Open Access Research in Anatomy最新文献

筛选
英文 中文
Sex Differences in Histomorphology of the Human Carotid Body 人颈动脉体组织形态学的性别差异
Open Access Research in Anatomy Pub Date : 2018-06-20 DOI: 10.31031/oara.2018.02.000531
Johnstone M Muthoka
{"title":"Sex Differences in Histomorphology of the Human Carotid Body","authors":"Johnstone M Muthoka","doi":"10.31031/oara.2018.02.000531","DOIUrl":"https://doi.org/10.31031/oara.2018.02.000531","url":null,"abstract":"","PeriodicalId":196515,"journal":{"name":"Open Access Research in Anatomy","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132309088","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Innovative Surgical Technique in the Management of Vallecular Cyst 治疗小静脉囊肿的创新外科技术
Open Access Research in Anatomy Pub Date : 2018-06-13 DOI: 10.31031/OARA.2018.02.000530
M. Saroch, R. Sharma, A. Saini
{"title":"Innovative Surgical Technique in the Management of Vallecular Cyst","authors":"M. Saroch, R. Sharma, A. Saini","doi":"10.31031/OARA.2018.02.000530","DOIUrl":"https://doi.org/10.31031/OARA.2018.02.000530","url":null,"abstract":"","PeriodicalId":196515,"journal":{"name":"Open Access Research in Anatomy","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130692145","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Contribution of Elecromyographic Examination to Neuro-Occlusal Rehabilitation 肌电图检查对神经咬合康复的贡献
Open Access Research in Anatomy Pub Date : 2018-06-07 DOI: 10.31031/OARA.2018.02.000529
Amel Belkhiri
{"title":"Contribution of Elecromyographic Examination to Neuro-Occlusal Rehabilitation","authors":"Amel Belkhiri","doi":"10.31031/OARA.2018.02.000529","DOIUrl":"https://doi.org/10.31031/OARA.2018.02.000529","url":null,"abstract":"For Pedro Planas, the indirect tracks allow, in addition to the treatment of certain malocclusions, to release laterality movements and thus increase the activity of the masticatory muscles. The objective of this work will be to observe the effect of the Planas device on the activity of the masseter and temporal anterior, on each side, during right and left lateral movements. An electromyogram is used to assess the bioelectrical activity of these muscles with and without tracks in place. Figure 1: Plates with tracks or indirect tracks of Planas. Open Acc Res Anatomy Copyright © Amel Belkhiri 2/5 How to cite this article: Amel B. Contribution of Elecromyographic Examination to Neuro-Occlusal Rehabilitation.Open Acc Res Anatomy. 2(1). OARA.000529.2018. DOI: 10.31031/OARA.2018.02.000529 Volume 2 Issue 1 The control group is represented by the same patients, without the Planas plates. The electromyogram used for this work is a neuro bipolar EMG eb with: 1) Two dynamic recording channels and a frequency response of 20KHz during a 100 millisecond scan; 2) Integrated acoustic and visual stimulators; Figure 2: Neuro bipolar EMG eb. 3) Computer including all necessary software, hardware and accessories (Figure 2). The graphical recording of the anterior masseter and temporal muscles on both sides for each patient was obtained by means of self-adhesive electrodes fixed on the skin covering the muscles concerned, following the direction of the muscle fibers detected by palpation. The impedance at the passage of the current was reduced by a scrupulous cleaning of the cutaneous part used, with alcohol at 90 °. To obtain these recordings, each patient was asked to remove his orthodontic appliance and perform right and then left lateral movements (Figure 3). Figure 3: Self-adhesive electrodes. The same procedure was carried out for the recording of the electrical activity of the temporals and masseter during laterality movements, with the Planas apparatus installed. For all recordings, the patient was seated, with the Frankfurt plane almost parallel to the ground. In addition, efforts have been made to create an atmosphere of tranquility and silence. All recordings were made by the same neurologist. Results The computer provides a qualitative record of the frequency spectrum achieved by the patient’s muscles. The record obtained corresponds to the maximum power developed by the muscular system. In each patient who performs plate-free slippery laterality movements, a moderate increase in","PeriodicalId":196515,"journal":{"name":"Open Access Research in Anatomy","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134302346","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信