{"title":"基于单片CeBr3晶体的高定位精度编码孔径伽马相机。","authors":"Huixing Gong, Xianchao Huang, Shenghao Fang, Zhuoran Wang, Xiangtao Zeng, Jiajia Zhai, Xiuzuo Liang, Hang Yuan, Shihan Yang, Zhiming Zhang, Long Wei","doi":"10.1063/5.0250404","DOIUrl":null,"url":null,"abstract":"<p><p>A monolithic CeBr3 crystal was utilized in a coded aperture camera system instead of the traditional array-type crystal, leading to enhanced energy resolution and improved accuracy in determining the angular position of the radiation source, particularly for the detection of single-point sources. The dimensions of the monolithic CeBr3 crystal are 26 × 26 × 10 mm3, and it is coupled to an 8 × 8 SiPM array. The coded aperture mask is constructed from tungsten blocks (1.7 × 1.7 × 8 mm3) arranged on a photosensitive resin frame, following a 2 × 2 mosaic of the rank 11 MURA pattern. By utilizing a convolutional neural network, we achieved a spatial resolution of ∼1.2 mm and a depth resolution of ∼2 mm in the CeBr3 crystal. Imaging experiments were conducted using Co-57, Na-22, Cs-137, and Co-60 sources to evaluate the performance of the gamma camera system. With the application of position-segmented energy calibration, we obtained an energy resolution better than 5% @662 keV. The methods of balanced decoding following fine sampling and the weighted averaging after depth of interaction stratification were employed to enhance the positioning accuracy of the radiation source, ultimately attaining an image angular resolution of 5.2° and an angular accuracy of 3.44° with a field of view of 44°.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 5","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High positioning accuracy coded aperture gamma camera based on monolithic CeBr3 crystal.\",\"authors\":\"Huixing Gong, Xianchao Huang, Shenghao Fang, Zhuoran Wang, Xiangtao Zeng, Jiajia Zhai, Xiuzuo Liang, Hang Yuan, Shihan Yang, Zhiming Zhang, Long Wei\",\"doi\":\"10.1063/5.0250404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A monolithic CeBr3 crystal was utilized in a coded aperture camera system instead of the traditional array-type crystal, leading to enhanced energy resolution and improved accuracy in determining the angular position of the radiation source, particularly for the detection of single-point sources. The dimensions of the monolithic CeBr3 crystal are 26 × 26 × 10 mm3, and it is coupled to an 8 × 8 SiPM array. The coded aperture mask is constructed from tungsten blocks (1.7 × 1.7 × 8 mm3) arranged on a photosensitive resin frame, following a 2 × 2 mosaic of the rank 11 MURA pattern. By utilizing a convolutional neural network, we achieved a spatial resolution of ∼1.2 mm and a depth resolution of ∼2 mm in the CeBr3 crystal. Imaging experiments were conducted using Co-57, Na-22, Cs-137, and Co-60 sources to evaluate the performance of the gamma camera system. With the application of position-segmented energy calibration, we obtained an energy resolution better than 5% @662 keV. The methods of balanced decoding following fine sampling and the weighted averaging after depth of interaction stratification were employed to enhance the positioning accuracy of the radiation source, ultimately attaining an image angular resolution of 5.2° and an angular accuracy of 3.44° with a field of view of 44°.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":\"96 5\",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0250404\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0250404","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
High positioning accuracy coded aperture gamma camera based on monolithic CeBr3 crystal.
A monolithic CeBr3 crystal was utilized in a coded aperture camera system instead of the traditional array-type crystal, leading to enhanced energy resolution and improved accuracy in determining the angular position of the radiation source, particularly for the detection of single-point sources. The dimensions of the monolithic CeBr3 crystal are 26 × 26 × 10 mm3, and it is coupled to an 8 × 8 SiPM array. The coded aperture mask is constructed from tungsten blocks (1.7 × 1.7 × 8 mm3) arranged on a photosensitive resin frame, following a 2 × 2 mosaic of the rank 11 MURA pattern. By utilizing a convolutional neural network, we achieved a spatial resolution of ∼1.2 mm and a depth resolution of ∼2 mm in the CeBr3 crystal. Imaging experiments were conducted using Co-57, Na-22, Cs-137, and Co-60 sources to evaluate the performance of the gamma camera system. With the application of position-segmented energy calibration, we obtained an energy resolution better than 5% @662 keV. The methods of balanced decoding following fine sampling and the weighted averaging after depth of interaction stratification were employed to enhance the positioning accuracy of the radiation source, ultimately attaining an image angular resolution of 5.2° and an angular accuracy of 3.44° with a field of view of 44°.
期刊介绍:
Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.