{"title":"一种由缺氧和粘性环境激活的串联锁定荧光探针,用于术中精确成像肿瘤和即时评估铁蛋白沉积诱导的治疗。","authors":"Jiao Lu, Guiling Zhao, Yonghai Wang, Rui Wang, Yanlong Xing, Fabiao Yu, Kun Dou","doi":"10.1021/acs.analchem.4c04820","DOIUrl":null,"url":null,"abstract":"<p><p>Noninvasive fluorescence detection of tumor-associated biomarker dynamics provides immediate insights into tumor biology, which are essential for assessing the efficacy of therapeutic interventions, adapting treatment strategies, and achieving personalized diagnosis and therapy evaluation. However, due to the absence of a single biomarker that effectively reflects tumor development and progression, the currently available optical diagnostic agents that rely on \"always-on\" or single pathological activation frequently show nonspecific fluorescence responses and limited tumor accumulation, which inevitably compromises the accuracy and reliability of tumor imaging. Herein, based on intramolecular charge transfer (ICT) and twisted intramolecular charge-transfer (TICT) hybrid mechanisms, we report a tandem-locked probe, <b>NTVI-Biotin</b>, for simultaneously specific imaging-guided tumor resection and ferroptosis-mediated tumor ablation evaluation under the coactivation of nitro reductase (NTR)/viscosity. The dual-stimulus-responsive design strategy ensures that <b>NTVI-Biotin</b> exclusively activates near-infrared (NIR) fluorescence signals upon interaction with both NTR and elevated viscosity levels through triggering ICT on while inhibiting the TICT process. Meanwhile, functionalization with a tumor-targeting hydrophilic biotin-poly(ethylene glycol) moiety enhances tumor accumulation. The probe's dual-response and tumor-targeting design minimizes nonspecific tissue activation, allowing for precise tumor identification and lesion removal with a superior tumor-to-normal tissue (T/N > 6) ratio. More importantly, <b>NTVI-Biotin</b> was capable of evaluating ferroptosis-mediated chemotherapeutics by real-time monitoring of the alternations of NTR/viscosity levels. The results reveal that the increased tumor signals of <b>NTVI-Biotin</b> following the combination of ferroptosis and chemotherapy correlate well with the tumor growth inhibition, demonstrating the potential of <b>NTVI-Biotin</b> to assess therapeutic efficacy.</p>","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":" ","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Tandem-Locked Fluorescent Probe Activated by Hypoxia and a Viscous Environment for Precise Intraoperative Imaging of Tumor and Instant Assessment of Ferroptosis-Mediated Therapy.\",\"authors\":\"Jiao Lu, Guiling Zhao, Yonghai Wang, Rui Wang, Yanlong Xing, Fabiao Yu, Kun Dou\",\"doi\":\"10.1021/acs.analchem.4c04820\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Noninvasive fluorescence detection of tumor-associated biomarker dynamics provides immediate insights into tumor biology, which are essential for assessing the efficacy of therapeutic interventions, adapting treatment strategies, and achieving personalized diagnosis and therapy evaluation. However, due to the absence of a single biomarker that effectively reflects tumor development and progression, the currently available optical diagnostic agents that rely on \\\"always-on\\\" or single pathological activation frequently show nonspecific fluorescence responses and limited tumor accumulation, which inevitably compromises the accuracy and reliability of tumor imaging. Herein, based on intramolecular charge transfer (ICT) and twisted intramolecular charge-transfer (TICT) hybrid mechanisms, we report a tandem-locked probe, <b>NTVI-Biotin</b>, for simultaneously specific imaging-guided tumor resection and ferroptosis-mediated tumor ablation evaluation under the coactivation of nitro reductase (NTR)/viscosity. The dual-stimulus-responsive design strategy ensures that <b>NTVI-Biotin</b> exclusively activates near-infrared (NIR) fluorescence signals upon interaction with both NTR and elevated viscosity levels through triggering ICT on while inhibiting the TICT process. Meanwhile, functionalization with a tumor-targeting hydrophilic biotin-poly(ethylene glycol) moiety enhances tumor accumulation. The probe's dual-response and tumor-targeting design minimizes nonspecific tissue activation, allowing for precise tumor identification and lesion removal with a superior tumor-to-normal tissue (T/N > 6) ratio. More importantly, <b>NTVI-Biotin</b> was capable of evaluating ferroptosis-mediated chemotherapeutics by real-time monitoring of the alternations of NTR/viscosity levels. The results reveal that the increased tumor signals of <b>NTVI-Biotin</b> following the combination of ferroptosis and chemotherapy correlate well with the tumor growth inhibition, demonstrating the potential of <b>NTVI-Biotin</b> to assess therapeutic efficacy.</p>\",\"PeriodicalId\":27,\"journal\":{\"name\":\"Analytical Chemistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acs.analchem.4c04820\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c04820","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
A Tandem-Locked Fluorescent Probe Activated by Hypoxia and a Viscous Environment for Precise Intraoperative Imaging of Tumor and Instant Assessment of Ferroptosis-Mediated Therapy.
Noninvasive fluorescence detection of tumor-associated biomarker dynamics provides immediate insights into tumor biology, which are essential for assessing the efficacy of therapeutic interventions, adapting treatment strategies, and achieving personalized diagnosis and therapy evaluation. However, due to the absence of a single biomarker that effectively reflects tumor development and progression, the currently available optical diagnostic agents that rely on "always-on" or single pathological activation frequently show nonspecific fluorescence responses and limited tumor accumulation, which inevitably compromises the accuracy and reliability of tumor imaging. Herein, based on intramolecular charge transfer (ICT) and twisted intramolecular charge-transfer (TICT) hybrid mechanisms, we report a tandem-locked probe, NTVI-Biotin, for simultaneously specific imaging-guided tumor resection and ferroptosis-mediated tumor ablation evaluation under the coactivation of nitro reductase (NTR)/viscosity. The dual-stimulus-responsive design strategy ensures that NTVI-Biotin exclusively activates near-infrared (NIR) fluorescence signals upon interaction with both NTR and elevated viscosity levels through triggering ICT on while inhibiting the TICT process. Meanwhile, functionalization with a tumor-targeting hydrophilic biotin-poly(ethylene glycol) moiety enhances tumor accumulation. The probe's dual-response and tumor-targeting design minimizes nonspecific tissue activation, allowing for precise tumor identification and lesion removal with a superior tumor-to-normal tissue (T/N > 6) ratio. More importantly, NTVI-Biotin was capable of evaluating ferroptosis-mediated chemotherapeutics by real-time monitoring of the alternations of NTR/viscosity levels. The results reveal that the increased tumor signals of NTVI-Biotin following the combination of ferroptosis and chemotherapy correlate well with the tumor growth inhibition, demonstrating the potential of NTVI-Biotin to assess therapeutic efficacy.
期刊介绍:
Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.