{"title":"Automatic segmentation of intravascular ultrasound images based on temporal texture analysis","authors":"Chi Hau Chen, Adithya G. Gangidi","doi":"10.1142/9789811211072_0014","DOIUrl":"https://doi.org/10.1142/9789811211072_0014","url":null,"abstract":"In our study we developed a novel automatic algorithm for the analysis and delineation of lumen and external elastic membrane (EEM) boundaries using both temporal and spatial variation of IVUS data. The pre-processing steps involve the construction of Laplacian gradient image from neighboring images, and the use of discrete wavelet frame decompositions for texture computation. A smooth Lumen and EEM contour is predicted by applying radial basis functions on contour initialization. This algorithm is evaluated on large data set of multi-patient 2293 IVUS images and pitted against the manually segmented contours by medical experts. It is observed that this algorithm reliably performs contour prediction with clinically appreciated limits of average prediction error equaling 0.1254 mm and 0.0762 mm for Lumen and EEM respectively. Furthermore a custom Lumen detection algorithm for stented images is proposed and tested with average prediction error of 0.048 mm.","PeriodicalId":320986,"journal":{"name":"Computing in Cardiology 2014","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122949813","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. Hernando, R. Bailón, R. Almeida, Alfredo I. Hernández
{"title":"QRS detection optimization in stress test recordings using evolutionary algorithms","authors":"D. Hernando, R. Bailón, R. Almeida, Alfredo I. Hernández","doi":"10.26754/JJI-I3A.201401652","DOIUrl":"https://doi.org/10.26754/JJI-I3A.201401652","url":null,"abstract":"QRS detection in exercise stress test recordings remains a challenging task, because they are highly non-stationary and contaminated with noises, such as large baseline wander and muscular noise, among others. The aim of this work is to find an optimal set of parameters for QRS detection in very noisy ECG signals, such as those acquired during stress tests. Parameter optimization was addressed by an evolutionary algorithm. A training database was created using 48 ECG recordings with reference QRS complexes. Each ECG recording is artificially contaminated with 3 types of real noise. A cost function combining the detection error probability, the mean detection jitter, and its standard deviation was defined, in order to obtain a quantitative performance evaluation of the detector. Evaluation was performed on an exercise stress test database composed of 54 real ECG recordings, with annotated QRS. The detector was configured with default parameter values, and also with the optimal values obtained from the evolutionary algorithm. The QRS detector with its optimized parameters showed a mean improvement of 4.6% compared to its performance with the default parameters. Furthermore, the use of optimized parameters led to at least the same performance than the initial parameters for all records, and the improvement was higher (up to 19.36 %) in noisy records, demonstrating the advantages of the optimized parameters in noisy environments.","PeriodicalId":320986,"journal":{"name":"Computing in Cardiology 2014","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132323342","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
F. Maffessanti, K. Addetia, G. Murtagh, L. Weinert, Amit R. Patel, R. Lang, V. Mor-Avi
{"title":"Fusion imaging of computed tomography and 3D echocardiography: Combined assessment of coronary anatomy and myocardial function","authors":"F. Maffessanti, K. Addetia, G. Murtagh, L. Weinert, Amit R. Patel, R. Lang, V. Mor-Avi","doi":"10.1016/S0735-1097(14)61101-3","DOIUrl":"https://doi.org/10.1016/S0735-1097(14)61101-3","url":null,"abstract":"","PeriodicalId":320986,"journal":{"name":"Computing in Cardiology 2014","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2014-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126921292","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}