用于太赫兹成像和光谱的远心偏移反射成像系统(TORIS)

IF 3.9 2区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Pouyan Rezapoor;Aleksi Tamminen;Juha Ala-Laurinaho;Dan Ruan;Zachary Taylor
{"title":"用于太赫兹成像和光谱的远心偏移反射成像系统(TORIS)","authors":"Pouyan Rezapoor;Aleksi Tamminen;Juha Ala-Laurinaho;Dan Ruan;Zachary Taylor","doi":"10.1109/TTHZ.2025.3579299","DOIUrl":null,"url":null,"abstract":"Terahertz (THz) imaging has emerged as a promising technology in medical diagnostics, thanks to nonionizing radiation and the high sensitivity of THz waves to water content. However, in vivo, THz imaging system designs face challenges, such as slow mechanical scanning, limited field-of-view, and variable incidence angle due to poor telecentricity. To address these limitations, we present the telecentric offset reflective imaging system, a novel dual-mirror scanning design optimized for high-speed, distortion-free imaging. Utilizing a telecentric <inline-formula><tex-math>$f-\\theta$</tex-math></inline-formula> lens and ray-tracing and physical optics simulations, the system achieves uniform resolution across a 50 × 50 mm<inline-formula><tex-math>$^{2}$</tex-math></inline-formula> field of view. System capability is demonstrated through broadband spectral imaging of a USAF resolution test target across WR-2.2 (325–500 GHz) and WR-1.5 (500–700 GHz) rectangular waveguide frequency bands, achieving consistent beam focus and minimal distortion, with maximum deviation of 2.7<inline-formula><tex-math>$^{\\circ }$</tex-math></inline-formula> from normal incidence and beam waist of 2.1 <inline-formula><tex-math>$\\lambda$</tex-math></inline-formula> at the edge of the field of view. Hydration sensitivity is validated by imaging wet tissue paper, illustrating its sensitivity to temporal changes in water content. Further, in vivo, imaging of human skin after capsaicin patch application reveals localized hydration variations influenced by biochemical responses and adhesive patch removal.","PeriodicalId":13258,"journal":{"name":"IEEE Transactions on Terahertz Science and Technology","volume":"15 5","pages":"787-799"},"PeriodicalIF":3.9000,"publicationDate":"2025-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11031208","citationCount":"0","resultStr":"{\"title\":\"A Telecentric Offset Reflective Imaging System (TORIS) for Terahertz Imaging and Spectroscopy\",\"authors\":\"Pouyan Rezapoor;Aleksi Tamminen;Juha Ala-Laurinaho;Dan Ruan;Zachary Taylor\",\"doi\":\"10.1109/TTHZ.2025.3579299\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Terahertz (THz) imaging has emerged as a promising technology in medical diagnostics, thanks to nonionizing radiation and the high sensitivity of THz waves to water content. However, in vivo, THz imaging system designs face challenges, such as slow mechanical scanning, limited field-of-view, and variable incidence angle due to poor telecentricity. To address these limitations, we present the telecentric offset reflective imaging system, a novel dual-mirror scanning design optimized for high-speed, distortion-free imaging. Utilizing a telecentric <inline-formula><tex-math>$f-\\\\theta$</tex-math></inline-formula> lens and ray-tracing and physical optics simulations, the system achieves uniform resolution across a 50 × 50 mm<inline-formula><tex-math>$^{2}$</tex-math></inline-formula> field of view. System capability is demonstrated through broadband spectral imaging of a USAF resolution test target across WR-2.2 (325–500 GHz) and WR-1.5 (500–700 GHz) rectangular waveguide frequency bands, achieving consistent beam focus and minimal distortion, with maximum deviation of 2.7<inline-formula><tex-math>$^{\\\\circ }$</tex-math></inline-formula> from normal incidence and beam waist of 2.1 <inline-formula><tex-math>$\\\\lambda$</tex-math></inline-formula> at the edge of the field of view. Hydration sensitivity is validated by imaging wet tissue paper, illustrating its sensitivity to temporal changes in water content. Further, in vivo, imaging of human skin after capsaicin patch application reveals localized hydration variations influenced by biochemical responses and adhesive patch removal.\",\"PeriodicalId\":13258,\"journal\":{\"name\":\"IEEE Transactions on Terahertz Science and Technology\",\"volume\":\"15 5\",\"pages\":\"787-799\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2025-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11031208\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Terahertz Science and Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/11031208/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Terahertz Science and Technology","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11031208/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

由于非电离辐射和太赫兹波对水含量的高灵敏度,太赫兹(THz)成像已成为医学诊断中有前途的技术。然而,在体内,太赫兹成像系统的设计面临着挑战,如缓慢的机械扫描,有限的视场,以及由于远心性差而导致的入射角可变。为了解决这些限制,我们提出了远心偏移反射成像系统,这是一种新型的双镜扫描设计,针对高速,无畸变成像进行了优化。利用远心$f-\theta$镜头和光线追踪和物理光学模拟,该系统在50 × 50 mm $^{2}$视场内实现均匀分辨率。通过在WR-2.2 (325-500 GHz)和WR-1.5 (500-700 GHz)矩形波导频带上对USAF分辨率测试目标进行宽带光谱成像,验证了系统的能力,实现了一致的光束聚焦和最小的畸变,与正常入射的最大偏差为2.7 $^{\circ }$,视场边缘的束腰为2.1 $\lambda$。水合敏感性是验证通过成像湿纸巾,说明其敏感性的时间变化的水含量。此外,在体内,辣椒素贴片应用后的人体皮肤成像显示了受生化反应和贴片去除影响的局部水化变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Telecentric Offset Reflective Imaging System (TORIS) for Terahertz Imaging and Spectroscopy
Terahertz (THz) imaging has emerged as a promising technology in medical diagnostics, thanks to nonionizing radiation and the high sensitivity of THz waves to water content. However, in vivo, THz imaging system designs face challenges, such as slow mechanical scanning, limited field-of-view, and variable incidence angle due to poor telecentricity. To address these limitations, we present the telecentric offset reflective imaging system, a novel dual-mirror scanning design optimized for high-speed, distortion-free imaging. Utilizing a telecentric $f-\theta$ lens and ray-tracing and physical optics simulations, the system achieves uniform resolution across a 50 × 50 mm$^{2}$ field of view. System capability is demonstrated through broadband spectral imaging of a USAF resolution test target across WR-2.2 (325–500 GHz) and WR-1.5 (500–700 GHz) rectangular waveguide frequency bands, achieving consistent beam focus and minimal distortion, with maximum deviation of 2.7$^{\circ }$ from normal incidence and beam waist of 2.1 $\lambda$ at the edge of the field of view. Hydration sensitivity is validated by imaging wet tissue paper, illustrating its sensitivity to temporal changes in water content. Further, in vivo, imaging of human skin after capsaicin patch application reveals localized hydration variations influenced by biochemical responses and adhesive patch removal.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Terahertz Science and Technology
IEEE Transactions on Terahertz Science and Technology ENGINEERING, ELECTRICAL & ELECTRONIC-OPTICS
CiteScore
7.10
自引率
9.40%
发文量
102
期刊介绍: IEEE Transactions on Terahertz Science and Technology focuses on original research on Terahertz theory, techniques, and applications as they relate to components, devices, circuits, and systems involving the generation, transmission, and detection of Terahertz waves.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信