C. Lefort, É. Chouzenoux, L. Magnol, H. Massias, J. Pesquet
{"title":"Multi-parametric 3D-point-spread function estimation in deep multiphoton microscopy with an original computational strategy dedicated to the reconstruction of muscle images","authors":"C. Lefort, É. Chouzenoux, L. Magnol, H. Massias, J. Pesquet","doi":"10.1117/12.2554742","DOIUrl":"https://doi.org/10.1117/12.2554742","url":null,"abstract":"Three-dimensional (3D), in vivo and in live imaging of living samples with a sub-micrometer resolution is a current necessity for biomedical researches which corresponds to a hot topic for microscopy engineers. It is likely that the role of computational approaches is yet underestimated and underused in 3D-microscopy. This paper is an illustration of the fundamental role that could be played by such strategies. Usual imaging depths in biomedical microscopy reach few hundreds of micrometers in optimal conditions when multiphoton approaches are favored. However, light scattering and absorption still damage image quality, especially as imaging depth increases. Our approach rests on the multi-parametric 3D-PSF estimation of the true 3DGaussian model of the PSF along multi-millimeter depth. Image acquisition in MPM generates stacks of 2D images constituting an overall 3D-image. 3D-volumes of images containing a single object are selected and isolated all along the depth using automatic morphological tools. Finally, our computational 3DGaussian shape-fitting algorithm named FIGARO is applied on each individual PSF and quantify PSF full-width at half maximum (FWHM) in the 3 dimensions simultaneously with PSF tilt angles. FWHM evolution in the 3 dimensions along the 2 mm depth highlights a highly significant effect of spherical aberrations. Starting from standard values of PSF measured at sample top compared to what expected in MPM, we show an increase with a factor three of the PSF FWHM in axial plane when the sample bottom is reached, and no modification of PSF dimensions in lateral plane all along the depth. The main direction of the PSF shows a convergence toward a focal point that will be discussed","PeriodicalId":173282,"journal":{"name":"Optical Sensing and Detection VI","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114181371","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Performance of silver-plated silicon photodetector in near-infrared band","authors":"Yu-Chieh Huang, V. Parimi, Ching-Fuh Lin","doi":"10.1117/12.2555647","DOIUrl":"https://doi.org/10.1117/12.2555647","url":null,"abstract":"The accurate determination of the azimuth of a given direction, e.g., the true (geographic) North, is of fundamental importance in many fields. Just as few examples, it guides buildings construction in civil engineering, supports environmental and cartographic surveys, allows the correct positioning and stability control of concentrating solar power plants, as well as of airport installations, provides the geographic North reference for geomagnetic measurements, contributes to the interpretation of the orientation choices of ancient constructions in archeoastronomy, can be the primary benchmark to calibrate other compasses or gyroscopes. When aiming at reaching azimuth measurements with accuracies well below 1°, magnetic compasses are unreliable: firstly, they indicate the magnetic North rather than the geographic one; secondly, they are heavily influenced by possible surrounding ferromagnetic items.","PeriodicalId":173282,"journal":{"name":"Optical Sensing and Detection VI","volume":"78 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132399802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hengbin Zhang, Youcheng Tian, Jianghua Guo, Junku Liu, Lin Xiao, Jun Xie
{"title":"Origins of the wavelength dependent timing jitter in superconducting nanowire single photon detector","authors":"Hengbin Zhang, Youcheng Tian, Jianghua Guo, Junku Liu, Lin Xiao, Jun Xie","doi":"10.1117/12.2565528","DOIUrl":"https://doi.org/10.1117/12.2565528","url":null,"abstract":"A 2D hot spot diffusion model for describing the superconducting nanowire response to single photon is presented. We develop the 1D hot belt model to 2D hot spot model and can capture the initial stage of the hot spot evolution after photon absorption, this is helpful to comprehensive understand the origins and underlying physics of time jitter in superconducting nanowire-based single-photon detectors. Furthermore, the developed model can qualitatively explain the asymmetry and photon wavelength dependent probability density function (PDF) of the delay time. We find that the left and right half of the PDF distributions respective exhibit the Gauss and non-Gauss shape as increasing the excitation wavelength or decreasing the bias current, and the origins are discussed and analyzed in the framework of newly developed 2D model. The proposed 2D hot spot diffusion model will not only sheds light on the origin and influence of the timing jitter but will also reveal the work principle of the superconducting nanowire devices.","PeriodicalId":173282,"journal":{"name":"Optical Sensing and Detection VI","volume":"279 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131825503","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}