{"title":"使用法向入射光学测量系统进行线轮廓和关键尺寸测量","authors":"Weidong Yang, R. Lowe-Webb, R. Korlahalli, V. Zhuang, H. Sasano, Wei Liu, D. Mui","doi":"10.1109/ASMC.2002.1001586","DOIUrl":null,"url":null,"abstract":"Optical critical dimension metrology (OCD), an optical-wavelength light-diffraction technique, is currently undergoing an industry-wide evaluation as a fast, accurate, and non-destructive sub-100 nm line-width monitor. The spectroscopic, zeroth-order diffraction signature obtained from a printed diffraction grating allows extraction of structural information, such as linewidth, sidewall angle, and profile characteristics. The OCD spectrometer is compact and designed for integration into etch tools and lithography tracks. Effective process monitoring requires detailed understanding of the correlation between CD-SEM and OCD measurements. Correlation between the OCD technique and CD-SEM is investigated in this paper by measuring photo-resist gratings on a polysilicon gate film stack. The scatter in the correlation plot is shown to reduce significantly when several CD-SEM measurements are averaged from a single grating. A positive offset in the correlation is observed and a mechanism is proposed to account for the discrepancy.","PeriodicalId":64779,"journal":{"name":"半导体技术","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Line-profile and critical dimension measurements using a normal incidence optical metrology system\",\"authors\":\"Weidong Yang, R. Lowe-Webb, R. Korlahalli, V. Zhuang, H. Sasano, Wei Liu, D. Mui\",\"doi\":\"10.1109/ASMC.2002.1001586\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optical critical dimension metrology (OCD), an optical-wavelength light-diffraction technique, is currently undergoing an industry-wide evaluation as a fast, accurate, and non-destructive sub-100 nm line-width monitor. The spectroscopic, zeroth-order diffraction signature obtained from a printed diffraction grating allows extraction of structural information, such as linewidth, sidewall angle, and profile characteristics. The OCD spectrometer is compact and designed for integration into etch tools and lithography tracks. Effective process monitoring requires detailed understanding of the correlation between CD-SEM and OCD measurements. Correlation between the OCD technique and CD-SEM is investigated in this paper by measuring photo-resist gratings on a polysilicon gate film stack. The scatter in the correlation plot is shown to reduce significantly when several CD-SEM measurements are averaged from a single grating. A positive offset in the correlation is observed and a mechanism is proposed to account for the discrepancy.\",\"PeriodicalId\":64779,\"journal\":{\"name\":\"半导体技术\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"半导体技术\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.1109/ASMC.2002.1001586\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"半导体技术","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1109/ASMC.2002.1001586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

光学临界尺寸测量技术(OCD)是一种波长光衍射技术,作为一种快速、准确、无损的100纳米线宽监测技术,目前正在进行全行业的评估。从印刷衍射光栅获得的光谱,零级衍射特征允许提取结构信息,如线宽,侧壁角和轮廓特征。OCD光谱仪结构紧凑,可集成到蚀刻工具和光刻轨道中。有效的过程监控需要详细了解CD-SEM和OCD测量之间的相关性。本文通过测量多晶硅栅极膜堆上的光阻光栅,研究了OCD技术与CD-SEM之间的相关性。当从单个光栅取几个CD-SEM测量值的平均值时,相关图中的散点显着减少。观察到相关性中的正偏移,并提出了一种机制来解释这种差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Line-profile and critical dimension measurements using a normal incidence optical metrology system
Optical critical dimension metrology (OCD), an optical-wavelength light-diffraction technique, is currently undergoing an industry-wide evaluation as a fast, accurate, and non-destructive sub-100 nm line-width monitor. The spectroscopic, zeroth-order diffraction signature obtained from a printed diffraction grating allows extraction of structural information, such as linewidth, sidewall angle, and profile characteristics. The OCD spectrometer is compact and designed for integration into etch tools and lithography tracks. Effective process monitoring requires detailed understanding of the correlation between CD-SEM and OCD measurements. Correlation between the OCD technique and CD-SEM is investigated in this paper by measuring photo-resist gratings on a polysilicon gate film stack. The scatter in the correlation plot is shown to reduce significantly when several CD-SEM measurements are averaged from a single grating. A positive offset in the correlation is observed and a mechanism is proposed to account for the discrepancy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
8436
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信