Chromatography最新文献

筛选
英文 中文
Development of Cryogenic HPLC for Wide Range Low Temperatures Using Liquefied Propane as Mobile Phase and Its Application to Hydrogen/Deuterium Compounds Separation 以液化丙烷为流动相的宽范围低温高效液相色谱的开发及其在氢/氘化合物分离中的应用
IF 1.7
Chromatography Pub Date : 2023-12-31 DOI: 10.15583/jpchrom.2023.018
Masahiro Hattori, Hiroki Iwase, S. Kitagawa, Yoshinori Iiguni, Hajime Ohtani
{"title":"Development of Cryogenic HPLC for Wide Range Low Temperatures Using Liquefied Propane as Mobile Phase and Its Application to Hydrogen/Deuterium Compounds Separation","authors":"Masahiro Hattori, Hiroki Iwase, S. Kitagawa, Yoshinori Iiguni, Hajime Ohtani","doi":"10.15583/jpchrom.2023.018","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.018","url":null,"abstract":"","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"117 27","pages":""},"PeriodicalIF":1.7,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139134028","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Capillary Electrophoretic Characterization of Platinum and Silver Nanoparticles in Aqueous Solution Prepared by a Solution Plasma Process 利用溶液等离子工艺制备水溶液中的铂和银纳米粒子的毛细管电泳特性分析
IF 1.7
Chromatography Pub Date : 2023-12-13 DOI: 10.15583/jpchrom.2023.022
Toshio Takayanagi, Taiki Hirose, Hitoshi Mizuguchi, Hirotaka Okabe, Naoki Matsuda
{"title":"Capillary Electrophoretic Characterization of Platinum and Silver Nanoparticles in Aqueous Solution Prepared by a Solution Plasma Process","authors":"Toshio Takayanagi, Taiki Hirose, Hitoshi Mizuguchi, Hirotaka Okabe, Naoki Matsuda","doi":"10.15583/jpchrom.2023.022","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.022","url":null,"abstract":"","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"177 S427","pages":""},"PeriodicalIF":1.7,"publicationDate":"2023-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139006144","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Amino Acid Analysis in Rat Wound Exudate by High-Performance Liquid Chromatography-Fluorescence Detection 用高效液相色谱-荧光检测法分析大鼠伤口渗出液中的氨基酸
IF 1.7
Chromatography Pub Date : 2023-12-04 DOI: 10.15583/jpchrom.2023.021
Makoto Tsunoda, Yuma Ishida, Mao Kunimitsu
{"title":"Amino Acid Analysis in Rat Wound Exudate by High-Performance Liquid Chromatography-Fluorescence Detection","authors":"Makoto Tsunoda, Yuma Ishida, Mao Kunimitsu","doi":"10.15583/jpchrom.2023.021","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.021","url":null,"abstract":"","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"19 20","pages":""},"PeriodicalIF":1.7,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138604174","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Liquid Chromatography Based Multiplex Gene Expression Analysis Using Fluorous Separation Technique with Fluorescence Detection 基于荧光检测荧光分离技术的液相色谱多重基因表达分析
Chromatography Pub Date : 2023-10-20 DOI: 10.15583/jpchrom.2023.020
Kenichiro TODOROKI, Chiemi MIYAUCHI, Tatsunosuke TOMITA, Jun Zhe MIN, Koichi INOUE, Toshimasa TOYO'OKA
{"title":"Liquid Chromatography Based Multiplex Gene Expression Analysis Using Fluorous Separation Technique with Fluorescence Detection","authors":"Kenichiro TODOROKI, Chiemi MIYAUCHI, Tatsunosuke TOMITA, Jun Zhe MIN, Koichi INOUE, Toshimasa TOYO'OKA","doi":"10.15583/jpchrom.2023.020","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.020","url":null,"abstract":"We have developed a comprehensive method for analyzing gene expression levels by combining the fluorous-fluorescence hybrid probes, oligonucleic acids modified with a perfluoroalkyl tag and fluorescent probes, with the fluorous liquid chromatography (LC) – fluorescence detection. When Taq polymerase chain reaction (PCR) was performed using this probe, fluorescent mononucleotides were released according to the amount of template gene targeted. Because each probe differs in the linker length of the fluorescent probe and the type of nucleobase, multiple gene expression levels can be analyzed by LC as the amount of fluorescent mononucleotides produced. The excess unreacted probe, which did not undergo the Taq PCR reaction, was selectively removed by adsorption in the fluorous LC column introduced as a pretreatment column. The method established in this study allows simultaneous LC quantification of three housekeeping genes. In addition, LC separation conditions for the simultaneous analysis of nine gene expression levels were established, and comprehensive detection of cytokine genes in lipopolysaccharide-stimulated leukocytes was successfully achieved.","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135513814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Elution Behavior of Carbohydrates Using Core-Shell Ion-Exchange Resin St-70 with Different Degrees of Cross-Linking in the Porous Shell 多孔壳中不同交联度核壳离子交换树脂St-70对碳水化合物的洗脱行为
Chromatography Pub Date : 2023-10-20 DOI: 10.15583/jpchrom.2023.008
Shun-ichi MITOMO, Yutaka INOUE, Takashi TANIKAWA, Yukiko NEGISHI
{"title":"Elution Behavior of Carbohydrates Using Core-Shell Ion-Exchange Resin St-70 with Different Degrees of Cross-Linking in the Porous Shell","authors":"Shun-ichi MITOMO, Yutaka INOUE, Takashi TANIKAWA, Yukiko NEGISHI","doi":"10.15583/jpchrom.2023.008","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.008","url":null,"abstract":"A novel core-shell ion-exchange resin (St-70) having a core-shell monomer weight ratio of 30:70 was prepared for use in highperformance liquid chromatography (HPLC), and the effect of the degree of cross-linking (10–55%) of the porous shell on the separation of carbohydrates was examined. A mixture of inositol, glucose, fructose, and sucrose was separated under alkaline conditions (100 and 150 mmol/L NaOH) at flow rates of 0.3–0.7 mL/min using St-70, which exhibited a degree of cross-linking of 10, 40, and 55%. The retention time of carbohydrates decreased with increasing of the degree of cross-linking in the porous shell. The theoretical plate number (N) of glucose, fructose, and sucrose decreased with decreasing the degree of cross-linking when 100 mmol/L NaOH eluent was used at flow rates of 0.3 and 0.5 mL/min.","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"77 5","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135513815","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Foam-Eliminatory Purge-and-Trap Technique Using a Functional PTFE Membrane and Needle-Type Extraction Device to Determine Flavors in Drink Samples 利用功能性聚四氟乙烯膜和针式萃取装置测定饮料样品中的风味的泡沫消除清洗和捕集技术
Chromatography Pub Date : 2023-10-20 DOI: 10.15583/jpchrom.2023.014
Ikuo UETA, Hiroto MAKABE, Suguru MASUDA, Koki NAKAGAMI, Yoshihiro SAITO
{"title":"Foam-Eliminatory Purge-and-Trap Technique Using a Functional PTFE Membrane and Needle-Type Extraction Device to Determine Flavors in Drink Samples","authors":"Ikuo UETA, Hiroto MAKABE, Suguru MASUDA, Koki NAKAGAMI, Yoshihiro SAITO","doi":"10.15583/jpchrom.2023.014","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.014","url":null,"abstract":"A simple and sensitive method for determining flavor compounds in foamable liquid samples was developed using the purge-and-trap method with the addition of glass wool and a functional porous polytetrafluoroethylene (PTFE) membrane. Flavor compounds purged from sample solutions were trapped by a needle-type extraction device. The functional PTFE membrane, which retained the aqueous sample while allowing purge gas to pass, was fixed on a glass solid-phase extraction cartridge. Hence, purge gas was continuously introduced into the sample solution from the bottom of the cartridge. To trap the foam, 0.4 g of glass wool was fixed in the sample headspace, and headspace gas was collected using a needle-type extraction device placed on the upper side of the wool. During the purge process, although foam climbed through the cartridge, it was adsorbed on the glass wool. However, the flavor compounds were not adsorbed on the inactive glass wool surface as confirmed in this study. This method does not require the dilution of sample solutions or the adding of antifoam agents to sample solutions. This simple and inexpensive construction enables the sensitive detection of flavor compounds.","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"21 2","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135513646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Determination of Volatile Polycyclic Aromatic Hydrocarbons in Soil Using Needle-Type Extraction 针式萃取法测定土壤中挥发性多环芳烃
Chromatography Pub Date : 2023-10-20 DOI: 10.15583/jpchrom.2023.017
Ikuo UETA, Syuhei KAMEI, Koki NAKAGAMI, Yoshihiro SAITO
{"title":"Determination of Volatile Polycyclic Aromatic Hydrocarbons in Soil Using Needle-Type Extraction","authors":"Ikuo UETA, Syuhei KAMEI, Koki NAKAGAMI, Yoshihiro SAITO","doi":"10.15583/jpchrom.2023.017","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.017","url":null,"abstract":"A new analytical method for the quantification of volatile polycyclic aromatic hydrocarbons (PAHs) in soil samples using a needle-type extraction device was developed. Naphthalene (Nap), acenaphthylene (Acy), acenaphthene (Ace), and fluorene (Flu) were investigated as analytes. Samples were prepared by placing 10 g of soil in a glass cartridge and immersing the cartridge in a 75°C water bath. The needle-type extraction device packed with Carbopack X and carbon molecular sieve was inserted into the glass cartridge, and 300 mL of gaseous sample was collected. During gas sampling, N2 was introduced into the cartridge through the tip of the cartridge. After collecting the sample, the extraction needle was inserted into a heated gas chromatographic (GC) injection port, and the extracted PAHs were thermally desorbed followed by the GC separation on a fused-silica capillary column. The limits of quantification for Nap, Acy, Ace, and Flu were 36, 36, 15, and 36 ng through flame ionization detector and 3.6, 7.5, 7.5, and 36 ng through mass spectrometry, respectively.","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135513655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of HPLC Optical Purity Testing Method of Denomapine and Application to Its Photostability 迪诺平HPLC光学纯度检测方法的建立及其光稳定性研究
Chromatography Pub Date : 2023-10-20 DOI: 10.15583/jpchrom.2023.016
Kohei KAWABATA, Mai SANDANBATA, Hiroyuki NISHI
{"title":"Development of HPLC Optical Purity Testing Method of Denomapine and Application to Its Photostability","authors":"Kohei KAWABATA, Mai SANDANBATA, Hiroyuki NISHI","doi":"10.15583/jpchrom.2023.016","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.016","url":null,"abstract":"Direct enantiomer separation of denopamine (DP, active form: R (-)-form), which is an optically active and an orally administrable cardiotonic agent, was investigated by HPLC with β-cyclodextrin (β-CD) immobilized chiral stationary phases (CSPs). Successful enantiomer separation under the reversed-phase mode was achieved by a β-CD having a phenyl moiety immobilized CSP with large resolution within 10 min. Optical purity testing and assay of tablets by the HPLC method developed were validated for specificity, linearity, and recovery. Validation results indicate the method is accurate and has a good linearity and sensitivity. Limit of detection and limit of quantitation of the minor enantiomer were 0.01% and 0.03%, respectively. Assay of DP tablets 5 mg by the internal standard method was also successfully achieved within 10 min. Further, photostability of DP was evaluated by this chiral HPLC method and the reversed-phase HPLC with an ODS column. Chemical structures of two photoproducts generated in an aqueous media were determined by LC-MS/MS, showing these were p-hydroxybenzaldehyde and 3,4-dimethoxyphenethylamine. Other than these two main photoproducts, low level (0.17%) of the minor enantiomer was detected.","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"79 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135513421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
LVSEP Analysis of Cationic Analytes in Non-Aqueous Media on Cationic Polymer-Coated Channel Microchips 非水介质中阳离子分析物在阳离子聚合物涂层通道微芯片上的LVSEP分析
Chromatography Pub Date : 2023-10-20 DOI: 10.15583/jpchrom.2023.019
Fumihiko KITAGAWA, Yurie TAKAHASHI, Isoshi NUKATSUKA
{"title":"LVSEP Analysis of Cationic Analytes in Non-Aqueous Media on Cationic Polymer-Coated Channel Microchips","authors":"Fumihiko KITAGAWA, Yurie TAKAHASHI, Isoshi NUKATSUKA","doi":"10.15583/jpchrom.2023.019","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.019","url":null,"abstract":"To improve the concentration sensitivity of cationic analytes in microchip electrophoresis, on-line sample preconcentration by a large-volume sample stacking with an electroosmotic flow pump (LVSEP) was performed using non-aqueous background solutions (BGSs) in cationic polymer-coated microchannels. In the LVSEP analyses using dimethyl sulfoxide-based BGS, however, poly(vinyl alcohol)/poly(allylamine) mixture-coated microchannel gave insufficient enrichments and broader peaks for cationic histamine. By employing a methanolic BGS containing (hydroxypropyl)methyl cellulose, on the other hand, good enrichments of histamine were achieved by LVSEP with the sensitive enhancement factor of 67. To our knowledge, this is first time that LVSEP analyses of cationic analytes were successfully realized in non-aqueous media.","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"12 3","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135513971","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Enantioselective Analysis of Lactate, Hydroxybutyrates and Malate in Human Physiological Fluids Using a Three-Dimensional HPLC System 三维高效液相色谱系统对人体生理液体中乳酸、羟丁酸和苹果酸盐的对映选择性分析
Chromatography Pub Date : 2023-10-20 DOI: 10.15583/jpchrom.2023.015
Hsin-Miao TSAI, Chin-Ling HSIEH, Chiharu ISHII, Takeyuki AKITA, Masashi MITA, Tomomi IDE, Jen-Ai LEE, Kenji HAMASE
{"title":"Enantioselective Analysis of Lactate, Hydroxybutyrates and Malate in Human Physiological Fluids Using a Three-Dimensional HPLC System","authors":"Hsin-Miao TSAI, Chin-Ling HSIEH, Chiharu ISHII, Takeyuki AKITA, Masashi MITA, Tomomi IDE, Jen-Ai LEE, Kenji HAMASE","doi":"10.15583/jpchrom.2023.015","DOIUrl":"https://doi.org/10.15583/jpchrom.2023.015","url":null,"abstract":"For the highly-selective analysis of lactic acid (LA), 2-hydroxybutyric acid (2HB), 3-hydroxybutyric acid (3HB) and malic acid (MA) enantiomers in human physiological fluids, a three-dimensional (3D) HPLC method following the fluorescence derivatization with 4-nitro-7-piperazino-2,1,3-benzoxadiazole has been designed and developed. The 3D-HPLC system was composed of reversed-phase, mixed-mode and enantioselective columns, and the conditions of all the dimensions were thoroughly investigated. In the first and second dimensions, the target hydroxy acids were separated from most of the interfering substances in the clinical samples. In the third dimension, the enantiomers were separated with resolution values higher than 3.47. The present method was validated by checking the calibration curves, precision and accuracy using standard solutions and human samples, and satisfactory results were acquired. Using the 3D-HPLC system, D-LA, L-LA, D-3HB, L-3HB and L-2HB were determined in the human plasma and urine (maleic acid enantiomers were not determined). The concentrations of the detected enantiomers in the human plasma were 6.2, 660, 34.0, 1.0 and 19.0 µM, and those in the human urine were 13.4, 88.3, 4.5, 3.7 and 4.5 µM, respectively.","PeriodicalId":10272,"journal":{"name":"Chromatography","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135514275","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信