SP-252: Health Monitoring Systems & Sensors for Assessing Concrete最新文献

筛选
英文 中文
Corrosion Monitoring of FRP Repaired Piles in Tidal Waters 潮汐水域玻璃钢修补桩腐蚀监测
K. Suh, R. Sen, G. Mullins, D. Winters
{"title":"Corrosion Monitoring of FRP Repaired Piles in Tidal Waters","authors":"K. Suh, R. Sen, G. Mullins, D. Winters","doi":"10.14359/20162","DOIUrl":"https://doi.org/10.14359/20162","url":null,"abstract":"This paper provides an overview of three different instrumentation schemes used to monitor long term performance of FRP repaired piles in tidal waters. These schemes were evaluated in four demonstration projects extending nearly five years. Two of these used linear polarization to estimate the corrosion rate while the third focused on the variation in the corrosion current. Problems associated with selection, installation and monitoring are described and representative results presented from all three systems. The results suggest data from linear polarization is more consistent. Findings indicate FRP wrapping lowers the prevailing corrosion rate.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114078517","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Spatial Imaging of Cracks in Fiber Reinforced Cementitious Composites by EIT 纤维增强胶凝复合材料裂纹的EIT空间成像
T. Hou, J. Lynch
{"title":"Spatial Imaging of Cracks in Fiber Reinforced Cementitious Composites by EIT","authors":"T. Hou, J. Lynch","doi":"10.14359/20157","DOIUrl":"https://doi.org/10.14359/20157","url":null,"abstract":"Cementitious materials are generally classified as semi-conductors that are capable of carrying electricity when an external electrical signal is applied. The electrical properties of cementitious materials have been widely explored for monitoring their internal hydration processes. However, comparatively less work has been done in using the inherent electrical properties of cementitious materials for structural health monitoring. In this study, the electrical properties of a unique strain-hardening fiber reinforced cementitious composite termed Engineered Cementitious Composite (ECC) are utilized for monitoring the performance and health of ECC structural components. Previous work has utilized two- and four-point probe techniques for measuring ECC bulk conductivity and illustrating the piezoresistive properties of the material. This work introduces electrical impedance tomography (EIT) as a powerful sensing methodology that measures the spatial distribution of conductivity over large areas of ECC elements. With a tomographic mapping of ECC conductivity, the distribution of strain fields and cracks in ECC elements can be observed in incredible visual detail.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125382668","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Nonlinear RC Structure Model Updating using Ambient Vibration Data 基于环境振动数据的非线性RC结构模型更新
Wei Song, M. So, S. Dyke, T. Harmon, G. Yun
{"title":"Nonlinear RC Structure Model Updating using Ambient Vibration Data","authors":"Wei Song, M. So, S. Dyke, T. Harmon, G. Yun","doi":"10.14359/20160","DOIUrl":"https://doi.org/10.14359/20160","url":null,"abstract":"A new method is proposed for updating the nonlinear finite element (FE) model of a structural system. It has been recognized that in some classes of structures, the degradation of the capacity of the structure occurs with a change in the zero-crossing stiffness. A relationship is obtained between the damage parameters used in a numerical simulation and the FE model stiffness at the zero-load crossings. This relationship is used to update the state of the FE model to reflect the damage that is associated with dynamic parameters. The modal characteristics are identified using ambient vibration data. The approach has been applied to a numerical model of a RC beam-column building subassemblage under quasi-static loading to demonstrate the proposed method. For simulation purposes, a one-dimensional hysteretic load-deformation material model is used in the FE model to represent the nonlinear moment-rotation behavior of RC beam-column joints. A modal flexibility-based model updating procedure is performed to update the damage parameters based on the change in the dynamic characteristics at each zero-load crossing. Good agreement between the updating and simulated stiffness demonstrates the efficacy of the proposed method.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132788971","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Electrical Property-Based Sensing of Concrete: Influence of Material Parameters on Dielectric Response 基于电性能的混凝土传感:材料参数对介电响应的影响
R. Manchiryal, N. Neithalath
{"title":"Electrical Property-Based Sensing of Concrete: Influence of Material Parameters on Dielectric Response","authors":"R. Manchiryal, N. Neithalath","doi":"10.14359/20155","DOIUrl":"https://doi.org/10.14359/20155","url":null,"abstract":"Electrical property based sensing of the properties of cement based materials is becoming increasingly popular. This paper reports the results of a systematic investigation carried out to understand the influence of material parameters on the dielectric response of cement pastes and concretes. A simple mathematical model that links the effective conductivity and time has been proposed, which can provide the setting time of the pastes. The variation in conductivity between plain and fly ash modified pastes is brought out. A fractional factorial experimental design coupled with range analysis is used to extract the significant parameters that influence the electrical conductivity of concretes. It is found that the aggregate-to-cementing materials ratio (a/cm) influences the very early age conductivity of concretes while the combinations of a/cm and water-to-cementing materials ratio (w/cm), and fly ash content and curing condition influences the final conductivity significantly. The changes in dielectric constant and conductivity spectra are attributed to the polarization phenomena. The dispersion in electrical conductivity starts at lower frequencies for fly ash modified pastes. There is an observed dielectric enhancement also for fly ash modified pastes. The dielectric response of concrete is very similar to that of pastes, and the effect of dilution by the aggregates in evident. The relaxation times of the cement pastes were determined from a geometric analysis of the bulk arc in the Nyquist plot. This method facilitates the determination of relaxation times and depression angle of the bulk arc using limited frequency sweep. The relaxation times decrease with increase in hydration time and conform to a power law. Though only a single relaxation time is considered in this study, the relaxation time distributions as represented by the depression angle, indicate increasing material heterogeneity with increasing hydration. Representing the dielectric constant at particular frequencies as a function of the capillary porosity in the cement pastes, it is possible to detect the percolation threshold of cement pastes. The observed percolation thresholds agree well with those reported for cement based materials.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128292052","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Structural Health Management of Concrete Structures using Wireless Sensors 基于无线传感器的混凝土结构健康管理
M. Gangone, M. Whelan, K. Janoyan
{"title":"Structural Health Management of Concrete Structures using Wireless Sensors","authors":"M. Gangone, M. Whelan, K. Janoyan","doi":"10.14359/20161","DOIUrl":"https://doi.org/10.14359/20161","url":null,"abstract":"Routine management and maintenance of civil infrastructure is undertaken based on structural health indicators from qualitative information gathered during inspections. The need to measure and collect data reflective of the true state of the infrastructure is crucial for proper management of the system. Presented in this paper are methods for incorporating field measurements for improved condition assessment. A full scale field deployment of a wireless, low-cost and automatic system for structural health management and condition assessment of highway structures is shown to demonstrate the ability of obtaining the necessary behavior characteristics. A short-span integral-abutment bridge was instrumented with a developed wireless sensor system measuring strain, in real time through a single network, monitoring the behavior of the structure under various loading conditions. Measurements validated the performance characteristics of the bridge, including transverse moment distribution, end fixity, and composite action of the girders and bridge deck.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122294388","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Structural Health Monitoring Potential using a Long Period Grating-Based Humidity Sensor 基于长周期光栅湿度传感器的结构健康监测电位
T. Venugopalan, M. Rajesh, T. Sun, K. Grattan
{"title":"Structural Health Monitoring Potential using a Long Period Grating-Based Humidity Sensor","authors":"T. Venugopalan, M. Rajesh, T. Sun, K. Grattan","doi":"10.14359/20159","DOIUrl":"https://doi.org/10.14359/20159","url":null,"abstract":"In this research, a series of innovative optically-based sensors, which were designed, fabricated and characterized were created for potential evaluation for applications in determining moisture ingress in a range of concrete materials subjected to various environmental conditions. The approach taken to the creation of these novel humidity sensors is using long period grating (LPG) technology in an optical fiber. Several sensor configurations are fabricated by coating LPGs and then characterizing and cross-comparing and evaluating the resulting sensor performance. The thin layer of polyvinyl alcohol (PVA), whose refractive index varies as a function of humidity level when coated onto a LPG written into an optical fiber, provides a means to change the optical propagation in the fiber and thus to induce the a wavelength shift in the attenuation bands of its transmission spectrum, which then is calibrated against the measured, humidity. When compared to the more familiar optical fiber-based humidity sensors, using Fiber Bragg gratings (FBGs), the LPG-based devices show a much higher measurement sensitivity, with more relaxed requirements for coating thickness and uniformity.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"138 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133096987","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Parameters Affecting the Measurements of Embedded Electrical Sensors for Concrete Health Monitoring Applications 影响混凝土健康监测应用中嵌入式电传感器测量的参数
Farsad Rajabipour, J. Weiss
{"title":"Parameters Affecting the Measurements of Embedded Electrical Sensors for Concrete Health Monitoring Applications","authors":"Farsad Rajabipour, J. Weiss","doi":"10.14359/20154","DOIUrl":"https://doi.org/10.14359/20154","url":null,"abstract":"signs of aging and deterioration. In comparison, the sensor-based health monitoring shows several advantages including increased accuracy and frequency of the measurements, possibility of remote sensing, and ability to determine the rate of damage and remaining life of a structure. Several sensors have been developed to monitor the durability of concrete. Among these, a series of electrical/electro-chemical sensors have been recently introduced that enable measuring the transport properties of concrete as well as monitoring the corrosion process of the reinforcing steel. In this paper, several types of such electrical sensors are introduced and the theoretical background behind each measurement is discussed. For example, it is shown that measurement of the electrical conductivity of concrete can be used to estimate the permeability, ion diffusivity, or moisture content of concrete. Although the embedded electrical sensors provide valuable measurements enabling prediction of concrete durability, proper calibration of the measurements is essential. As an example, the electrical conductivity measurements of concrete are shown to be simultaneously influenced by four parameters: (a) concrete microstructure, (b) pore fluid composition, (c) moisture content, and (d) temperature. Experimental evidence is provided suggesting that the sensor measurements must be calibrated to account for these parameters; otherwise, the results can be misleading. A combination of several sensors can provide the information needed for proper calibration of the measurements.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125103513","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Calibration of Optical Fiber Refractive Index Sensor with Potential for Structural Corrosion Monitoring 具有结构腐蚀监测潜力的光纤折射率传感器的标定
C. Lam, M. Rajesh, T. Sun, K. Grattan, S. Grattan, Susan E. Taylor, P. Basheer
{"title":"Calibration of Optical Fiber Refractive Index Sensor with Potential for Structural Corrosion Monitoring","authors":"C. Lam, M. Rajesh, T. Sun, K. Grattan, S. Grattan, Susan E. Taylor, P. Basheer","doi":"10.14359/20158","DOIUrl":"https://doi.org/10.14359/20158","url":null,"abstract":"There is a need in industry for new devices for the monitoring of chloride ion ingress in structural concrete. This work reports on the development of a reflective, gold-coated long period grating-based sensor for the measurement of chloride ions in solution, with potential for evaluating the corrosion condition of concrete structures. The sensor scheme is based around a long period fiere grating (LPG)-based Michelson interferometer where the sensor was calibrated and evaluated in the laboratory using sodium chloride solutions, over a wide range of concentrations, from 0.01 M to 4.00 M. The grating response yields shifts in the spectral characteristic of the interferometer, due to the change of refracting index of the solution surrounding it. It was found that the sensitivity of the device could be enhanced over that obtained from a bare fiber by coating the LPG-based interferometer with gold nanoparticles.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131933371","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Embedded Sensors for Measuring Environmental Parameters in Concrete 用于测量混凝土环境参数的嵌入式传感器
D. Lange, Z. Grasley, R. Rodden
{"title":"Embedded Sensors for Measuring Environmental Parameters in Concrete","authors":"D. Lange, Z. Grasley, R. Rodden","doi":"10.14359/20156","DOIUrl":"https://doi.org/10.14359/20156","url":null,"abstract":"Environmental factors are major considerations of health monitoring of structures. A new system has been developed for measuring the internal relative humidity and temperature in concrete laboratory specimens and field structures. Internal relative humidity measurements in concrete are useful for evaluating shrinkage stress development and assessing structural susceptibility to durability problems. This paper describes the system, presents the essential elements of analysis that relates RH to internal stress in porous materials, and presents field applications that shows how environment data can facilitate analysis of stress and deformation of pavement. The new system has been used in laboratory and field experiments. Advantages of the new system are summarized. Some problems encountered in measuring relative humidity, especially in the field, are discussed.","PeriodicalId":322977,"journal":{"name":"SP-252: Health Monitoring Systems & Sensors for Assessing Concrete","volume":"101 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126373964","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书