{"title":"加入空间能量电荷共享效应模型,实现精确的光子计数 CT 模拟。","authors":"Jiabing Sheng, Dong Zeng, Zhaoying Bian, Mingqiang Li, Yongle Wu, Xin Li, YongShuai Ge, Jianhua Ma","doi":"10.1177/08953996251323725","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> Photon counting CT has demonstrated exceptional performance in spatial resolution, density resolution, and image quality, earning recognition as a groundbreaking technology in medical imaging. However, its technical implementation continues to face substantial challenges, including charge sharing effects.</p><p><strong>Objective: </strong> To develop a spatio-energetic charge-sharing modulation model for accurate photon counting CT simulation (SmuSim). Specifically, SmuSim is built upon the previously developed photon counting toolkit (PcTK) and thoroughly incorporates the charge sharing effects that occur in photon counting CT.</p><p><strong>Methods: </strong> The proposed SmuSim firstly enrolls three primary modules, i.e., photon transport, charge transport, and charge induction to characterize the charge sharing effects in the photon counting CT imaging chain. Then, Monte Carlo simulation is also conducted to validate the feasibility of the proposed SmuSim with well-built charge sharing effects model.</p><p><strong>Results: </strong> Under diverse detector configurations, SmuSim's energy spectrum response curves exhibit a remarkable alignment with Monte Carlo simulations, in stark contrast to the Pctk results. In both digital and clinical phantom studies, SmuSim effectively simulates distorted photon counting CT images. In digital physical phantom simulations, the deviations in attenuation coefficient due to charge sharing effects are -49.70%, -19.66%, and -3.33% for the three energy bins, respectively. In digital clinical phantom simulations, the differences in attenuation coefficient are -19.92%, -4.98%, and -0.6%, respectively. In the two simulation studies, the deviations between the results obtained from SmuSim and those from Monte Carlo simulation are less than 3% and 2%, respectively, demonstrating the effectiveness of the proposed SmuSim.</p><p><strong>Conclusion: </strong> We analyze charge sharing effects in photon counting CT, a comprehensive analytical model, and finally simulate CT images with charge sharing effects for evaluation.</p>","PeriodicalId":49948,"journal":{"name":"Journal of X-Ray Science and Technology","volume":" ","pages":"8953996251323725"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inclusion of spatio-energetic charge sharing effect model for accurate photon counting CT simulation.\",\"authors\":\"Jiabing Sheng, Dong Zeng, Zhaoying Bian, Mingqiang Li, Yongle Wu, Xin Li, YongShuai Ge, Jianhua Ma\",\"doi\":\"10.1177/08953996251323725\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong> Photon counting CT has demonstrated exceptional performance in spatial resolution, density resolution, and image quality, earning recognition as a groundbreaking technology in medical imaging. However, its technical implementation continues to face substantial challenges, including charge sharing effects.</p><p><strong>Objective: </strong> To develop a spatio-energetic charge-sharing modulation model for accurate photon counting CT simulation (SmuSim). Specifically, SmuSim is built upon the previously developed photon counting toolkit (PcTK) and thoroughly incorporates the charge sharing effects that occur in photon counting CT.</p><p><strong>Methods: </strong> The proposed SmuSim firstly enrolls three primary modules, i.e., photon transport, charge transport, and charge induction to characterize the charge sharing effects in the photon counting CT imaging chain. Then, Monte Carlo simulation is also conducted to validate the feasibility of the proposed SmuSim with well-built charge sharing effects model.</p><p><strong>Results: </strong> Under diverse detector configurations, SmuSim's energy spectrum response curves exhibit a remarkable alignment with Monte Carlo simulations, in stark contrast to the Pctk results. In both digital and clinical phantom studies, SmuSim effectively simulates distorted photon counting CT images. In digital physical phantom simulations, the deviations in attenuation coefficient due to charge sharing effects are -49.70%, -19.66%, and -3.33% for the three energy bins, respectively. In digital clinical phantom simulations, the differences in attenuation coefficient are -19.92%, -4.98%, and -0.6%, respectively. In the two simulation studies, the deviations between the results obtained from SmuSim and those from Monte Carlo simulation are less than 3% and 2%, respectively, demonstrating the effectiveness of the proposed SmuSim.</p><p><strong>Conclusion: </strong> We analyze charge sharing effects in photon counting CT, a comprehensive analytical model, and finally simulate CT images with charge sharing effects for evaluation.</p>\",\"PeriodicalId\":49948,\"journal\":{\"name\":\"Journal of X-Ray Science and Technology\",\"volume\":\" \",\"pages\":\"8953996251323725\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of X-Ray Science and Technology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/08953996251323725\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of X-Ray Science and Technology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08953996251323725","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inclusion of spatio-energetic charge sharing effect model for accurate photon counting CT simulation.

Background:  Photon counting CT has demonstrated exceptional performance in spatial resolution, density resolution, and image quality, earning recognition as a groundbreaking technology in medical imaging. However, its technical implementation continues to face substantial challenges, including charge sharing effects.

Objective:  To develop a spatio-energetic charge-sharing modulation model for accurate photon counting CT simulation (SmuSim). Specifically, SmuSim is built upon the previously developed photon counting toolkit (PcTK) and thoroughly incorporates the charge sharing effects that occur in photon counting CT.

Methods:  The proposed SmuSim firstly enrolls three primary modules, i.e., photon transport, charge transport, and charge induction to characterize the charge sharing effects in the photon counting CT imaging chain. Then, Monte Carlo simulation is also conducted to validate the feasibility of the proposed SmuSim with well-built charge sharing effects model.

Results:  Under diverse detector configurations, SmuSim's energy spectrum response curves exhibit a remarkable alignment with Monte Carlo simulations, in stark contrast to the Pctk results. In both digital and clinical phantom studies, SmuSim effectively simulates distorted photon counting CT images. In digital physical phantom simulations, the deviations in attenuation coefficient due to charge sharing effects are -49.70%, -19.66%, and -3.33% for the three energy bins, respectively. In digital clinical phantom simulations, the differences in attenuation coefficient are -19.92%, -4.98%, and -0.6%, respectively. In the two simulation studies, the deviations between the results obtained from SmuSim and those from Monte Carlo simulation are less than 3% and 2%, respectively, demonstrating the effectiveness of the proposed SmuSim.

Conclusion:  We analyze charge sharing effects in photon counting CT, a comprehensive analytical model, and finally simulate CT images with charge sharing effects for evaluation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.90
自引率
23.30%
发文量
150
审稿时长
3 months
期刊介绍: Research areas within the scope of the journal include: Interaction of x-rays with matter: x-ray phenomena, biological effects of radiation, radiation safety and optical constants X-ray sources: x-rays from synchrotrons, x-ray lasers, plasmas, and other sources, conventional or unconventional Optical elements: grazing incidence optics, multilayer mirrors, zone plates, gratings, other diffraction optics Optical instruments: interferometers, spectrometers, microscopes, telescopes, microprobes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信