to choose the most optimal method of processing the obtained data, which would allow to obtain reliable results. In addition, it is necessary to take into account the peculiarities of the calibration laboratories (CLs) when evaluating the results of ILС. Such features are related to the need to provide calibration of measuring instruments for testing laboratories. The evaluation results for ILCs for CLs are presented. The results for all participants of ILCs were evaluated using the En and z indexes. The obtained results showed that for the such ILCs it is also necessary to evaluate the data using the z index also.","PeriodicalId":334258,"journal":{"name":"Applied Aspects of Modern Metrology [Working Title]","volume":"142 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132313658","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}