{"title":"Determining the Effectiveness of the Superensemble for Atmospheric Concentration Prediction","authors":"Frank Gronwald, Shoou-Yuh Chang","doi":"10.12691/jap-10-1-1","DOIUrl":"https://doi.org/10.12691/jap-10-1-1","url":null,"abstract":"","PeriodicalId":159328,"journal":{"name":"Journal of Atmospheric Pollution","volume":"11 9","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141921512","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
F. O. Anjorin, S. A. Abashi, F. Masok, I. M. Essen
{"title":"Comparative Assessment of Some Emitted Pollutants’ Concentrations from Selected Fossil Fuel-fired Generators","authors":"F. O. Anjorin, S. A. Abashi, F. Masok, I. M. Essen","doi":"10.12691/jap-8-1-1","DOIUrl":"https://doi.org/10.12691/jap-8-1-1","url":null,"abstract":"Fossil fuel-fired generators, though viable alternative sources of energy are a veritable source of several environmental problems. Measurements of gaseous and particle air pollutants is a vital step in exposure assessment and epidemiological studies. In this study, in-situ measurement of some pollutants emitted from selected fossil fuel-fired generators with a wide range of installed capacities (0.9-250kVA), which are under more realistic conditions than the laboratory approach of chamber testing was undertaking using real-time active sampling weekly for one year (November, 2015- October, 2016). The study reveals that the emission rate of CO from 0.9kVA generator, 2.0kVA generator, 50kVA CAT generator, 50kVA Micano generator, 250 kVA generator and 100kVA Micano generator are 93.48 mg/s, 107.67 mg/s, 1.12 mg/s, 12.47 mg/s, 0.08 mg/s and 9.69 mg/s, respectively; Similarly, the emission rate of SO2 from the aforementioned generators are 0.99 mg/s, 1.08 mg/s, 0.07 mg/s, 2.27 mg/s, 0.11 mg/s and 0.93 mg/s, respectively. Furthermore, these generators also emit H2S at the rate of 0.64 mg/s, 0.51 mg/s, 017 mg/s 1.79 mg/s, 0.15 mg/s and 0.92 mg/s, respectively. An insightful analysis of the sampled emission data suggests that emissions from most of the selected generators pose serious potential hazard to the public heath of their immediate neighbourhood.","PeriodicalId":159328,"journal":{"name":"Journal of Atmospheric Pollution","volume":"205 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2020-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116359899","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}