Leonardo Cecchetti, Tianshi Wang, T. Pfeiffer, W. Wieser, A. Steen, R. Huber, G. Soest, R. Huber
{"title":"Heartbeat optical coherence tomography enables accurate in vivo stents imaging: a quantitative image processing study (Conference Presentation)","authors":"Leonardo Cecchetti, Tianshi Wang, T. Pfeiffer, W. Wieser, A. Steen, R. Huber, G. Soest, R. Huber","doi":"10.1117/12.2513667","DOIUrl":"https://doi.org/10.1117/12.2513667","url":null,"abstract":"Intravascular optical coherence tomography (IV-OCT) provides micrometer-order resolution images for interventional guidance, visualizing artery wall geometry and composition. We developed an ultrafast IV-OCT system, called Heartbeat OCT, providing accurate imaging of a coronary artery by completing a scan during the filling phase between two consecutive ventricular contractions. In this study we aim to quantify the imaging accuracy of the Heartbeat OCT by comparing the stents imaging results with a commercial OCT and a micro-CT. \u0000\u0000Two metal stents (Biotronik Orsiro) were implanted in the LAD artery of two male pigs. After 28 days, in vivo images were acquired using Heartbeat OCT and a commercial OCT system (Ilumien Optis, St. Jude Medical). After sacrificing the pigs, we acquired ex vivo images of the stents using a micro-CT, creating reference datasets for comparison.\u0000\u0000We conducted quantitative image processing studies in three steps. We first manually segmented the stents in OCT images. In the second step, a reference planar reconstruction of the stents was created based on the micro-CT images. In the third step, we counted, for each OCT pullback, the percentage of stents pixels that are located at < 80 µm from the reference structure. \u0000\u0000The results show that, in the two images acquired with Heartbeat OCT, 60% and 49% of stent strut locations matched with the reference micro-CT data. In the data from the commercial OCT system 48% and 51% spots matched with the reference data. In conclusion, Heartbeat OCT shows an 3D geometric imaging accuracy comparable or superior to that of the commercial OCT.","PeriodicalId":323296,"journal":{"name":"Diagnostic and Therapeutic Applications of Light in Cardiology 2019","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130539161","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Real-time guidance of radiofrequency ablation catheter contact orientation with cardiac tissue using optical coherence tomography (Conference Presentation)","authors":"Xin Yu, Rajinder P. Singh-Moon, C. Hendon","doi":"10.1117/12.2510280","DOIUrl":"https://doi.org/10.1117/12.2510280","url":null,"abstract":"An important parameter that affects the quality of radiofrequency ablation lesions that are produced is the contact angle and contact orientation. Both are challenging to determine in vivo, and a method to classify that information and provide feedback in real time could potentially titrate the energy dose and increase the success rates of this treatment.\u0000\u0000In our work, a grin lens-terminated single mode fiber was integrated into a commercial RFA catheter to allow for M-mode OCT imaging at the catheter tip. Ventricular wedges were dissected from four fresh swine hearts and submerged in whole blood. M-mode imaging was performed in four different orientations: non-contact, 30 degrees, 60 degrees, and 90 degrees.\u0000\u0000One contact classifier with two sub-classifiers was developed to classify whether the catheter is in proper contact with the tissue and the angle of the catheter when it is in contact. This classifier is based on convolutional neural networks and used keras as developing framework with tensorflow backend.\u0000\u0000We achieved 98.51% accuracy in the \"contact\" or \"noncontact\" classifier and 91.21% in the orientation classifier with 30 degrees, 60 degrees and 90 degrees as outputs. We successfully tested the contact quality classifier in real time and achieved high accuracy in 0.0053 seconds for a group of 20 A-lines. These results support the potential of having the guidance of catheter placement during the RFA therapy using OCT image and pre-trained classifiers. Future experiments will further test M-mode OCT and our processing algorithm within a larger sample size and demonstrate the utility in vivo.","PeriodicalId":323296,"journal":{"name":"Diagnostic and Therapeutic Applications of Light in Cardiology 2019","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116313796","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Alba Alfonso García, A. Haudenschild, James McMasters, J. Bec, Xiangnan Zhou, A. Panitch, L. Griffiths, L. Marcu
{"title":"Fluorescence lifetime imaging and intravascular ultrasound (FLIm/IVUS) platform for label-free intraluminal characterization of vascular biomaterials in vitro and in vivo (Conference Presentation)","authors":"Alba Alfonso García, A. Haudenschild, James McMasters, J. Bec, Xiangnan Zhou, A. Panitch, L. Griffiths, L. Marcu","doi":"10.1117/12.2510816","DOIUrl":"https://doi.org/10.1117/12.2510816","url":null,"abstract":"","PeriodicalId":323296,"journal":{"name":"Diagnostic and Therapeutic Applications of Light in Cardiology 2019","volume":"4 6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116194616","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. Tshikudi, Olivier Simandoux, Dongkyun Kang, E. M. Cott, Michael N. Andrawes, D. Yelin, S. Nadkarni
{"title":"Evaluating fibrin polymerization dynamics in three dimensions peri-operatively in cardiac surgical patients using spectrally encoded confocal microscopy (SECM) (Conference Presentation)","authors":"D. Tshikudi, Olivier Simandoux, Dongkyun Kang, E. M. Cott, Michael N. Andrawes, D. Yelin, S. Nadkarni","doi":"10.1117/12.2510423","DOIUrl":"https://doi.org/10.1117/12.2510423","url":null,"abstract":"The polymerization dynamics and microstructure of the fibrin network is vital to hemostasis. During cardiac surgery, heparin is administered to prevent bleeding and reversed using protamine at the end of surgery. Residual heparin and inadequate reversal following surgery impair fibrin integrity, likely associated with major postoperative blood loss. In this study, we apply a recent approach, SECM, to evaluate fibrin integrity in blood clots during heparin administration and protamine reversal in cardiac surgery patients. SECM’s capability for video rate microscopy over large fields of view with a spatial resolution of 0.4x1.0µm permits the dynamic assessment of fibrin polymerization and 3D microstructure. Plasma from 10 patients was collected during cardiac surgery at baseline and following protamine reversal. In addition, the dose-dependent response of heparin was studied by spiking 6 normal plasma samples at heparin doses of 0.1-2USP/mL. All samples were tested using SECM and clot polymerization parameters including fibrin time (FT) and fibrin density (FD) were derived. In cardiac surgical patients, FD was lower after protamine reversal (p<0.05) compared to baseline despite similar FT, suggesting that fibrin microstructure is not restored immediately after surgery. In spiked samples, fibrin polymerization was delayed with higher FT (p<0.05), fibrin strands were longer, and the FD was lower (p<0.05) with increasing heparin dose. Similar to surgical samples, FD was not restored following protamine reversal (p<0.01) in spiked samples. These studies show that the loss of fibrin integrity following cardiac surgery can be quantified using SECM, which may provide new insights on mechanisms of postoperative bleeding.","PeriodicalId":323296,"journal":{"name":"Diagnostic and Therapeutic Applications of Light in Cardiology 2019","volume":"75 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121430230","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Cai Li, James McMasters, Alba Alfonso García, J. Bec, A. Haudenschild, A. Panitch, L. Griffiths, L. Marcu
{"title":"Study of vascular tissue grafts cellularization process in bioreactors using label-free fluorescence lifetime imaging (Conference Presentation)","authors":"Cai Li, James McMasters, Alba Alfonso García, J. Bec, A. Haudenschild, A. Panitch, L. Griffiths, L. Marcu","doi":"10.1117/12.2510823","DOIUrl":"https://doi.org/10.1117/12.2510823","url":null,"abstract":"","PeriodicalId":323296,"journal":{"name":"Diagnostic and Therapeutic Applications of Light in Cardiology 2019","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126892231","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Little, Radhika K. Poduval, Richard Caulfield, S. Noimark, R. Colchester, C. Loder, M. Tiwari, R. Rakhit, I. Papakonstantinou, AE Desjardins
{"title":"A hybrid approach of two-photon polymerization scaffold printing and microinjection of optically heterogenous material for the fabrication of vascular imaging phantoms (Conference Presentation)","authors":"C. Little, Radhika K. Poduval, Richard Caulfield, S. Noimark, R. Colchester, C. Loder, M. Tiwari, R. Rakhit, I. Papakonstantinou, AE Desjardins","doi":"10.1117/12.2508642","DOIUrl":"https://doi.org/10.1117/12.2508642","url":null,"abstract":"With intravascular Optical Coherence Tomography (IVOCT), phantom models are invaluable for system characterization and clinical training. However, accurately simulating 3D tissue geometries and heterogeneous optical properties has been challenging with phantom fabrication methods used to date. Anatomical phantom models typically require mesoscale structures integrated with heterogenous materials to simulate optical scattering and absorption by vascular tissue. In this study, we showed that two photon polymerisation (2PP) 3D printing offers the potential to generate complex tissue phantom scaffolds with sub-micron resolution (<200 nm), and that microinjection of tissue mimicking materials into these scaffolds allows for creation of realistic mesoscale anatomical phantom models of both healthy and diseased tissues. We developed three types of IVOCT phantom models: a free-standing wire model, a vessel side-branch model and an arterial plaque model. The free-standing wires ranged in diameter from 5 to 34 microns. Integration of tissue mimicking materials was performed using micropipettes with a tip diameter of 50 to 60 microns. Healthy vascular tissue was simulated using a mixture of PDMS, silicone oil and TiO2. Coconut oil was used to simulate a pathological lipid inclusion. All models were examined using optical microscopy and scanning electron microscopy, prior to imaging with a commercial IVOCT system. To our knowledge, this is the first phantom study to use 2PP 3D printing for OCT phantoms. The combination of optically-generated 3D scaffolds and microinjection of tissue mimicking materials will enable complex imaging phantoms for a wide range of microscopic and mesoscale optical imaging techniques.","PeriodicalId":323296,"journal":{"name":"Diagnostic and Therapeutic Applications of Light in Cardiology 2019","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127153264","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Nishimiya, O. Ahsen, Biwei Yin, Zhonglie Piao, Jiheun Ryu, Hany Osman, Gargi Sharma, H. Leung, Chia-Pin Liang, J. Gardecki, G. Tearney
{"title":"High-resolution micro-OCT for endothelial cell visualization in the coronary arteries\u0000 (Conference Presentation)","authors":"K. Nishimiya, O. Ahsen, Biwei Yin, Zhonglie Piao, Jiheun Ryu, Hany Osman, Gargi Sharma, H. Leung, Chia-Pin Liang, J. Gardecki, G. Tearney","doi":"10.1117/12.2506264","DOIUrl":"https://doi.org/10.1117/12.2506264","url":null,"abstract":"Coronary arteries are covered by a thin layer of endothelial cells (ECs). Impairment of ECs is at the origin of coronary atherosclerosis and its clinical manifestations. However, the study of ECs in humans remains elusive because of a lack of an imaging tool with sufficient resolution. We have developed a light-based 1-µm-resolution microscopic imaging technology termed micro-optical coherence tomography (µOCT) that can be implemented in a coronary catheter. In this study, we investigated the capability of µOCT to visualize EC morphology. We stripped the endothelium from 36 fresh swine coronary segments with cyanoacrylate glue. Histology showed that the stripping procedure successfully removed ECs from the swine coronary arteries. Coronary segments were then imaged in 3D with µOCT, and were processed for histology and scanning electron microscopy (SEM). µOCT images of stripped vs. intact sites were volume rendered in 3D and visually compared. 3D-µOCT allowed visualization of EC pavementing on intact artery surfaces that was strongly correlated to that seen by SEM. EC pavementing disappeared, and surface roughness calculated by computed root mean squared error diminished significantly at the sites with stripped EC compared with intact sites. µOCT was also utilized in human cadaver coronary arteries, showing its capability of identifying EC morphology of human coronary plaque harboring leukocyte adhesion, EC stent strut tissue coverage, and lack of ECs at lesions with necrotic core or superficial nodular calcifications. In conclusion, µOCT enables EC visualization in coronary arteries, suggesting that it could be useful in patients with coronary artery disease to better understand the role of ECs in the pathogenesis of coronary artery disease.","PeriodicalId":323296,"journal":{"name":"Diagnostic and Therapeutic Applications of Light in Cardiology 2019","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125616135","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}