{"title":"不同类型复合树脂在初级磨牙模腔中的应力分布研究。","authors":"Selin Acar, Cigdem Guler, Mehmet Sami Guler, Muhammed Latif Bekci","doi":"10.1080/10255842.2025.2465339","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study is to examine the mechanical behavior of different types of composite resins (short fiber-reinforced composite, conventional high-fill hybrid composite and bulk-fill composite) used in the restoration of class II MOD cavities of primary molar teeth by the finite element analysis (FEA). Three three-dimensional tooth models were created in a computer environment. Model 1: tooth model without restoration (control group), Model 2: class II MOD cavity tooth model restored using composite resin (incremental technique), and Model 3: class II MOD cavity tooth model restored using composite resin (bulk technique). Subgroups were formed using the properties of different types of composite resins tested in the class II MOD cavity tooth model. To simulate the average bite force in a child with primary dentition, vertical static loading of 245 N was applied to each of the occlusal contact points of the models. The maximum von Mises stress values were calculated for the models. For all models, the von Mises stress values obtained in enamel were higher than those obtained in dentin. Similar von Mises stress values were obtained in all subgroups of Model 2. The lowest von Mises stress values transmitted to the dental tissues were obtained in Model 3.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":" ","pages":"1-10"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of stress distribution of different types of composite resins in mod cavities of primary molar teeth.\",\"authors\":\"Selin Acar, Cigdem Guler, Mehmet Sami Guler, Muhammed Latif Bekci\",\"doi\":\"10.1080/10255842.2025.2465339\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study is to examine the mechanical behavior of different types of composite resins (short fiber-reinforced composite, conventional high-fill hybrid composite and bulk-fill composite) used in the restoration of class II MOD cavities of primary molar teeth by the finite element analysis (FEA). Three three-dimensional tooth models were created in a computer environment. Model 1: tooth model without restoration (control group), Model 2: class II MOD cavity tooth model restored using composite resin (incremental technique), and Model 3: class II MOD cavity tooth model restored using composite resin (bulk technique). Subgroups were formed using the properties of different types of composite resins tested in the class II MOD cavity tooth model. To simulate the average bite force in a child with primary dentition, vertical static loading of 245 N was applied to each of the occlusal contact points of the models. The maximum von Mises stress values were calculated for the models. For all models, the von Mises stress values obtained in enamel were higher than those obtained in dentin. Similar von Mises stress values were obtained in all subgroups of Model 2. The lowest von Mises stress values transmitted to the dental tissues were obtained in Model 3.</p>\",\"PeriodicalId\":50640,\"journal\":{\"name\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"volume\":\" \",\"pages\":\"1-10\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-02-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10255842.2025.2465339\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2025.2465339","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

摘要

采用有限元分析的方法,研究了短纤维增强复合材料、常规高填充复合材料和大块填充复合材料在修复初级磨牙ⅱ类MOD牙槽中的力学行为。在计算机环境中创建了三个三维牙齿模型。模型1:未修复牙齿模型(对照组),模型2:复合树脂修复II类MOD腔体牙齿模型(增量技术),模型3:复合树脂修复II类MOD腔体牙齿模型(散装技术)。在II类MOD牙洞模型中测试不同类型复合树脂的性能,形成亚组。为了模拟初生牙列儿童的平均咬合力,对模型的每个咬合接触点施加245 N的垂直静载荷。计算了模型的最大von Mises应力值。所有模型的von Mises应力值均高于牙本质的von Mises应力值。模型2各亚组的von Mises应力值相似。传递到牙组织的最小von Mises应力值由模型3得到。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of stress distribution of different types of composite resins in mod cavities of primary molar teeth.

The aim of this study is to examine the mechanical behavior of different types of composite resins (short fiber-reinforced composite, conventional high-fill hybrid composite and bulk-fill composite) used in the restoration of class II MOD cavities of primary molar teeth by the finite element analysis (FEA). Three three-dimensional tooth models were created in a computer environment. Model 1: tooth model without restoration (control group), Model 2: class II MOD cavity tooth model restored using composite resin (incremental technique), and Model 3: class II MOD cavity tooth model restored using composite resin (bulk technique). Subgroups were formed using the properties of different types of composite resins tested in the class II MOD cavity tooth model. To simulate the average bite force in a child with primary dentition, vertical static loading of 245 N was applied to each of the occlusal contact points of the models. The maximum von Mises stress values were calculated for the models. For all models, the von Mises stress values obtained in enamel were higher than those obtained in dentin. Similar von Mises stress values were obtained in all subgroups of Model 2. The lowest von Mises stress values transmitted to the dental tissues were obtained in Model 3.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信