计算机断层扫描和超声引导机器人辅助腹部幻影和猪肝模型的经皮穿刺

IF 3.8 Q2 ENGINEERING, BIOMEDICAL
Yao Liu;Yong Wang;Jing Xiao;Xu He;Cheng Wang;Jianjun Zhu;Pengju Lv;Huixia Cai;Lige Qiu;Yizhun Zhu;Yong Li;Ligong Lu
{"title":"计算机断层扫描和超声引导机器人辅助腹部幻影和猪肝模型的经皮穿刺","authors":"Yao Liu;Yong Wang;Jing Xiao;Xu He;Cheng Wang;Jianjun Zhu;Pengju Lv;Huixia Cai;Lige Qiu;Yizhun Zhu;Yong Li;Ligong Lu","doi":"10.1109/TMRB.2025.3550644","DOIUrl":null,"url":null,"abstract":"Percutaneous puncture is a pivotal technique in diagnosing and treating hepatic lesions; however, traditional manual puncture methods rely heavily on the expertise of medical practitioners. This study aimed to evaluate the feasibility, safety, and efficacy of percutaneous needle placement through the innovative utilization of computed tomography-ultrasound fusion-guided robotic assistance in abdominal phantom and porcine liver models. The abdominal phantom and eight Bama miniature pigs were selected as experimental subjects. Two puncture methods (handheld and robot-assisted puncture) were administered to each simulated tumor with an 18-gauge biopsy needle. All pigs exhibited stable conditions without any complications following the puncture. The Euclidean distance between the needle tip and the predetermined target point of robot-assisted puncture was <inline-formula> <tex-math>$3.30~\\pm ~1$ </tex-math></inline-formula>.48 mm in the pig model and <inline-formula> <tex-math>$2.15~\\pm ~0$ </tex-math></inline-formula>.82 mm in the phantom model. The planning time required for the physician to perform robot-assisted needle insertion was <inline-formula> <tex-math>$8.25~\\pm ~2.59$ </tex-math></inline-formula> min. Robot-assisted needle insertion in percutaneous puncture was accurate and safe in the pig liver model, highlighting its feasibility and potential clinical application.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":"7 2","pages":"542-549"},"PeriodicalIF":3.8000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computed Tomography and Ultrasound-Guided Robotic Assistance in Percutaneous Puncture in Abdominal Phantom and Porcine Liver Models\",\"authors\":\"Yao Liu;Yong Wang;Jing Xiao;Xu He;Cheng Wang;Jianjun Zhu;Pengju Lv;Huixia Cai;Lige Qiu;Yizhun Zhu;Yong Li;Ligong Lu\",\"doi\":\"10.1109/TMRB.2025.3550644\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Percutaneous puncture is a pivotal technique in diagnosing and treating hepatic lesions; however, traditional manual puncture methods rely heavily on the expertise of medical practitioners. This study aimed to evaluate the feasibility, safety, and efficacy of percutaneous needle placement through the innovative utilization of computed tomography-ultrasound fusion-guided robotic assistance in abdominal phantom and porcine liver models. The abdominal phantom and eight Bama miniature pigs were selected as experimental subjects. Two puncture methods (handheld and robot-assisted puncture) were administered to each simulated tumor with an 18-gauge biopsy needle. All pigs exhibited stable conditions without any complications following the puncture. The Euclidean distance between the needle tip and the predetermined target point of robot-assisted puncture was <inline-formula> <tex-math>$3.30~\\\\pm ~1$ </tex-math></inline-formula>.48 mm in the pig model and <inline-formula> <tex-math>$2.15~\\\\pm ~0$ </tex-math></inline-formula>.82 mm in the phantom model. The planning time required for the physician to perform robot-assisted needle insertion was <inline-formula> <tex-math>$8.25~\\\\pm ~2.59$ </tex-math></inline-formula> min. Robot-assisted needle insertion in percutaneous puncture was accurate and safe in the pig liver model, highlighting its feasibility and potential clinical application.\",\"PeriodicalId\":73318,\"journal\":{\"name\":\"IEEE transactions on medical robotics and bionics\",\"volume\":\"7 2\",\"pages\":\"542-549\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2025-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on medical robotics and bionics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10924276/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10924276/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

经皮穿刺是诊断和治疗肝脏病变的关键技术;然而,传统的手工穿刺方法严重依赖于医生的专业知识。本研究旨在通过创新地利用计算机断层扫描-超声融合引导机器人辅助腹部幻影和猪肝模型,评估经皮置针的可行性、安全性和有效性。选取八头巴马小型猪和腹部幻体作为实验对象。两种穿刺方法(手持式和机器人辅助穿刺)使用18号活检针对每个模拟肿瘤进行穿刺。所有猪穿刺后病情稳定,无任何并发症。机器人辅助穿刺针尖与预定目标点之间的欧氏距离在猪模型中为$3.30~\pm ~1$ 0.48 mm,在幻象模型中为$2.15~\pm ~0$ 0.82 mm。医生实施机器人辅助插针所需的计划时间为8.25美元~2.59美元~ min。机器人辅助插针经皮穿刺在猪肝模型中准确、安全,突出了其可行性和潜在的临床应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computed Tomography and Ultrasound-Guided Robotic Assistance in Percutaneous Puncture in Abdominal Phantom and Porcine Liver Models
Percutaneous puncture is a pivotal technique in diagnosing and treating hepatic lesions; however, traditional manual puncture methods rely heavily on the expertise of medical practitioners. This study aimed to evaluate the feasibility, safety, and efficacy of percutaneous needle placement through the innovative utilization of computed tomography-ultrasound fusion-guided robotic assistance in abdominal phantom and porcine liver models. The abdominal phantom and eight Bama miniature pigs were selected as experimental subjects. Two puncture methods (handheld and robot-assisted puncture) were administered to each simulated tumor with an 18-gauge biopsy needle. All pigs exhibited stable conditions without any complications following the puncture. The Euclidean distance between the needle tip and the predetermined target point of robot-assisted puncture was $3.30~\pm ~1$ .48 mm in the pig model and $2.15~\pm ~0$ .82 mm in the phantom model. The planning time required for the physician to perform robot-assisted needle insertion was $8.25~\pm ~2.59$ min. Robot-assisted needle insertion in percutaneous puncture was accurate and safe in the pig liver model, highlighting its feasibility and potential clinical application.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信