{"title":"新型光膜传感器测定草甘膦","authors":"Sabiha Elif Ekerim, Neşe Taşci, Melike Fırlak Demirkan","doi":"10.1016/j.foodchem.2025.143361","DOIUrl":null,"url":null,"abstract":"<div><div>Glyphosate has been a widely used herbicide since the 1970s. However, glyphosate causes serious health problems if exposed to it for a long time. Therefore, quick and reliable determination of glyphosate becomes an important issue. This study proposes a solution to this issue with a highly selective and sensitive fluorescent polymeric membrane sensor for glyphosate determination with a wide linear working range (1–18 ppb) and low detection limit (0.84 ppb). The developed sensor can measure glyphosate at pH 8.0 and is applicable to real samples with recovery percentages varying between 98.4 and 111.5. Additionally, this sensor can respond in a short time and can be reused up to 200 times. The repeatability of the method was found to be 10.47 ± 0.11 at a 95 % confidence level and the relative standard deviation was 1.76 for the analysis results of 10 ppb samples. All these features make proposed method, an ambitious alternative tool for glyphosate detection.</div></div>","PeriodicalId":318,"journal":{"name":"Food Chemistry","volume":"475 ","pages":"Article 143361"},"PeriodicalIF":9.8000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of glyphosate with a novel optic membrane sensor\",\"authors\":\"Sabiha Elif Ekerim, Neşe Taşci, Melike Fırlak Demirkan\",\"doi\":\"10.1016/j.foodchem.2025.143361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Glyphosate has been a widely used herbicide since the 1970s. However, glyphosate causes serious health problems if exposed to it for a long time. Therefore, quick and reliable determination of glyphosate becomes an important issue. This study proposes a solution to this issue with a highly selective and sensitive fluorescent polymeric membrane sensor for glyphosate determination with a wide linear working range (1–18 ppb) and low detection limit (0.84 ppb). The developed sensor can measure glyphosate at pH 8.0 and is applicable to real samples with recovery percentages varying between 98.4 and 111.5. Additionally, this sensor can respond in a short time and can be reused up to 200 times. The repeatability of the method was found to be 10.47 ± 0.11 at a 95 % confidence level and the relative standard deviation was 1.76 for the analysis results of 10 ppb samples. All these features make proposed method, an ambitious alternative tool for glyphosate detection.</div></div>\",\"PeriodicalId\":318,\"journal\":{\"name\":\"Food Chemistry\",\"volume\":\"475 \",\"pages\":\"Article 143361\"},\"PeriodicalIF\":9.8000,\"publicationDate\":\"2025-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Chemistry\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0308814625006120\",\"RegionNum\":1,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Chemistry","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0308814625006120","RegionNum":1,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
Determination of glyphosate with a novel optic membrane sensor
Glyphosate has been a widely used herbicide since the 1970s. However, glyphosate causes serious health problems if exposed to it for a long time. Therefore, quick and reliable determination of glyphosate becomes an important issue. This study proposes a solution to this issue with a highly selective and sensitive fluorescent polymeric membrane sensor for glyphosate determination with a wide linear working range (1–18 ppb) and low detection limit (0.84 ppb). The developed sensor can measure glyphosate at pH 8.0 and is applicable to real samples with recovery percentages varying between 98.4 and 111.5. Additionally, this sensor can respond in a short time and can be reused up to 200 times. The repeatability of the method was found to be 10.47 ± 0.11 at a 95 % confidence level and the relative standard deviation was 1.76 for the analysis results of 10 ppb samples. All these features make proposed method, an ambitious alternative tool for glyphosate detection.
期刊介绍:
Food Chemistry publishes original research papers dealing with the advancement of the chemistry and biochemistry of foods or the analytical methods/ approach used. All papers should focus on the novelty of the research carried out.