利用有限元分析评估钛和碳纤维增强聚醚醚酮迷你钢板在 Le Fort I 型推进截骨固定中的生物力学效应和稳定性。

IF 2.2 3区 医学 Q2 Dentistry
Kübra Yakut, Sezai Çiftçi
{"title":"利用有限元分析评估钛和碳纤维增强聚醚醚酮迷你钢板在 Le Fort I 型推进截骨固定中的生物力学效应和稳定性。","authors":"Kübra Yakut, Sezai Çiftçi","doi":"10.1016/j.jormas.2024.102153","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study aimed to investigate the biomechanical properties of 60 % carbon fiber-reinforced polyetheretherketone (Cfr-PEEK), which exhibits high mechanical strength and can address the limitations of titanium mini plates used in Le Fort I osteotomy.</p><p><strong>Material and method: </strong>Models were created using the FEA method based on tomography images of adult individuals. A 5 mm maxillary advancement was applied to the models following Le Fort I osteotomy. Mini plates made of titanium and 60 % Cfr-PEEK were used. Support was provided by the nasomaxillary and zygomaticomaxillary buttresses to fix a total of four l-shaped mini plates. Oblique loads of 125 N, directed from palatal to buccal, and a total of 250 N compression loads were applied to the central fossa of the premolar and molar teeth in the maxillary model at a 30° angle relative to the long axis of the teeth. Displacement values at the osteotomy line, Von Mises stresses in the mini plate-screws, and principal stresses in the bone were compared.</p><p><strong>Results: </strong>Examination of stress values in the fixation systems of the models revealed higher stress values in the Cfr-PEEK model compared to the titanium model. However, these stresses did not reach levels that would deform the Cfr-PEEK fixation systems. Stress and displacement values in the bone were lower in the Cfr-PEEK model compared to the titanium model.</p><p><strong>Conclusion: </strong>According to the findings of our study, Cfr-PEEK represents a viable alternative to titanium for mini plate material in Le Fort I osteotomy, offering biomechanical advantages.</p>","PeriodicalId":56038,"journal":{"name":"Journal of Stomatology Oral and Maxillofacial Surgery","volume":" ","pages":"102153"},"PeriodicalIF":2.2000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the biomechanical effects and stability of titanium and carbon fiber-reinforced polyetheretherketone mini plates in Le Fort I advancement osteotomy fixation using finite element analysis.\",\"authors\":\"Kübra Yakut, Sezai Çiftçi\",\"doi\":\"10.1016/j.jormas.2024.102153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>This study aimed to investigate the biomechanical properties of 60 % carbon fiber-reinforced polyetheretherketone (Cfr-PEEK), which exhibits high mechanical strength and can address the limitations of titanium mini plates used in Le Fort I osteotomy.</p><p><strong>Material and method: </strong>Models were created using the FEA method based on tomography images of adult individuals. A 5 mm maxillary advancement was applied to the models following Le Fort I osteotomy. Mini plates made of titanium and 60 % Cfr-PEEK were used. Support was provided by the nasomaxillary and zygomaticomaxillary buttresses to fix a total of four l-shaped mini plates. Oblique loads of 125 N, directed from palatal to buccal, and a total of 250 N compression loads were applied to the central fossa of the premolar and molar teeth in the maxillary model at a 30° angle relative to the long axis of the teeth. Displacement values at the osteotomy line, Von Mises stresses in the mini plate-screws, and principal stresses in the bone were compared.</p><p><strong>Results: </strong>Examination of stress values in the fixation systems of the models revealed higher stress values in the Cfr-PEEK model compared to the titanium model. However, these stresses did not reach levels that would deform the Cfr-PEEK fixation systems. Stress and displacement values in the bone were lower in the Cfr-PEEK model compared to the titanium model.</p><p><strong>Conclusion: </strong>According to the findings of our study, Cfr-PEEK represents a viable alternative to titanium for mini plate material in Le Fort I osteotomy, offering biomechanical advantages.</p>\",\"PeriodicalId\":56038,\"journal\":{\"name\":\"Journal of Stomatology Oral and Maxillofacial Surgery\",\"volume\":\" \",\"pages\":\"102153\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Stomatology Oral and Maxillofacial Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jormas.2024.102153\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Stomatology Oral and Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jormas.2024.102153","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在探讨60%碳纤维增强聚醚醚酮(Cfr-PEEK)的生物力学特性,该材料具有较高的机械强度,可解决勒堡I型截骨术中使用的钛迷你板的局限性:根据成人的断层扫描图像,使用有限元分析法创建模型。在 Le Fort I 型截骨术后,对模型进行 5 毫米的上颌骨前移。使用了由钛和 60% Cfr-PEEK 制成的迷你板。鼻颌托和颧颌托提供了支撑,共固定了四块 L 形迷你板。从腭侧到颊侧施加 125 牛顿的斜向载荷,并在上颌模型的前磨牙和磨牙中心窝施加总计 250 牛顿的压缩载荷,与牙齿长轴成 30° 角。比较了截骨线处的位移值、微型板状螺钉中的 Von Mises 应力和骨中的主应力:结果:对模型固定系统应力值的检查显示,Cfr-PEEK 模型的应力值高于钛模型。然而,这些应力并未达到导致 Cfr-PEEK 固定系统变形的水平。与钛模型相比,Cfr-PEEK 模型中骨骼的应力和位移值较低:根据我们的研究结果,在 Le Fort I 截骨术中,Cfr-PEEK 是钛迷你钢板材料的可行替代品,具有生物力学优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the biomechanical effects and stability of titanium and carbon fiber-reinforced polyetheretherketone mini plates in Le Fort I advancement osteotomy fixation using finite element analysis.

Aim: This study aimed to investigate the biomechanical properties of 60 % carbon fiber-reinforced polyetheretherketone (Cfr-PEEK), which exhibits high mechanical strength and can address the limitations of titanium mini plates used in Le Fort I osteotomy.

Material and method: Models were created using the FEA method based on tomography images of adult individuals. A 5 mm maxillary advancement was applied to the models following Le Fort I osteotomy. Mini plates made of titanium and 60 % Cfr-PEEK were used. Support was provided by the nasomaxillary and zygomaticomaxillary buttresses to fix a total of four l-shaped mini plates. Oblique loads of 125 N, directed from palatal to buccal, and a total of 250 N compression loads were applied to the central fossa of the premolar and molar teeth in the maxillary model at a 30° angle relative to the long axis of the teeth. Displacement values at the osteotomy line, Von Mises stresses in the mini plate-screws, and principal stresses in the bone were compared.

Results: Examination of stress values in the fixation systems of the models revealed higher stress values in the Cfr-PEEK model compared to the titanium model. However, these stresses did not reach levels that would deform the Cfr-PEEK fixation systems. Stress and displacement values in the bone were lower in the Cfr-PEEK model compared to the titanium model.

Conclusion: According to the findings of our study, Cfr-PEEK represents a viable alternative to titanium for mini plate material in Le Fort I osteotomy, offering biomechanical advantages.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
9.10%
发文量
305
期刊介绍: J Stomatol Oral Maxillofac Surg publishes research papers and techniques - (guest) editorials, original articles, reviews, technical notes, case reports, images, letters to the editor, guidelines - dedicated to enhancing surgical expertise in all fields relevant to oral and maxillofacial surgery: from plastic and reconstructive surgery of the face, oral surgery and medicine, … to dentofacial and maxillofacial orthopedics. Original articles include clinical or laboratory investigations and clinical or equipment reports. Reviews include narrative reviews, systematic reviews and meta-analyses. All manuscripts submitted to the journal are subjected to peer review by international experts, and must: Be written in excellent English, clear and easy to understand, precise and concise; Bring new, interesting, valid information - and improve clinical care or guide future research; Be solely the work of the author(s) stated; Not have been previously published elsewhere and not be under consideration by another journal; Be in accordance with the journal''s Guide for Authors'' instructions: manuscripts that fail to comply with these rules may be returned to the authors without being reviewed. Under no circumstances does the journal guarantee publication before the editorial board makes its final decision. The journal is indexed in the main international databases and is accessible worldwide through the ScienceDirect and ClinicalKey Platforms.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信