S. H. Sajjad, K. Shahzad, Tasawar Iqbal, N. Ashraf
{"title":"Impact of urban evolution on local temperature trends of Rawalpindi and Islamabad","authors":"S. H. Sajjad, K. Shahzad, Tasawar Iqbal, N. Ashraf","doi":"10.34154/2020-ejcc-0202-33-46/euraass","DOIUrl":"https://doi.org/10.34154/2020-ejcc-0202-33-46/euraass","url":null,"abstract":"Rawalpindi and Islamabad commonly known as twin cities of Pakistan have 3.2 million population. Twin cities have rapidly urbanized in the last three decades. The objective of the present study is to compute the urban growth and its effect on evolution of local temperature trends of twin cities. To compute the land-cover change such as built-up area, vegetation cover, water and barren land, Landsat images of 1980, 1992, 2000 and 2013 are classified by using the supervised image classification with maximum likelihood rule and probability surface method. To evaluate the change in temperature trends, homogenized time series data of daily averaged monthly minimum (Tmin) and maximum (Tmax) temperatures for the period of 1983 to 2013 is analyzed by using the linear regression. The results show that built-up area of twin cities increased from 66 km2 in 1983 to 148 km2 in 2013 with an increase of 120 per cent within 31 years. Due to resulted urbanization, Tmin and Tmax of twin cities have been increasing. Tmin is increased more in Rawalpindi than Islamabad and Tmax is increased more in Islamabad than Rawalpindi. The highest increase in Tmin and Tmax at both stations is observed during spring season.","PeriodicalId":259587,"journal":{"name":"European Journal of Climate Change","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117155954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Thermal comfort level in Chennai Metropolis under present and future climate scenarios","authors":"Anushiya Jeganathan, R. Andimuthu, P. Kandasamy","doi":"10.34154/2019-EJCC-0101-13-23/EURAASS","DOIUrl":"https://doi.org/10.34154/2019-EJCC-0101-13-23/EURAASS","url":null,"abstract":"Climate change poses unprecedented challenges to urban inhabitants. Thermal comfort is one of the major issues in cities and it is expected to change in future due to climate change. The change of climate parameters particularly, temperature and relative humidity will affect the thermal comfort environments of people. Discomfort levels are largely preventable and requires prior assessment. In this study, the observed and projected thermal comfort level of Chennai Metropolis are calculated using Thermo-Hygrometric Index (THI) under present and future climate scenarios. The observed climate data of Chennai Metropolis for the period 1951-2010 procured from IMD are used to find the long term changes in observed thermal comfort. Monthly trends of THI are calculated for different periods to understand the thermal comfort behaviour in recent decades. On long term observation, high discomfort level is noticed during May and June months followed by July, August, April and September months. While there is a sharp increase in THI during winter months of recent decades. There is a considerable increase in discomfort level notice in post-monsoon season especially in December and November months. Future THI is calculated using high-resolution future climate scenarios developed using PRECIS. The deviations of THI from baseline to mid-century (2041-2070) and end-century period (2071-2099) are calculated and geospatially mapped using ArcGIS. There would be 2.0°C increase of THI is expected during winter and post monsoon months in mid-century scenario. Changes in future THI warrants the need for better cooling requirements and city planning to adapt with the future trends of external environment. Thus the study urges urban planners to evolve climate smart adaptation strategies to provide the congenial climate for a better living.","PeriodicalId":259587,"journal":{"name":"European Journal of Climate Change","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130628049","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Dang Nguyen Dong Phuong, Dang Kien Cuong, Duong Ton Dam, N. K. Loi
{"title":"Long–term spatio–temporal warming tendency in the Vietnamese Mekong Delta based on observed and high–resolution gridded datasets","authors":"Dang Nguyen Dong Phuong, Dang Kien Cuong, Duong Ton Dam, N. K. Loi","doi":"10.34154/2019-EJCC-0101-01-16/EURAASS","DOIUrl":"https://doi.org/10.34154/2019-EJCC-0101-01-16/EURAASS","url":null,"abstract":"The Vietnamese Mekong Delta is among the most vulnerable deltas to climate–related hazards across the globe. In this study, the annual mean and extreme temperatures from 11 meteorological stations over the Vietnamese Mekong Delta were subjected to normality, homogeneity and trend analysis by employing a number of powerful statistical tests (i.e. Shapiro–Wilk, Buishand Range test, classical/modified Mann–Kendall test and Sen’s slope estimator). As for spatio–temporal assessment, the well–known (0.5° × 0.5°) high–resolution gridded dataset (i.e. CRU TS4.02) was also utilized to examine trend possibilities for three different time periods (i.e. 1901–2017, 1951–2017 and 1981–2017) by integrating spatial interpolation algorithms (i.e. IDW and Ordinary Kriging) with statistical trend tests. Comparing the calculated test–statistics to their critical values (a = 0.05), it is evident that most of the temperature records can be considered to be normal and non–homogeneous with respect to normality and homogeneity test respectively. As for temporal trend detection, the outcomes show high domination of significantly increasing trends. Additionally, the results of trend estimation indicate that the magnitude of increase in minimum temperature was mostly greater than mean and maximum ones and the recent period (1981–2017) also revealed greater increasing rates compared to the entire analyzed period and second half of the 20th century. In general, these findings yield various evident indications of warming tendency in the Vietnamese Mekong Delta over the last three decades.","PeriodicalId":259587,"journal":{"name":"European Journal of Climate Change","volume":"277 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127135693","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Monitoring and analysis of urban heat Island of Lahore city in Pakistan during winter season","authors":"","doi":"10.34154/2019-ejcc-0101-24-31/euraass","DOIUrl":"https://doi.org/10.34154/2019-ejcc-0101-24-31/euraass","url":null,"abstract":"The phenomenon of Urban Heat Island (UHI) is a result of various factors ranging from increase in urban built-up land to human activities and affected the climate in urban areas. Therefore, the main objectives of the current study are to monitor the temperature variations and assess UHI in Lahore city. In order to measure the UHI, the meteorological data was collected by installing Digital Weather Station WS-1080, at two selected sites, one at Mozang (urban site) and other at Sangra (rural site) from January 15 to 18, 2015 (4 days) in winter season. The results of the study reveal that notable variations of temperature were recorded between Mozang and Sangra. The mean day-time temperature (23.9°C) was higher at Sangra than Mozang (22.8°C). Whereas temperature at night-time was higher at Mozang and lower at Sangra. The R2 value of 0.0041 also demonstrates positive relationship between UHI and dew point at Mozang. The speed and direction of wind also influences the intensity of UHI. During the observational days, the range of UHI was 4.3°C to 6.2°C. Hence, the difference between the minimum and maximum temperature was almost 2°C and it highlighted that the UHI was enhancing. Lastly, few suggestions were proposed to mitigate the issue of UHI.","PeriodicalId":259587,"journal":{"name":"European Journal of Climate Change","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124426988","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Mohd Khairul Idlan Muhammad, Mohamad Rajab Houmsi, Ghaith Falah Ziarh, M. Noor, T. Ismail, S. Harun
{"title":"A two-stage bias correction approach for downscaling and projection of daily average temperature","authors":"Mohd Khairul Idlan Muhammad, Mohamad Rajab Houmsi, Ghaith Falah Ziarh, M. Noor, T. Ismail, S. Harun","doi":"10.34154/2019-EJCC-0101-32-37/EURAASS","DOIUrl":"https://doi.org/10.34154/2019-EJCC-0101-32-37/EURAASS","url":null,"abstract":"Reliable projection of climate is essential for climate change impact assessment and mitigation planning. General Circulation Models (GCMs) simulations are generally downscaled into much finer spatial resolution for climate change impact studies at local and regional scales. The objective of the present study is to use a two-stage bias correction approach for downscale and project future changes of daily average temperature. The approach was applied for downscaling and projection of daily average temperature of Senai meteorological station located in Johor Bahru, Malaysia using a GCM of Coupled Model Intercomparison Project Phase 5 (CMIP5) under four representative concentration pathways (RCP) scenarios. The two-stage bias correction method was based on correction in mean factor and variability inflation factor. The model performances were assessed using different statistical measures including mean bias error (MBE), mean absolute error (MAE), root mean square error (RMSE), index of agreement (MD), Nash–Sutcliffe model efficiency (NSE) and coefficient of determination (R2). Results showed that the downscaling method could simulate historical daily average temperature at the station very well. The GCM projected an increase in daily average temperature by 1.4ºC, 2.2ºC, 2.5ºC, and 3.4ºC under RCP2.6, RCP4.5, RCP6.0 and RCP8.5 scenarios, respectively in the end of this century. It is expected that the finding of the study would help in climate change impact assessment and adopting necessary adaptation measures.","PeriodicalId":259587,"journal":{"name":"European Journal of Climate Change","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130609798","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}