{"title":"多级同步感应线圈枪临界触发判据的研究","authors":"Xiaobo Niu;Lei Chen;Yunzhu An;Yuanchao Hu","doi":"10.1109/TPS.2023.3306329","DOIUrl":null,"url":null,"abstract":"Multistage synchronous induction coilgun (MSSICG) has higher launch efficiency than other electromagnetic guns due to excellent noncontact propulsion characteristics. However, the feeding of the coil array must be synchronized with the movement of the projectile to accelerate the load smoothly. Researchers usually adopt tedious step-by-step debugging to achieve the matching of trigger timing and other structural parameters, but lack of detailed derivation and demonstration of critical trigger criterion. Therefore, starting from the optimal coupling position of single-stage launcher, this article proposes the critical trigger criterion. Then, the extended trigger criterion is modified by analyzing the simplified conditions and adjustable parameters of MSSICG with different structural forms. The research aims to provide reference for the parameter design of MSSICG.","PeriodicalId":450,"journal":{"name":"IEEE Transactions on Plasma Science","volume":"51 9","pages":"2667-2675"},"PeriodicalIF":1.3000,"publicationDate":"2023-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Critical Trigger Criterion of Multistage Synchronous Induction Coilgun\",\"authors\":\"Xiaobo Niu;Lei Chen;Yunzhu An;Yuanchao Hu\",\"doi\":\"10.1109/TPS.2023.3306329\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multistage synchronous induction coilgun (MSSICG) has higher launch efficiency than other electromagnetic guns due to excellent noncontact propulsion characteristics. However, the feeding of the coil array must be synchronized with the movement of the projectile to accelerate the load smoothly. Researchers usually adopt tedious step-by-step debugging to achieve the matching of trigger timing and other structural parameters, but lack of detailed derivation and demonstration of critical trigger criterion. Therefore, starting from the optimal coupling position of single-stage launcher, this article proposes the critical trigger criterion. Then, the extended trigger criterion is modified by analyzing the simplified conditions and adjustable parameters of MSSICG with different structural forms. The research aims to provide reference for the parameter design of MSSICG.\",\"PeriodicalId\":450,\"journal\":{\"name\":\"IEEE Transactions on Plasma Science\",\"volume\":\"51 9\",\"pages\":\"2667-2675\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Plasma Science\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10235297/\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PHYSICS, FLUIDS & PLASMAS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Plasma Science","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/10235297/","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, FLUIDS & PLASMAS","Score":null,"Total":0}
Research on Critical Trigger Criterion of Multistage Synchronous Induction Coilgun
Multistage synchronous induction coilgun (MSSICG) has higher launch efficiency than other electromagnetic guns due to excellent noncontact propulsion characteristics. However, the feeding of the coil array must be synchronized with the movement of the projectile to accelerate the load smoothly. Researchers usually adopt tedious step-by-step debugging to achieve the matching of trigger timing and other structural parameters, but lack of detailed derivation and demonstration of critical trigger criterion. Therefore, starting from the optimal coupling position of single-stage launcher, this article proposes the critical trigger criterion. Then, the extended trigger criterion is modified by analyzing the simplified conditions and adjustable parameters of MSSICG with different structural forms. The research aims to provide reference for the parameter design of MSSICG.
期刊介绍:
The scope covers all aspects of the theory and application of plasma science. It includes the following areas: magnetohydrodynamics; thermionics and plasma diodes; basic plasma phenomena; gaseous electronics; microwave/plasma interaction; electron, ion, and plasma sources; space plasmas; intense electron and ion beams; laser-plasma interactions; plasma diagnostics; plasma chemistry and processing; solid-state plasmas; plasma heating; plasma for controlled fusion research; high energy density plasmas; industrial/commercial applications of plasma physics; plasma waves and instabilities; and high power microwave and submillimeter wave generation.