均质技术和条件对酪蛋白水解物双乳中油包水乳状液影响的比较研究

IF 3.5 2区 农林科学 Q2 FOOD SCIENCE & TECHNOLOGY
Pelin Salum, Çağla Ulubaş, Onur Güven, Mustafa Cam, Levent Yurdaer Aydemir, Zafer Erbay
{"title":"均质技术和条件对酪蛋白水解物双乳中油包水乳状液影响的比较研究","authors":"Pelin Salum,&nbsp;Çağla Ulubaş,&nbsp;Onur Güven,&nbsp;Mustafa Cam,&nbsp;Levent Yurdaer Aydemir,&nbsp;Zafer Erbay","doi":"10.1002/fsn3.4525","DOIUrl":null,"url":null,"abstract":"<p>This study aims to evaluate homogenization techniques and conditions for producing stable, small droplet-size water-in-oil (W/O) emulsions intended for incorporation into casein hydrolysate–loaded double emulsions. Three commonly used homogenization methods; rotor–stator, ultrasonic, and high-pressure homogenization were individually optimized utilizing response surface methodology. Instances of over-processing were observed, particularly with the rotor–stator and ultrasonic homogenizers under specific conditions. Nevertheless, optimal conditions were identified for each technique: 530 s at 17,800 rpm agitation speed for the rotor–stator homogenizer, 139 s at 39% amplitude for the ultrasonic homogenizer, and 520 s at 1475 bar for the high-pressure homogenizer. Subsequently, the W/O emulsions produced under optimal conditions and their respective W<sub>1</sub>/O/W<sub>2</sub> double emulsions were compared. The rotor–stator and high-pressure homogenized W/O emulsions exhibited comparable narrow droplet-size distributions, as indicated by similar Span values. However, high-pressure homogenization failed to sufficiently minimize droplet size. Ultrasonic homogenization resulted in droplets at the 1-μm scale but yielded more polydisperse droplet-size distribution. According to TOPSIS analysis, an emulsion with a viscosity of 93.1 cP (centiPoise), a stability index of 93.8%, a D(90) of 0.67 μm (0th day), and a D(90) of 0.75 μm (30th day) produced using a rotor–stator was selected. Additionally, double emulsions containing primary emulsions prepared with the rotor–stator method demonstrated higher viscosity, narrower droplet-size distribution, and lower creaming compared to other samples. This investigation sheds light on the influence of homogenization techniques on emulsion properties, providing valuable insights for optimizing double emulsion formulations.</p>","PeriodicalId":12418,"journal":{"name":"Food Science & Nutrition","volume":"12 11","pages":"9585-9599"},"PeriodicalIF":3.5000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/fsn3.4525","citationCount":"0","resultStr":"{\"title\":\"The Impact of Homogenization Techniques and Conditions on Water-In-Oil Emulsions for Casein Hydrolysate–Loaded Double Emulsions: A Comparative Study\",\"authors\":\"Pelin Salum,&nbsp;Çağla Ulubaş,&nbsp;Onur Güven,&nbsp;Mustafa Cam,&nbsp;Levent Yurdaer Aydemir,&nbsp;Zafer Erbay\",\"doi\":\"10.1002/fsn3.4525\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This study aims to evaluate homogenization techniques and conditions for producing stable, small droplet-size water-in-oil (W/O) emulsions intended for incorporation into casein hydrolysate–loaded double emulsions. Three commonly used homogenization methods; rotor–stator, ultrasonic, and high-pressure homogenization were individually optimized utilizing response surface methodology. Instances of over-processing were observed, particularly with the rotor–stator and ultrasonic homogenizers under specific conditions. Nevertheless, optimal conditions were identified for each technique: 530 s at 17,800 rpm agitation speed for the rotor–stator homogenizer, 139 s at 39% amplitude for the ultrasonic homogenizer, and 520 s at 1475 bar for the high-pressure homogenizer. Subsequently, the W/O emulsions produced under optimal conditions and their respective W<sub>1</sub>/O/W<sub>2</sub> double emulsions were compared. The rotor–stator and high-pressure homogenized W/O emulsions exhibited comparable narrow droplet-size distributions, as indicated by similar Span values. However, high-pressure homogenization failed to sufficiently minimize droplet size. Ultrasonic homogenization resulted in droplets at the 1-μm scale but yielded more polydisperse droplet-size distribution. According to TOPSIS analysis, an emulsion with a viscosity of 93.1 cP (centiPoise), a stability index of 93.8%, a D(90) of 0.67 μm (0th day), and a D(90) of 0.75 μm (30th day) produced using a rotor–stator was selected. Additionally, double emulsions containing primary emulsions prepared with the rotor–stator method demonstrated higher viscosity, narrower droplet-size distribution, and lower creaming compared to other samples. This investigation sheds light on the influence of homogenization techniques on emulsion properties, providing valuable insights for optimizing double emulsion formulations.</p>\",\"PeriodicalId\":12418,\"journal\":{\"name\":\"Food Science & Nutrition\",\"volume\":\"12 11\",\"pages\":\"9585-9599\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/fsn3.4525\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Science & Nutrition\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/fsn3.4525\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Science & Nutrition","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/fsn3.4525","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估均质技术和条件,以生产稳定的、小液滴大小的油包水(W/O)乳剂,并将其掺入含有酪蛋白水解物的双乳剂中。三种常用的均质方法;利用响应面法分别对转子-定子、超声波和高压均质进行了优化。观察到过度处理的实例,特别是在特定条件下的转子-定子和超声波均质机。然而,每种技术都确定了最佳条件:转子-定子均质器在17,800 rpm的搅拌速度下搅拌530秒,超声波均质器在39%振幅下搅拌139秒,高压均质器在1475 bar的搅拌速度下搅拌520秒。随后,比较了最优条件下制备的W/O乳剂及其各自的W1/O/W2双乳剂。通过相似的Span值可以看出,转子-定子和高压均质W/O乳液的液滴尺寸分布相当窄。然而,高压均质不能充分减小液滴尺寸。超声均质化后的液滴尺寸为1 μm,但液滴尺寸分布更为分散。根据TOPSIS分析,选择了粘度为93.1 cP (centiPoise)、稳定性指数为93.8%、D(90)为0.67 μm(第0天)、D(90)为0.75 μm(第30天)的转子-定子乳液。此外,与其他样品相比,采用转子-定子方法制备的含有初级乳状液的双乳具有更高的粘度、更窄的液滴尺寸分布和更低的乳化。本研究揭示了均质技术对乳液性能的影响,为优化双乳液配方提供了有价值的见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The Impact of Homogenization Techniques and Conditions on Water-In-Oil Emulsions for Casein Hydrolysate–Loaded Double Emulsions: A Comparative Study

The Impact of Homogenization Techniques and Conditions on Water-In-Oil Emulsions for Casein Hydrolysate–Loaded Double Emulsions: A Comparative Study

This study aims to evaluate homogenization techniques and conditions for producing stable, small droplet-size water-in-oil (W/O) emulsions intended for incorporation into casein hydrolysate–loaded double emulsions. Three commonly used homogenization methods; rotor–stator, ultrasonic, and high-pressure homogenization were individually optimized utilizing response surface methodology. Instances of over-processing were observed, particularly with the rotor–stator and ultrasonic homogenizers under specific conditions. Nevertheless, optimal conditions were identified for each technique: 530 s at 17,800 rpm agitation speed for the rotor–stator homogenizer, 139 s at 39% amplitude for the ultrasonic homogenizer, and 520 s at 1475 bar for the high-pressure homogenizer. Subsequently, the W/O emulsions produced under optimal conditions and their respective W1/O/W2 double emulsions were compared. The rotor–stator and high-pressure homogenized W/O emulsions exhibited comparable narrow droplet-size distributions, as indicated by similar Span values. However, high-pressure homogenization failed to sufficiently minimize droplet size. Ultrasonic homogenization resulted in droplets at the 1-μm scale but yielded more polydisperse droplet-size distribution. According to TOPSIS analysis, an emulsion with a viscosity of 93.1 cP (centiPoise), a stability index of 93.8%, a D(90) of 0.67 μm (0th day), and a D(90) of 0.75 μm (30th day) produced using a rotor–stator was selected. Additionally, double emulsions containing primary emulsions prepared with the rotor–stator method demonstrated higher viscosity, narrower droplet-size distribution, and lower creaming compared to other samples. This investigation sheds light on the influence of homogenization techniques on emulsion properties, providing valuable insights for optimizing double emulsion formulations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Food Science & Nutrition
Food Science & Nutrition Agricultural and Biological Sciences-Food Science
CiteScore
7.40
自引率
5.10%
发文量
434
审稿时长
24 weeks
期刊介绍: Food Science & Nutrition is the peer-reviewed journal for rapid dissemination of research in all areas of food science and nutrition. The Journal will consider submissions of quality papers describing the results of fundamental and applied research related to all aspects of human food and nutrition, as well as interdisciplinary research that spans these two fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信