{"title":"Distillation Column","authors":"N. Ramli","doi":"10.5772/intechopen.74656","DOIUrl":"https://doi.org/10.5772/intechopen.74656","url":null,"abstract":"Dynamic simulations are used to model systems that are in transition from a steady state to dynamic state. The dynamic model is used to evaluate different basic control schemes and later to evaluate and test the control strategy. In this chapter, a steady-state simula- tion and dynamic simulation for debutanizer column are performed using a plant pro cess simulator, HYSYS™. The objective of this chapter is to study the process variables of each controller at the column by using different tuning relations and identify the best tuning methods for the controllers in order to optimise the performance of the column. Two tuning methods are used in determining the controller settings for each controller. The process variable for each controller are used by using two different tuning meth - ods are being studied. Furthermore, the effect on the process variables of each controller when using the controller settings based on real plant data and calculated using the PID equation is also being analysed. As for conclusion, the different tuning methods could give the different results on the behaviour of the response for each controller and the optimum response for each controller could be determined by considering the behaviour of the response and the value of integral square of the error (ISE) and integral of absolute value of error (IAE). All the research and findings obtained will be used to improve the overall performance of the plant as well as to improve the quality of the product and maximise profitability. The successful outcome of this chapter will be a great helping hand for industrial application. for specific The response of the could be decided in terms of the responsiveness of the to the required the degree to which the controller overshoots the setpoint and the degree of oscillation. The use of the PID algorithm for does not guarantee optimal control of the and stability.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"74 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133968712","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Data-Based Tuning of PID Controllers: A Combined Model- Reference and VRFT Method","authors":"J. Jeng","doi":"10.5772/INTECHOPEN.75835","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.75835","url":null,"abstract":"This chapter presents a novel data-based proportional-integral-derivative (PID) control- ler tuning method that can be applied to stable, integrating, and unstable plants. The tuning method is developed under the virtual reference feedback tuning (VRFT) design framework, where the reference model of VRFT is coordinately optimized with the controller on the basis of the model-reference (MR) criterion to ensure the validity of the VRFT approach. In the proposed MR-VRFT method, a set of closed-loop plant data are directly exploited without resorting to a process model. Because of its closed-loop tuning capability, the MR-VRFT method can be applied online to improve (retune) existing underperforming controllers. Moreover, the tuning method includes a robust- ness specification based on the maximum sensitivity that enables the designer to explic-itly address the trade-off between performance and robustness. Simulation studies, including the application to an unstable biochemical reactor, are presented to demonstrate the effectiveness of MR-VRFT method.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123316853","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Urrea-Quintero, Jesús-Antonio Hernández-Riveros, N. Muñoz-Galeano
{"title":"Optimum PI/PID Controllers Tuning via an Evolutionary Algorithm","authors":"J. Urrea-Quintero, Jesús-Antonio Hernández-Riveros, N. Muñoz-Galeano","doi":"10.5772/INTECHOPEN.74297","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.74297","url":null,"abstract":"In this chapter, it is demonstrated that when using advanced evolutionary algorithms, whatever the adopted system model (SOSPD, nonminimum phase, oscillatory or nonlinear), it is possible to find optimal parameters for PID controllers satisfying simultaneously the behavior of the system and a performance index such as absolute integral error (IAE). The Multidynamics Algorithm for Global Optimization (MAGO) is used to solve the control problem with PID controllers. MAGO is an evolutionary algorithm without parameters, with statistical operators, and for the optimization, it does not need the derivatives, what makes it very effective for complex engineering problems. A selection of some representative benchmark systems is carried out, and the respectively twodegree-of-freedom (2DoF) PID controllers are tuned. A power electronic converter is adopted as a case study and based on its nonlinear dynamical model, a PI controller is tuned. In all cases, the control problem is formulated as a constrained optimization problem and solved using MAGO. The results found are outstanding.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121202626","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Maximum Peak-Gain Margin (Mp-GM) Tuning Method for Two Degree of Freedom PID Controller","authors":"J. P. Sutikno, Nur Hidayah, R. Handogo","doi":"10.5772/INTECHOPEN.74293","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.74293","url":null,"abstract":"The specification of controller setting for a standard controller typically requires a trade-off between set point tracking and disturbance rejection. For this reason, two simple strategies can be used to adjust the set point and disturbance responses independently. These strate- gies are referred as controllers that have two degree of freedom. Unfortunately, the tuning parameters of the model uncertainty at two degree of freedom structure controller are difficult to obtain. Maximum peak-gain margin (Mp-GM) tuning method has been intro-duced to obtain the setting parameters of two degree of freedom structure controller based on model uncertainty. This tuning method is able to obtain reasonable controller parameters even under process uncertainties on standard two degree of freedom IMC. This research was conducted to develop maximum peak-gain margin tuning method for another two degree of freedom structure controller such as two degree of freedom IMC by Kaya [9] and two degree of freedom PID. The simulation results show that the maximum peak-gain margin tuning method can give a good target set point tracking, disturbance rejection, and robustness in two degree of freedom structure controller system.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121428891","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PID Control for Takagi-Sugeno Fuzzy Model","authors":"Taieb Adel, Chaari Abdelkader","doi":"10.5772/INTECHOPEN.74295","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.74295","url":null,"abstract":"In this chapter, we deal with the problem of controlling Takagi-Sugeno (TS) fuzzy model by PID controllers using the particle swarm optimization (PSO). Therefore, a new algorithm is proposed. This algorithm relies on the use of a new objective function taking into account both the performance indices and the error signal. The advantages of this approach are discussed through simulations on a numerical example.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123853879","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Advanced Methods of PID Controller Tuning for Specified Performance","authors":"Š. Bucz, A. Kozáková","doi":"10.5772/INTECHOPEN.76069","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.76069","url":null,"abstract":"This chapter provides a concise survey, classification and historical perspective of practiceoriented methods for designing proportional-integral-derivative (PID) controllers and autotuners showing the persistent demand for PID tuning algorithms that integrate performance requirements into the tuning algorithm. The proposed frequency-domain PID controller design method guarantees closed-loop performance in terms of commonly used time-domain specifications. One of its major benefits is universal applicability for both slow and fast-controlled plants with unknown mathematical model. Special charts called B-parabolas were developed as a practical design tool that enables consistent and systematic shaping of the closed-loop step response with regard to specified performance and dynamics of the uncertain controlled plant.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"231 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127043585","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Constraint Handling Optimal PI Controller Design for Integrating Processes: Optimization-Based Approach for Analytical Design","authors":"R. Tchamna, Moonyong Lee","doi":"10.5772/INTECHOPEN.74301","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.74301","url":null,"abstract":"This chapter introduces the closed-form analytical design of proportional-integral (PI) controller parameters for the optimal control subjected to operational constraints. The main idea of the design is not only to minimize the control performance index but also to cope with the constraints in the process variable, controller output, and its rate of change. The proposed optimization-based approach is examined to regulatory and servo control of integrating processes with three typical operation constraints. To derive an analytical design formula, the constrained optimal control problem in the time domain was transformed to an unconstrained optimization in a new parameter space associated with closed-loop dynamics. By taking the advantage of the proposed analytical approach, the optimal PI parameters can be found quickly based on the graphical analysis without complex numerical optimization. The resulting optimal PI controller guarantees the glob- ally optimal closed-loop response and handles the operational constraints precisely.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116402584","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. R. Melo, Nathalia Arthur Brunet Monteiro, Danilo Pequeno, J. J. Silva, J. Neto
{"title":"Decoupling Control and Soft Sensor Design for an Experimental Platform","authors":"T. R. Melo, Nathalia Arthur Brunet Monteiro, Danilo Pequeno, J. J. Silva, J. Neto","doi":"10.5772/INTECHOPEN.75708","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.75708","url":null,"abstract":"This chapter presents the design and implementation of a decoupling control strategy for an experimental platform and pilot plant, dedicated to the study of the fouling phenomena which occur in industrial tubes. Initially, a set of tests was done for the identification and validation of FOPDT models suitable to the four processes of the multivariable system: flow-voltage, flow-current, pressure-voltage, and pressure-current. After, the interaction between the inputs and outputs of the system was analyzed by the RGA and RNGA matrices. The static decoupling and decentralized PID controllers tuned by the Ziegler-Nichols and IMC methods were designed. Then, the set point tracking response was simulated and implemented using MATLAB and LabVIEW software, respectively. Finally, the concept of soft sensor was applied to monitor the output variables of the experimental platform, for a better performance of the decoupling control.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121861216","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"PID Controller Design Methods for Multi-Mass Resonance System","authors":"H. Ikeda","doi":"10.5772/INTECHOPEN.74298","DOIUrl":"https://doi.org/10.5772/INTECHOPEN.74298","url":null,"abstract":"Motor drive systems are indispensable for applications in the industrial field. High-speed and high-accuracy control is required for motor drive systems. However, solutions to meet these requirements can cause mechanical resonance vibrations to occur in the system as a result of miniaturization and system weight reduction. It is therefore necessary to model these systems as multi-mass resonance systems with multiple masses and finite rigid shafts, gears, and loads. In addition, vibration suppression control should be applied to these systems. This chapter provides two off-line tuning methods for a digital proportional-integral-derivative (PID)-type controller for a two-mass resonance system to suppress its mechanical resonance vibrations. These methods include a coefficient dia- gram method and a fictitious reference iterative tuning method. The former method uses a nominal mathematical model of the object while the latter method uses only the initial experimental data without use of the mathematical model. In this chapter, the two methods are compared. A controller is proposed that consists of a modified integral- proportional derivative (I-PD) speed controller and a proportional-integral (PI) current controller, and requires no information about the load side state variables. Finally, the effectiveness of the proposed method is confirmed through computer simulations and experimental results.","PeriodicalId":205138,"journal":{"name":"PID Control for Industrial Processes","volume":"439 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122129058","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}