酶触发Au-Se纳米器件用于MicroRNA的精确成像

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Ruyue Wei, Shuqi Wang, Yingbo Pan, Peng Miao, Wei Pan, Na Li, Bo Tang
{"title":"酶触发Au-Se纳米器件用于MicroRNA的精确成像","authors":"Ruyue Wei, Shuqi Wang, Yingbo Pan, Peng Miao, Wei Pan, Na Li, Bo Tang","doi":"10.1021/acs.analchem.5c00395","DOIUrl":null,"url":null,"abstract":"In situ imaging of microRNA (miRNA) in tumor cells is vital for clinical diagnosis and pathological research. However, achieving high-precision imaging is always limited by undesirable background signals. Herein, we introduced a gold–selenium-based nanodevice (AuSeND) for high-fidelity imaging of miRNA via enzyme-triggered catalytic hairpin assembly (CHA). This system employs an enzyme-activatable CHA circuit, constructed by extending a short tail at the 3′ end of hairpin H1 with an apurinic/apyrimidinic (AP) site. The CHA circuit components are connected to the surface of AuNPs via Au–Se bonds, forming a Au–Se nanodevice. It remains inactive in normal cells, while in tumor cells, the CHA circuit is activated by apurinic/apyrimidinic endonuclease 1 (APE1) in the cytoplasm, generating a fluorescence signal under miRNA stimulation for miRNA imaging. The developed AuSeND enables cancer cell-selective miRNA imaging and improves the signal-to-noise ratio by combining the high stability of the Au–Se bond with the specific regulation of the APE1 enzyme, offering strong potential for clinical diagnostic applications.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"4 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Enzyme-Triggered Au–Se Nanodevice for Precise Imaging of MicroRNA\",\"authors\":\"Ruyue Wei, Shuqi Wang, Yingbo Pan, Peng Miao, Wei Pan, Na Li, Bo Tang\",\"doi\":\"10.1021/acs.analchem.5c00395\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In situ imaging of microRNA (miRNA) in tumor cells is vital for clinical diagnosis and pathological research. However, achieving high-precision imaging is always limited by undesirable background signals. Herein, we introduced a gold–selenium-based nanodevice (AuSeND) for high-fidelity imaging of miRNA via enzyme-triggered catalytic hairpin assembly (CHA). This system employs an enzyme-activatable CHA circuit, constructed by extending a short tail at the 3′ end of hairpin H1 with an apurinic/apyrimidinic (AP) site. The CHA circuit components are connected to the surface of AuNPs via Au–Se bonds, forming a Au–Se nanodevice. It remains inactive in normal cells, while in tumor cells, the CHA circuit is activated by apurinic/apyrimidinic endonuclease 1 (APE1) in the cytoplasm, generating a fluorescence signal under miRNA stimulation for miRNA imaging. The developed AuSeND enables cancer cell-selective miRNA imaging and improves the signal-to-noise ratio by combining the high stability of the Au–Se bond with the specific regulation of the APE1 enzyme, offering strong potential for clinical diagnostic applications.\",\"PeriodicalId\":27,\"journal\":{\"name\":\"Analytical Chemistry\",\"volume\":\"4 1\",\"pages\":\"\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2025-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acs.analchem.5c00395\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.5c00395","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

肿瘤细胞microRNA (miRNA)的原位成像对临床诊断和病理研究具有重要意义。然而,实现高精度成像总是受到不良背景信号的限制。在此,我们引入了一种基于金硒的纳米器件(AuSeND),通过酶触发的催化发夹组装(CHA)对miRNA进行高保真成像。该系统采用酶激活的CHA电路,通过在发夹H1的3 '端延伸带有apurinic/apyrimidinic (AP)位点的短尾构建。CHA电路元件通过Au-Se键连接到aunp表面,形成Au-Se纳米器件。在正常细胞中处于失活状态,而在肿瘤细胞中,CHA回路被细胞质中的APE1激活,在miRNA刺激下产生荧光信号,进行miRNA成像。开发的AuSeND通过将Au-Se键的高稳定性与APE1酶的特异性调节相结合,实现了癌细胞选择性miRNA成像,提高了信噪比,具有很强的临床诊断应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

An Enzyme-Triggered Au–Se Nanodevice for Precise Imaging of MicroRNA

An Enzyme-Triggered Au–Se Nanodevice for Precise Imaging of MicroRNA
In situ imaging of microRNA (miRNA) in tumor cells is vital for clinical diagnosis and pathological research. However, achieving high-precision imaging is always limited by undesirable background signals. Herein, we introduced a gold–selenium-based nanodevice (AuSeND) for high-fidelity imaging of miRNA via enzyme-triggered catalytic hairpin assembly (CHA). This system employs an enzyme-activatable CHA circuit, constructed by extending a short tail at the 3′ end of hairpin H1 with an apurinic/apyrimidinic (AP) site. The CHA circuit components are connected to the surface of AuNPs via Au–Se bonds, forming a Au–Se nanodevice. It remains inactive in normal cells, while in tumor cells, the CHA circuit is activated by apurinic/apyrimidinic endonuclease 1 (APE1) in the cytoplasm, generating a fluorescence signal under miRNA stimulation for miRNA imaging. The developed AuSeND enables cancer cell-selective miRNA imaging and improves the signal-to-noise ratio by combining the high stability of the Au–Se bond with the specific regulation of the APE1 enzyme, offering strong potential for clinical diagnostic applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信