{"title":"秀丽隐杆线虫实时表型筛选的线扫描成像技术。","authors":"Aaron Au, Maximiliano Giuliani, Sean Harrington, Peter Roy, Christopher M Yip","doi":"10.1063/5.0238824","DOIUrl":null,"url":null,"abstract":"<p><p>Phenotypic screens of living organisms often require real-time, high spatial resolution imaging. We report here on the design and application of a line-scan imaging platform that enables bright-field imaging of live nematodes using a 96-well plate configuration. The system optics are such that each individual well is projected across the full field of view of a 4 K line scanning camera. To minimize motional artifacts, the camera system is translated, while the sample is kept stationary. We discuss the challenges in establishing flat field illumination, image registration and stitching, and the opportunities that this platform has enabled for phenotypic screens of living systems.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 6","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Line-scan imaging for real-time phenotypic screening of C. elegans.\",\"authors\":\"Aaron Au, Maximiliano Giuliani, Sean Harrington, Peter Roy, Christopher M Yip\",\"doi\":\"10.1063/5.0238824\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Phenotypic screens of living organisms often require real-time, high spatial resolution imaging. We report here on the design and application of a line-scan imaging platform that enables bright-field imaging of live nematodes using a 96-well plate configuration. The system optics are such that each individual well is projected across the full field of view of a 4 K line scanning camera. To minimize motional artifacts, the camera system is translated, while the sample is kept stationary. We discuss the challenges in establishing flat field illumination, image registration and stitching, and the opportunities that this platform has enabled for phenotypic screens of living systems.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":\"96 6\",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0238824\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0238824","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

生物体的表型筛选通常需要实时、高空间分辨率的成像。我们在这里报告了一种线扫描成像平台的设计和应用,该平台可以使用96孔板配置对活线虫进行亮场成像。系统光学是这样的,每个单独的井被投射在一个4 K线扫描相机的整个视野。为了最大限度地减少运动伪影,相机系统被平移,而样品保持静止。我们讨论了在建立平场照明、图像配准和拼接方面的挑战,以及该平台为生命系统的表型筛选提供的机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Line-scan imaging for real-time phenotypic screening of C. elegans.

Phenotypic screens of living organisms often require real-time, high spatial resolution imaging. We report here on the design and application of a line-scan imaging platform that enables bright-field imaging of live nematodes using a 96-well plate configuration. The system optics are such that each individual well is projected across the full field of view of a 4 K line scanning camera. To minimize motional artifacts, the camera system is translated, while the sample is kept stationary. We discuss the challenges in establishing flat field illumination, image registration and stitching, and the opportunities that this platform has enabled for phenotypic screens of living systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信