Linus Leo Stöckli, Mathias Brändli, Daniele Piazza, Rafael Ottersberg, Antoine Pommerol, Axel Murk, Nicolas Thomas
{"title":"低温彗星模拟室太赫兹时域光谱测角仪的设计与调试。","authors":"Linus Leo Stöckli, Mathias Brändli, Daniele Piazza, Rafael Ottersberg, Antoine Pommerol, Axel Murk, Nicolas Thomas","doi":"10.1063/5.0252742","DOIUrl":null,"url":null,"abstract":"<p><p>We present our newly developed laboratory setup, called COCoNuT (Characteristic Observation of Cometary Nuclei using THz-spectroscopy), consisting of a THz spectro-goniometer in a vacuum chamber along with a cryo-cooler intended for cooling down samples rich in ices expected in cometary environments. This setup allows the use of THz time domain spectroscopy on analogs including refractory materials in the spectral range from 0.1 to 5.5 THz with a spectral resolution of up to 0.005 THz. Since the optical setup is mounted on a precision controlled x/y-stage, imaging or spatial averaging can be performed. In this work, we present the design decisions and selection of components. Furthermore, the commissioning of the setup is described and the capabilities are shown. The system can reach pressures of 10-7 mbar and temperatures of 50 K. For 2D scanning, a spatial resolution of 0.3 line-pair per mm is obtained.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 3","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and commissioning of a THz time-domain spectro-goniometer in a cryogenic comet simulation chamber.\",\"authors\":\"Linus Leo Stöckli, Mathias Brändli, Daniele Piazza, Rafael Ottersberg, Antoine Pommerol, Axel Murk, Nicolas Thomas\",\"doi\":\"10.1063/5.0252742\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present our newly developed laboratory setup, called COCoNuT (Characteristic Observation of Cometary Nuclei using THz-spectroscopy), consisting of a THz spectro-goniometer in a vacuum chamber along with a cryo-cooler intended for cooling down samples rich in ices expected in cometary environments. This setup allows the use of THz time domain spectroscopy on analogs including refractory materials in the spectral range from 0.1 to 5.5 THz with a spectral resolution of up to 0.005 THz. Since the optical setup is mounted on a precision controlled x/y-stage, imaging or spatial averaging can be performed. In this work, we present the design decisions and selection of components. Furthermore, the commissioning of the setup is described and the capabilities are shown. The system can reach pressures of 10-7 mbar and temperatures of 50 K. For 2D scanning, a spatial resolution of 0.3 line-pair per mm is obtained.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":\"96 3\",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0252742\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0252742","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Design and commissioning of a THz time-domain spectro-goniometer in a cryogenic comet simulation chamber.
We present our newly developed laboratory setup, called COCoNuT (Characteristic Observation of Cometary Nuclei using THz-spectroscopy), consisting of a THz spectro-goniometer in a vacuum chamber along with a cryo-cooler intended for cooling down samples rich in ices expected in cometary environments. This setup allows the use of THz time domain spectroscopy on analogs including refractory materials in the spectral range from 0.1 to 5.5 THz with a spectral resolution of up to 0.005 THz. Since the optical setup is mounted on a precision controlled x/y-stage, imaging or spatial averaging can be performed. In this work, we present the design decisions and selection of components. Furthermore, the commissioning of the setup is described and the capabilities are shown. The system can reach pressures of 10-7 mbar and temperatures of 50 K. For 2D scanning, a spatial resolution of 0.3 line-pair per mm is obtained.
期刊介绍:
Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.