基于矩阵电导法的湍流流体动力学研究中时空离散速度剖面重构相关测量方法的应用

IF 0.2 Q4 INSTRUMENTS & INSTRUMENTATION
S. Dmitriev, A. Khrobostov, D. N. Solncev, A. Barinov, A. Chesnokov, I. Konovalov, M. Makarov, T. K. Zyryanova
{"title":"基于矩阵电导法的湍流流体动力学研究中时空离散速度剖面重构相关测量方法的应用","authors":"S. Dmitriev, A. Khrobostov, D. N. Solncev, A. Barinov, A. Chesnokov, I. Konovalov, M. Makarov, T. K. Zyryanova","doi":"10.21122/2220-9506-2021-12-4-292-300","DOIUrl":null,"url":null,"abstract":"The correlation method for measuring of the coolant fl rate is used in the operation of nuclear power plants and is widespread in research practice including study of turbulent fl    hydrodynamics. However the question of its applicability and possibilities in studies using the matrix conductometry method remains open. Earlier the algorithm for determining of the correlation fl rate using a conductometric measuring system was highlighted and the error of the results obtained was estimated and the dependence of the influence of noise and the time of data collection on the reliability of results was investigated. These works were carried out using two independent mesh sensors and the issue of the resolution of local velocity components was not covered. The purpose of this work was to test the correlation method for measuring velocity with temporal and spatial sampling using two-layer mesh conductometric sensors.As the result velocity cartograms were obtained over the cross-section of the experimental model with quasi-stationary mixing and the value of the average flow rate is in good agreement with the values obtained from the standard flow meters of the stand. Also measurements were carried out at a non-stationary setting of the experiment and realizations of the flow rate and velocity components of the flow at the measuring points were obtained.Analysis of the obtained values allows to conclude about the optimal data collection time for correlation measurements, as well as the reliability of results.","PeriodicalId":41798,"journal":{"name":"Devices and Methods of Measurements","volume":"47 1","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2021-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of the Correlation Measurement Method for Reconstructing of the Velocity Profile with Spatial and Temporal Discretization in Studies of the Hydrodynamics of Turbulent Flows Based on the Matrix Conductometry Method\",\"authors\":\"S. Dmitriev, A. Khrobostov, D. N. Solncev, A. Barinov, A. Chesnokov, I. Konovalov, M. Makarov, T. K. Zyryanova\",\"doi\":\"10.21122/2220-9506-2021-12-4-292-300\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The correlation method for measuring of the coolant fl rate is used in the operation of nuclear power plants and is widespread in research practice including study of turbulent fl    hydrodynamics. However the question of its applicability and possibilities in studies using the matrix conductometry method remains open. Earlier the algorithm for determining of the correlation fl rate using a conductometric measuring system was highlighted and the error of the results obtained was estimated and the dependence of the influence of noise and the time of data collection on the reliability of results was investigated. These works were carried out using two independent mesh sensors and the issue of the resolution of local velocity components was not covered. The purpose of this work was to test the correlation method for measuring velocity with temporal and spatial sampling using two-layer mesh conductometric sensors.As the result velocity cartograms were obtained over the cross-section of the experimental model with quasi-stationary mixing and the value of the average flow rate is in good agreement with the values obtained from the standard flow meters of the stand. Also measurements were carried out at a non-stationary setting of the experiment and realizations of the flow rate and velocity components of the flow at the measuring points were obtained.Analysis of the obtained values allows to conclude about the optimal data collection time for correlation measurements, as well as the reliability of results.\",\"PeriodicalId\":41798,\"journal\":{\"name\":\"Devices and Methods of Measurements\",\"volume\":\"47 1\",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2021-12-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Devices and Methods of Measurements\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21122/2220-9506-2021-12-4-292-300\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Devices and Methods of Measurements","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21122/2220-9506-2021-12-4-292-300","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

相关法测量冷却剂流液率是核电站运行中常用的一种方法,在包括湍流流液动力学研究在内的研究实践中得到了广泛的应用。然而,它在使用矩阵电导法研究中的适用性和可能性问题仍然是开放的。前面重点介绍了利用电导测量系统确定相关流率的算法,估计了所得结果的误差,并研究了噪声影响和数据采集时间对结果可靠性的依赖关系。这些工作是使用两个独立的网格传感器进行的,没有涉及局部速度分量的分辨率问题。本工作的目的是测试使用双层网格电导传感器测量时空采样速度的相关方法。结果表明,在准平稳混合条件下,得到了实验模型截面上的流速图,平均流速值与台架标准流量计值吻合较好。在实验的非平稳设置下进行了测量,获得了测点处流量和速度分量的实现。对所得值的分析可以得出相关测量的最佳数据收集时间,以及结果的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of the Correlation Measurement Method for Reconstructing of the Velocity Profile with Spatial and Temporal Discretization in Studies of the Hydrodynamics of Turbulent Flows Based on the Matrix Conductometry Method
The correlation method for measuring of the coolant fl rate is used in the operation of nuclear power plants and is widespread in research practice including study of turbulent fl    hydrodynamics. However the question of its applicability and possibilities in studies using the matrix conductometry method remains open. Earlier the algorithm for determining of the correlation fl rate using a conductometric measuring system was highlighted and the error of the results obtained was estimated and the dependence of the influence of noise and the time of data collection on the reliability of results was investigated. These works were carried out using two independent mesh sensors and the issue of the resolution of local velocity components was not covered. The purpose of this work was to test the correlation method for measuring velocity with temporal and spatial sampling using two-layer mesh conductometric sensors.As the result velocity cartograms were obtained over the cross-section of the experimental model with quasi-stationary mixing and the value of the average flow rate is in good agreement with the values obtained from the standard flow meters of the stand. Also measurements were carried out at a non-stationary setting of the experiment and realizations of the flow rate and velocity components of the flow at the measuring points were obtained.Analysis of the obtained values allows to conclude about the optimal data collection time for correlation measurements, as well as the reliability of results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Devices and Methods of Measurements
Devices and Methods of Measurements INSTRUMENTS & INSTRUMENTATION-
自引率
25.00%
发文量
18
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信