{"title":"考虑车站配置的城市地铁系统动态洪水风险建模","authors":"Chen Liang , Mingfu Guan , Kaihua Guo , Dapeng Yu , Jie Yin","doi":"10.1016/j.ress.2025.111760","DOIUrl":null,"url":null,"abstract":"<div><div>Urban flooding poses a significant threat to the operational continuity and safety of metro systems. This study aimed to develop a spatiotemporally dynamic flood risk assessment framework for urban metro systems based on flood modeling. The framework was demonstrated through a case study of the extreme flooding triggered by a record-breaking rainstorm on September 7, 2023, in Hong Kong. A two-dimensional shallow water equations (2D-SWEs) based hydrodynamic model was employed to reproduce the extreme urban flooding, which agrees well with the observed inundation locations. The simulated grid-based inundation was then used to quantify spatiotemporal flood hazard posing to the metro system, with tailored criteria for aboveground, underground, and elevated metro stations. Exposure and vulnerability were assessed by analyzing the construction and operational characteristics of the metro system. By integrating flood hazard, exposure, and vulnerability maps, the spatiotemporal flood risk of Hong Kong's metro system during the historical extreme flood event was comprehensively assessed. In the case study, 46.4% of metro stations were exposed to high or very high flood hazards, while only 29.1% were classified as having high or greater overall flood risk. The temporal analysis further revealed that peak station risk occurred 1–12.5 h after peak rainfall, with an average lag of about 5 h. These findings demonstrate the effectiveness of the proposed framework in capturing the temporal and spatial variability of flood risk at the station scale, providing valuable insights for emergency preparedness and planning.</div></div>","PeriodicalId":54500,"journal":{"name":"Reliability Engineering & System Safety","volume":"266 ","pages":"Article 111760"},"PeriodicalIF":11.0000,"publicationDate":"2025-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic flood risk modeling in urban metro systems considering station configuration\",\"authors\":\"Chen Liang , Mingfu Guan , Kaihua Guo , Dapeng Yu , Jie Yin\",\"doi\":\"10.1016/j.ress.2025.111760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Urban flooding poses a significant threat to the operational continuity and safety of metro systems. This study aimed to develop a spatiotemporally dynamic flood risk assessment framework for urban metro systems based on flood modeling. The framework was demonstrated through a case study of the extreme flooding triggered by a record-breaking rainstorm on September 7, 2023, in Hong Kong. A two-dimensional shallow water equations (2D-SWEs) based hydrodynamic model was employed to reproduce the extreme urban flooding, which agrees well with the observed inundation locations. The simulated grid-based inundation was then used to quantify spatiotemporal flood hazard posing to the metro system, with tailored criteria for aboveground, underground, and elevated metro stations. Exposure and vulnerability were assessed by analyzing the construction and operational characteristics of the metro system. By integrating flood hazard, exposure, and vulnerability maps, the spatiotemporal flood risk of Hong Kong's metro system during the historical extreme flood event was comprehensively assessed. In the case study, 46.4% of metro stations were exposed to high or very high flood hazards, while only 29.1% were classified as having high or greater overall flood risk. The temporal analysis further revealed that peak station risk occurred 1–12.5 h after peak rainfall, with an average lag of about 5 h. These findings demonstrate the effectiveness of the proposed framework in capturing the temporal and spatial variability of flood risk at the station scale, providing valuable insights for emergency preparedness and planning.</div></div>\",\"PeriodicalId\":54500,\"journal\":{\"name\":\"Reliability Engineering & System Safety\",\"volume\":\"266 \",\"pages\":\"Article 111760\"},\"PeriodicalIF\":11.0000,\"publicationDate\":\"2025-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reliability Engineering & System Safety\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0951832025009603\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, INDUSTRIAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reliability Engineering & System Safety","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0951832025009603","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, INDUSTRIAL","Score":null,"Total":0}
Dynamic flood risk modeling in urban metro systems considering station configuration
Urban flooding poses a significant threat to the operational continuity and safety of metro systems. This study aimed to develop a spatiotemporally dynamic flood risk assessment framework for urban metro systems based on flood modeling. The framework was demonstrated through a case study of the extreme flooding triggered by a record-breaking rainstorm on September 7, 2023, in Hong Kong. A two-dimensional shallow water equations (2D-SWEs) based hydrodynamic model was employed to reproduce the extreme urban flooding, which agrees well with the observed inundation locations. The simulated grid-based inundation was then used to quantify spatiotemporal flood hazard posing to the metro system, with tailored criteria for aboveground, underground, and elevated metro stations. Exposure and vulnerability were assessed by analyzing the construction and operational characteristics of the metro system. By integrating flood hazard, exposure, and vulnerability maps, the spatiotemporal flood risk of Hong Kong's metro system during the historical extreme flood event was comprehensively assessed. In the case study, 46.4% of metro stations were exposed to high or very high flood hazards, while only 29.1% were classified as having high or greater overall flood risk. The temporal analysis further revealed that peak station risk occurred 1–12.5 h after peak rainfall, with an average lag of about 5 h. These findings demonstrate the effectiveness of the proposed framework in capturing the temporal and spatial variability of flood risk at the station scale, providing valuable insights for emergency preparedness and planning.
期刊介绍:
Elsevier publishes Reliability Engineering & System Safety in association with the European Safety and Reliability Association and the Safety Engineering and Risk Analysis Division. The international journal is devoted to developing and applying methods to enhance the safety and reliability of complex technological systems, like nuclear power plants, chemical plants, hazardous waste facilities, space systems, offshore and maritime systems, transportation systems, constructed infrastructure, and manufacturing plants. The journal normally publishes only articles that involve the analysis of substantive problems related to the reliability of complex systems or present techniques and/or theoretical results that have a discernable relationship to the solution of such problems. An important aim is to balance academic material and practical applications.