IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
Kaiqiang Ye, Youlin Xu, Jiaqiang Zheng
{"title":"Real-time online resonance frequency tuning of piezoelectric ultrasonic transducer through nesting Terfenol-D into composite horn.","authors":"Kaiqiang Ye, Youlin Xu, Jiaqiang Zheng","doi":"10.1063/5.0235900","DOIUrl":null,"url":null,"abstract":"<p><p>To address the challenge of quickly tuning the resonance frequency of ultrasonic transducers in real-time after manufacturing, this paper proposes integrating Terfenol-D into the horn of a piezoelectric ultrasonic transducer. In practical applications, the transducer is mechanically excited by a piezoelectric vibrator connected to an alternating current power supply, while the Terfenol-D is surrounded by a coil connected to a direct current power supply. By utilizing the delta-E (ΔE) effect of Terfenol-D, the modulus of the material changes in response to variations in the surrounding magnetic field, enabling real-time online adjustment of the resonance frequency. The resonance frequency and amplification coefficient of the transducer were analyzed using the transfer matrix method. Then, an impedance analyzer was employed to measure changes in the transducer's impedance and resonance frequency under different electric currents. Experimental results demonstrate that the resonance frequency of the transducer increases with increasing electric current. The developed piezoelectric ultrasonic transducer, featuring Terfenol-D embedded in the horn, achieves rapid and real-time resonance frequency adjustment within a specific range. This innovation provides a novel solution for complex ultrasonic application scenarios requiring frequent transducer replacements.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"96 2","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0235900","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

为了解决超声波换能器制造后实时快速调整共振频率的难题,本文建议将 Terfenol-D 集成到压电超声波换能器的喇叭中。在实际应用中,换能器由连接交流电源的压电振动器进行机械激励,而 Terfenol-D 则由连接直流电源的线圈包围。通过利用 Terfenol-D 的ΔE(ΔE)效应,材料的模量会随着周围磁场的变化而变化,从而实现共振频率的实时在线调整。利用传递矩阵法分析了传感器的共振频率和放大系数。然后,使用阻抗分析仪测量了不同电流下传感器阻抗和共振频率的变化。实验结果表明,换能器的共振频率随着电流的增加而增加。所开发的压电超声换能器在喇叭中嵌入了 Terfenol-D,可在特定范围内实现快速、实时的共振频率调节。这一创新为需要频繁更换换能器的复杂超声波应用场景提供了新颖的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real-time online resonance frequency tuning of piezoelectric ultrasonic transducer through nesting Terfenol-D into composite horn.

To address the challenge of quickly tuning the resonance frequency of ultrasonic transducers in real-time after manufacturing, this paper proposes integrating Terfenol-D into the horn of a piezoelectric ultrasonic transducer. In practical applications, the transducer is mechanically excited by a piezoelectric vibrator connected to an alternating current power supply, while the Terfenol-D is surrounded by a coil connected to a direct current power supply. By utilizing the delta-E (ΔE) effect of Terfenol-D, the modulus of the material changes in response to variations in the surrounding magnetic field, enabling real-time online adjustment of the resonance frequency. The resonance frequency and amplification coefficient of the transducer were analyzed using the transfer matrix method. Then, an impedance analyzer was employed to measure changes in the transducer's impedance and resonance frequency under different electric currents. Experimental results demonstrate that the resonance frequency of the transducer increases with increasing electric current. The developed piezoelectric ultrasonic transducer, featuring Terfenol-D embedded in the horn, achieves rapid and real-time resonance frequency adjustment within a specific range. This innovation provides a novel solution for complex ultrasonic application scenarios requiring frequent transducer replacements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信