NUMERICAL SIMULATION OF STRAIN WITHIN THE CONSTRUCTIONS FOR TEMPORARY HEMIEPIPHYSEODESIS IN PATIENTS WITH SYSTEMIC SKELETAL DYSPLASIAS 全身性骨骼发育不良患者暂时性半骨骺成形症结构内应变的数值模拟
Vestnik travmatologii i ortopedii imeni N.N. Priorova Pub Date : 2018-03-15 DOI: 10.32414/0869-8678-2018-1-30-35
V. Kenis, Ekatrina Morenko, A. Korshunov, R. Kleimanov
{"title":"NUMERICAL SIMULATION OF STRAIN WITHIN THE CONSTRUCTIONS FOR TEMPORARY HEMIEPIPHYSEODESIS IN PATIENTS WITH SYSTEMIC SKELETAL DYSPLASIAS","authors":"V. Kenis, Ekatrina Morenko, A. Korshunov, R. Kleimanov","doi":"10.32414/0869-8678-2018-1-30-35","DOIUrl":"https://doi.org/10.32414/0869-8678-2018-1-30-35","url":null,"abstract":"Introduction. Guided growth (temporary hemiepiphyseodesis) methods for the correction of axial deformities at the knee joint level in children are used mainly in patients with idiopathic deformities. In patients with systemic skeletal dysplasias the use of these techniques does not take into account the peculiarities of the pathological process. Purpose of study: to evaluate with radiographs the incidence of incomplete plate-bone contact at temporary hemiepiphyseodesis; to assess tensely deforming condition of metal implants using numerical simulation of strain in patients with systemic skeletal dysplasias for the prognosis of their potential failure.Patients and methods. Postoperative radiographs were analyzed for 58 children with systemic skeletal dysplasias after temporary hemiepiphyseodesis (107 extremities, 188 plates; main group) and 50 patients with the deformities of other etiology (control group). Plate-metaphysis contact was considered to be incomplete if it exceeded 2 mm. To determine the plate strains and displacement during the process of bone growth the numerical simulation using COSMOL Multiphusics Software was performed.Results. Incomplete plate-bone contact was observed in 41 (22%) out of 188 constructions. Mean contact deficit made up 4.1±1.3 mm. In control group incomplete plate- bone contact (over 2 mm) was observed only in 3 (4.5%) cases (p<0.05). When a screw is not completely inserted into the bone, its’ the most loaded part is out of the bone and the risk of screw breakage in the contact zone occurs. That was showed by the data of numerical strain simulation.Conclusion. In temporary hemiepiphyseodesis the potentiality of incomplete plate-bone contact resulting from the anatomical peculiarities of epimetaphyseal zone is up to 22%. To improve the efficacy of the guided growth method in children with systemic skeletal dysplasias the elaboration of the constructions should take into account of epimetaphyseal zone configuration.","PeriodicalId":117287,"journal":{"name":"Vestnik travmatologii i ortopedii imeni N.N. Priorova","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126646477","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信