食品中金属的快速测定方法及其对健康危机的应急响应

IF 0.2 4区 农林科学 Q4 FOOD SCIENCE & TECHNOLOGY
Kyoko Takagi, Hitoshi Miyazaki
{"title":"食品中金属的快速测定方法及其对健康危机的应急响应","authors":"Kyoko Takagi,&nbsp;Hitoshi Miyazaki","doi":"10.3358/shokueishi.63.105","DOIUrl":null,"url":null,"abstract":"<p><p>A rapid determination method for emergency response to health crisis caused by metals in foods, was developed using microwave decomposition equipment and inductively coupled plasma atomic emission spectroscopy (ICP-AES). The method was assessed for 18 elements (Al, As, B, Cd, Co, Cr, Cu, Fe, Hg, Mn, Mo, Ni, Pb, Sb, Se, Sn, Tl and Zn) in 5 kinds of beverages and 7 kinds of foods. A single-laboratory method validation study was performed using food samples added with 20 mg/kg of each metal. Trueness was 88-108% and intralaboratory reproducibility was 0.2-11.3%. Time required for analysis was less than 3 hr. Thus, the presented method could be useful for rapid analysis of metals involved food poisoning cases.</p>","PeriodicalId":54373,"journal":{"name":"Food Hygiene and Safety Science","volume":"63 3","pages":"105-108"},"PeriodicalIF":0.2000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[A Rapid Determination Method of Metals in Foods for Emergency Response to Health Crisis].\",\"authors\":\"Kyoko Takagi,&nbsp;Hitoshi Miyazaki\",\"doi\":\"10.3358/shokueishi.63.105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A rapid determination method for emergency response to health crisis caused by metals in foods, was developed using microwave decomposition equipment and inductively coupled plasma atomic emission spectroscopy (ICP-AES). The method was assessed for 18 elements (Al, As, B, Cd, Co, Cr, Cu, Fe, Hg, Mn, Mo, Ni, Pb, Sb, Se, Sn, Tl and Zn) in 5 kinds of beverages and 7 kinds of foods. A single-laboratory method validation study was performed using food samples added with 20 mg/kg of each metal. Trueness was 88-108% and intralaboratory reproducibility was 0.2-11.3%. Time required for analysis was less than 3 hr. Thus, the presented method could be useful for rapid analysis of metals involved food poisoning cases.</p>\",\"PeriodicalId\":54373,\"journal\":{\"name\":\"Food Hygiene and Safety Science\",\"volume\":\"63 3\",\"pages\":\"105-108\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Hygiene and Safety Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3358/shokueishi.63.105\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Hygiene and Safety Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3358/shokueishi.63.105","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

采用微波分解装置和电感耦合等离子体原子发射光谱(ICP-AES)技术,建立了食品中金属污染健康危机应急快速检测方法。采用该方法对5种饮料和7种食品中的18种元素(Al、As、B、Cd、Co、Cr、Cu、Fe、Hg、Mn、Mo、Ni、Pb、Sb、Se、Sn、Tl、Zn)进行了测定。使用添加每种金属20 mg/kg的食品样品进行了单实验室方法验证研究。准确度为88 ~ 108%,实验室内重现性为0.2 ~ 11.3%。分析所需时间小于3小时。因此,该方法可用于食物中毒案件中金属元素的快速分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[A Rapid Determination Method of Metals in Foods for Emergency Response to Health Crisis].

A rapid determination method for emergency response to health crisis caused by metals in foods, was developed using microwave decomposition equipment and inductively coupled plasma atomic emission spectroscopy (ICP-AES). The method was assessed for 18 elements (Al, As, B, Cd, Co, Cr, Cu, Fe, Hg, Mn, Mo, Ni, Pb, Sb, Se, Sn, Tl and Zn) in 5 kinds of beverages and 7 kinds of foods. A single-laboratory method validation study was performed using food samples added with 20 mg/kg of each metal. Trueness was 88-108% and intralaboratory reproducibility was 0.2-11.3%. Time required for analysis was less than 3 hr. Thus, the presented method could be useful for rapid analysis of metals involved food poisoning cases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Food Hygiene and Safety Science
Food Hygiene and Safety Science Medicine-Public Health, Environmental and Occupational Health
CiteScore
0.70
自引率
0.00%
发文量
28
审稿时长
18-36 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信