Reviews in Separation Sciences最新文献

筛选
英文 中文
Reporting Analytical Data for Regulatory Submissions: A CRO Perspective on Implementing the BP4NTA Study Reporting Tool in the Healthcare Industry 报告监管提交的分析数据:在医疗保健行业实施BP4NTA研究报告工具的CRO视角
Reviews in Separation Sciences Pub Date : 2022-11-13 DOI: 10.17145/rss.22.004
Nicole Dunn, Anna Michelson, Louis Fleck, G. Vas
{"title":"Reporting Analytical Data for Regulatory Submissions: A CRO Perspective on Implementing the BP4NTA Study Reporting Tool in the Healthcare Industry","authors":"Nicole Dunn, Anna Michelson, Louis Fleck, G. Vas","doi":"10.17145/rss.22.004","DOIUrl":"https://doi.org/10.17145/rss.22.004","url":null,"abstract":"Analytical data packages are an essential part of the CMC (Chemistry and Manufacturing Control) section of US FDA (United States Food and Drug Administration) NDA (new drug application) submissions for pharmaceuticals and biologics. In many cases, the biocompatibility assessment for medical devices also requires analytical testing to be performed and reported. Based on the quality of the data presented, the regulatory review team makes an informed decision about the safety of the drug product or the medical device. If the submission is incomplete or does not support the safety assessment of the product, additional data may be required, which often delays product approval. Study sponsors must decide between optimizing the amount and quality of the data in the filing packages to save costs upfront, which may delay the approval process versus taking the more conservative approach of providing detailed information, investing more upfront, and minimizing the risk of delays.","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124571295","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of Extraction Conditions for Volatile Extractables from Polypropylene, PBT Resins, and Chlorobutyl Rubber Elastomers Using a Variety of Solvents and Extraction Techniques 聚丙烯、PBT树脂和氯丁基橡胶弹性体中挥发性萃取物在不同溶剂和萃取技术下的萃取条件评价
Reviews in Separation Sciences Pub Date : 2022-11-05 DOI: 10.17145/rss.22.003
D. Norwood, L. Fleck, Emre Seyyal, Anna Michelson, G. Vas
{"title":"Evaluation of Extraction Conditions for Volatile Extractables from Polypropylene, PBT Resins, and Chlorobutyl Rubber Elastomers Using a Variety of Solvents and Extraction Techniques","authors":"D. Norwood, L. Fleck, Emre Seyyal, Anna Michelson, G. Vas","doi":"10.17145/rss.22.003","DOIUrl":"https://doi.org/10.17145/rss.22.003","url":null,"abstract":"Chemical safety assessment is one necessary step to demonstrate that the polymer used is free from harmful chemicals. The assessment should start with adequate material characterization using state-of-the-art analytical methods, including various chromatography techniques most often hyphenated with mass-spectrometric detection. Since polymers are usually incompatible with direct analysis using chromatography-based techniques, an extraction step is required prior to analytical testing. This paper provides information for practitioners who need to understand how to develop science-based extraction conditions that enable the determination of the polymer composition with respect to volatile compounds. Analytical data sets for three types of polymers (polypropylene, polycarbonate, polybutylene terephthalate, and a rubber elastomer) are presented using three different solvents and three different extraction techniques. The extracts were collected at different times during extraction and analyzed by GC-MS. The differences observed between extraction techniques, conditions, and solvents are discussed to better understand the impact of these parameters in extractable studies.","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129749366","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Impact of the GC-MS Injection Solvent and the Analyte Concentration on Relative Responses for common Extractables GC-MS进样溶剂和分析物浓度对常用萃取物相对响应的影响
Reviews in Separation Sciences Pub Date : 2022-03-22 DOI: 10.17145/rss.22.002
D. Norwood, Anna Michelson, Nicole Dunn, J. Duett, Louis Fleck, G. Vas
{"title":"Impact of the GC-MS Injection Solvent and the Analyte Concentration on Relative Responses for common Extractables","authors":"D. Norwood, Anna Michelson, Nicole Dunn, J. Duett, Louis Fleck, G. Vas","doi":"10.17145/rss.22.002","DOIUrl":"https://doi.org/10.17145/rss.22.002","url":null,"abstract":"Sample introduction in the GC-MS analysis is a relatively complex, multistep process, where usually a liquid sample is introduced to an injector, evaporated, and transferred to the GC column. To achieve reliable quantitation, the process must be well controlled. In the past decade or so, GC-MS based relative responses were evaluated for hundreds of extractables with the benefit of using those relative response factors for quantitation or to create databases to somewhat bridge the existing gap to estimate the amount of non-identified analytes. No data has yet been published indicating how relative responses are impacted by different injection solvents, or when the evaluation level is addressing the sub µg/mL levels. This paper presents data sets for 74 impurities (0.5-5 µg/mL range), with multiple internal standards, using 8 injection vehicles. Based on the presented data, the injection vehicle has a significant impact on the relative response factors, and therefore the quantitative assignment of the impurities.","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133250009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Multiple Headspace Extraction-Selected Ion Flow Tube Mass Spectrometry (MHE-SIFT-MS). Part 1: A Protocol for Method Development and Transfer to Routine Analysis 多重顶空萃取-选择离子流管质谱(MHE-SIFT-MS)。第1部分:方法开发和转移到常规分析的协议
Reviews in Separation Sciences Pub Date : 2022-01-23 DOI: 10.17145/rss.22.001
M. Perkins, V. Langford
{"title":"Multiple Headspace Extraction-Selected Ion Flow Tube Mass Spectrometry (MHE-SIFT-MS). Part 1: A Protocol for Method Development and Transfer to Routine Analysis","authors":"M. Perkins, V. Langford","doi":"10.17145/rss.22.001","DOIUrl":"https://doi.org/10.17145/rss.22.001","url":null,"abstract":"The toxicity of many volatile organic compounds (VOCs) means that the safety of polymeric and other materials in contact with, or near, pharmaceutical and food products must be assured through sensitive, quantitative measurement. The multiple headspace extraction (MHE) technique was developed in the 1980s to provide quantitative analysis of VOCs in condensed-phase samples. Selected ion flow tube mass spectrometry (SIFT-MS) is a direct-injection mass spectrometry (DIMS) technique that often significantly reduces the analysis time for routine VOCs in headspace compared to gas chromatography (GC) methods. Using the prototypical polystyrene system, this study represents the first detailed application of MHE to SIFT-MS, describing protocols for method development (including optimization of equilibration temperature and time, plus calibration), data evaluation, and adoption of the technique into routine analysis. MHE-SIFT-MS gives an eight-fold throughput advantage over MHE-GC while being highly repeatable (relative standard deviation, RSD, less than 2%).","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124354023","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Evaluation of Vitamin E Acetate Volatile Degradation Products; a possible Connection to the EVALI Epidemic 维生素E醋酸酯挥发性降解产物的评价可能与EVALI流行病有关
Reviews in Separation Sciences Pub Date : 2021-10-25 DOI: 10.17145/rss.21.004
G. Vas
{"title":"Evaluation of Vitamin E Acetate Volatile Degradation Products; a possible Connection to the EVALI Epidemic","authors":"G. Vas","doi":"10.17145/rss.21.004","DOIUrl":"https://doi.org/10.17145/rss.21.004","url":null,"abstract":"","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132479294","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Biofluid Collection in Metabolomics by the Application of the novel Volumetric Absorptive Microsampling Technology: a mini-Review 应用新型体积吸收微采样技术收集代谢组学中的生物流体:综述
Reviews in Separation Sciences Pub Date : 2019-10-15 DOI: 10.17145/rss.19.004
R. Meesters
{"title":"Biofluid Collection in Metabolomics by the Application of the novel Volumetric Absorptive Microsampling Technology: a mini-Review","authors":"R. Meesters","doi":"10.17145/rss.19.004","DOIUrl":"https://doi.org/10.17145/rss.19.004","url":null,"abstract":"Volumetric absorptive microsampling (VAMS) is a novel microsampling technology that is frequently used for the collection of biofluids for the application in a plethora of bioanalytical applications and assays. Recently, few papers have reported the successful application of VAMS in untargeted as well in targeted metabolomics. VAMS in metabolomics can become in the near future a very promising microsampling technique, but to that moment, some application-related aspects of VAMS in the metabolomics workflow still needs some in depth investigation and evaluation. In this mini-review article, the application of VAMS in metabolomics, procedures applied and first results obtained are described, evaluated and discussed.","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"205 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116190845","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Hybrid Ligand Binding Immunoaffinity-Liquid Chromatography/Mass Spectrometry for Biotherapeutics and Biomarker Quantitation: How to develop a hybrid LBA-LC-MS/MS method for a protein? 混合配体结合免疫亲和-液相色谱/质谱法用于生物治疗和生物标志物定量:如何开发一种混合LBA-LC-MS/MS方法用于蛋白质?
Reviews in Separation Sciences Pub Date : 2019-10-15 DOI: 10.17145/rss.19.005
Y Moucun, Oaj Ismaiel, WR Mylott
{"title":"Hybrid Ligand Binding Immunoaffinity-Liquid Chromatography/Mass Spectrometry for Biotherapeutics and Biomarker Quantitation: How to develop a hybrid LBA-LC-MS/MS method for a protein?","authors":"Y Moucun, Oaj Ismaiel, WR Mylott","doi":"10.17145/rss.19.005","DOIUrl":"https://doi.org/10.17145/rss.19.005","url":null,"abstract":"Bioanalysis of protein-based therapeutics have historically used ligand binding immunoaffinity (LBA) approaches. However, recently LBA has been combined with Liquid Chromatography-Mass Spectrometry, resulting in the term hybrid (LBA)LC-MS/MS techniques. Hybrid LC-MS/MS has successfully been applied to the bioanalysis of biotherapeutics and biomarkers. The basic concept of hybrid LC-MS/MS can be defined as combining LBA for the selective isolation/enrichment of the target analyte from the biomatrix and LC-MS for selective detection of the isolated analyte. In this article, we present a brief overview of How To develop a hybrid LBA-LC-MS/MS method for biotherapeutics and biomarkers with an emphasis on the general workflow and procedures.","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"48 14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121717707","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Advances in the Optimization of Chromatographic Conditions for the Separation of Antioxidants in Functional Foods 功能食品中抗氧化剂分离色谱条件优化研究进展
Reviews in Separation Sciences Pub Date : 2019-10-15 DOI: 10.17145/rss.19.003
N. Kalogiouri, V. Samanidou
{"title":"Advances in the Optimization of Chromatographic Conditions for the Separation of Antioxidants in Functional Foods","authors":"N. Kalogiouri, V. Samanidou","doi":"10.17145/rss.19.003","DOIUrl":"https://doi.org/10.17145/rss.19.003","url":null,"abstract":"Antioxidants represent a class of naturally occurring molecules that are responsible for several health properties. Antioxidants are present in various natural products and food matrices, typically known as “functional foods”. Because of their high nutritional value and antioxidant activity, functional foods gain considerable attention, in recent years. Phenolic compounds are the most abundant class of antioxidants and Liquid Chromatography (LC) is the main technique used for their separation. Conventional High-Pressure Liquid Chromatography provides insufficient resolving power and requires long analysis times. New techniques like ultra-high-pressure liquid chromatography (UHPLC), in reversed-phase (RP) or hydrophilic interaction (HILIC) mode, and the development of multidimensional methods prove promising with increasing applications for phenolic analysis. The aim of this review is to provide an updated overview of the applications of recent advances in LC phenolic separation of antioxidants in functional within the period 2015-2019.","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116686783","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Welcome to Reviews in Separation Sciences 欢迎来到《分离科学评论》
Reviews in Separation Sciences Pub Date : 2019-10-15 DOI: 10.17145/rss.19.001
O. Ismaiel
{"title":"Welcome to Reviews in Separation Sciences","authors":"O. Ismaiel","doi":"10.17145/rss.19.001","DOIUrl":"https://doi.org/10.17145/rss.19.001","url":null,"abstract":"©2019 Ismaiel OA. This is an open access article distributed under the terms of the Creative Commons Attribution License (CC-BY) which permits any use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. PPD Laboratories, Richmond, VA 23230, United States. Department of Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt. Correspondence: editor.rss@betasciencepress.com First draft submitted: July 12, 2019; Accepted for publication: July 23, 2019. Reviews in Separation Sciences","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134113643","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development and Validation of a Stability-Indicating Method for Bone Morphogenetic Protein-2 骨形态发生蛋白-2稳定性指示方法的建立与验证
Reviews in Separation Sciences Pub Date : 2019-10-15 DOI: 10.17145/rss.19.002
Deblina Biswas, Laure Ray, M. Halquist
{"title":"Development and Validation of a Stability-Indicating Method for Bone Morphogenetic Protein-2","authors":"Deblina Biswas, Laure Ray, M. Halquist","doi":"10.17145/rss.19.002","DOIUrl":"https://doi.org/10.17145/rss.19.002","url":null,"abstract":"Complex parenteral dosage forms such as subcutaneous implants and liposomes are often associated with diffusion or erosion-based release mechanism of the drug product. One such formulation is INFUSE® Bone Graft. It involves release of a recombinant human bone morphogenetic protein (rhBMP-2) from a biodegradable absorbable collagen sponge (ACS) scaffold. In order to characterize the release of rhBMP-2 from ACS or other scaffolds in a biorelevant media, a simple, precise and accurate stability-indicating high-performance liquid chromatography (HPLC) method was developed and validated. The total run time of the method was 9 min, and the rhBMP-2 retention time was 3.44 min. The dynamic range of the assay was determined to be 0.50–100μμg/mL. The limit of detection (LOD and quantification (LOQ) were observed to be 0.18μμg/mL and 0.50μμg/mL, respectively. Reverse predicted residuals, inter-day accuracy and inter-day precision were all less than 10% including at the LOQ. Forced degradation studies revealed no chromatographic interference from excipients, media or degradant peaks. Mass spectrometric detection was used for further characterization of rhBMP-2 glycoforms in the formulation. Oxidation and deamidation were predicted as the most common degradation mechanism for the protein. The developed method was applied for studying release-testing samples from a novel biorelevant in vitro drug release model (BIVDR). In conclusion, the HPLCbased assay method can be used for studying rhBMP-2 concentrations released from an ACS scaffold in dissolution media.","PeriodicalId":126178,"journal":{"name":"Reviews in Separation Sciences","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121882849","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书