Fernando García-Muñoz , Andrés Felipe Cortés-Borray
{"title":"不确定性条件下不平衡配电网络中考虑能源枢纽的多能源载体优化运行","authors":"Fernando García-Muñoz , Andrés Felipe Cortés-Borray","doi":"10.1016/j.segan.2024.101538","DOIUrl":null,"url":null,"abstract":"<div><div>This article presents a two-stage stochastic programming model to address the dispatching scheduling problem in an energy hub, considering an unbalanced active low-voltage (LV) network. A three-phase version of the second-order cone relaxation of DistFlow AC optimal power flow (AC-OPF) is employed to incorporate unbalanced network constraints, while the objective minimizes the Local Energy Community (LEC) operational cost. The model results have been validated using OpenDSS, encompassing energy losses, voltage levels, and active/reactive power. Likewise, a comparative analysis between the three-phase model and the traditional single-phase model, using a modified version of the IEEE European LV Test Feeder as a case study, reveals interesting differences, such that the single-phase model underestimates voltage limits during photovoltaic (PV) system operation and overestimates energy purchased from the main grid, compared with the three-phase model. Similarly, the comparison results reveal that discrepancies between the single and three-phase models intensify as the power injected from PV systems rises. This notably impacts the total energy purchased from the grid, battery operation, and the satisfaction of thermal consumption through electricity. Finally, while the three-phase model offers valuable insights into security levels for voltage and grid energy purchase, its longer computational time makes it more suitable for strategic use rather than daily operational frameworks.</div></div>","PeriodicalId":56142,"journal":{"name":"Sustainable Energy Grids & Networks","volume":"40 ","pages":"Article 101538"},"PeriodicalIF":4.8000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal operation of multi-energy carriers considering energy hubs in unbalanced distribution networks under uncertainty\",\"authors\":\"Fernando García-Muñoz , Andrés Felipe Cortés-Borray\",\"doi\":\"10.1016/j.segan.2024.101538\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This article presents a two-stage stochastic programming model to address the dispatching scheduling problem in an energy hub, considering an unbalanced active low-voltage (LV) network. A three-phase version of the second-order cone relaxation of DistFlow AC optimal power flow (AC-OPF) is employed to incorporate unbalanced network constraints, while the objective minimizes the Local Energy Community (LEC) operational cost. The model results have been validated using OpenDSS, encompassing energy losses, voltage levels, and active/reactive power. Likewise, a comparative analysis between the three-phase model and the traditional single-phase model, using a modified version of the IEEE European LV Test Feeder as a case study, reveals interesting differences, such that the single-phase model underestimates voltage limits during photovoltaic (PV) system operation and overestimates energy purchased from the main grid, compared with the three-phase model. Similarly, the comparison results reveal that discrepancies between the single and three-phase models intensify as the power injected from PV systems rises. This notably impacts the total energy purchased from the grid, battery operation, and the satisfaction of thermal consumption through electricity. Finally, while the three-phase model offers valuable insights into security levels for voltage and grid energy purchase, its longer computational time makes it more suitable for strategic use rather than daily operational frameworks.</div></div>\",\"PeriodicalId\":56142,\"journal\":{\"name\":\"Sustainable Energy Grids & Networks\",\"volume\":\"40 \",\"pages\":\"Article 101538\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sustainable Energy Grids & Networks\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352467724002674\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sustainable Energy Grids & Networks","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352467724002674","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Optimal operation of multi-energy carriers considering energy hubs in unbalanced distribution networks under uncertainty
This article presents a two-stage stochastic programming model to address the dispatching scheduling problem in an energy hub, considering an unbalanced active low-voltage (LV) network. A three-phase version of the second-order cone relaxation of DistFlow AC optimal power flow (AC-OPF) is employed to incorporate unbalanced network constraints, while the objective minimizes the Local Energy Community (LEC) operational cost. The model results have been validated using OpenDSS, encompassing energy losses, voltage levels, and active/reactive power. Likewise, a comparative analysis between the three-phase model and the traditional single-phase model, using a modified version of the IEEE European LV Test Feeder as a case study, reveals interesting differences, such that the single-phase model underestimates voltage limits during photovoltaic (PV) system operation and overestimates energy purchased from the main grid, compared with the three-phase model. Similarly, the comparison results reveal that discrepancies between the single and three-phase models intensify as the power injected from PV systems rises. This notably impacts the total energy purchased from the grid, battery operation, and the satisfaction of thermal consumption through electricity. Finally, while the three-phase model offers valuable insights into security levels for voltage and grid energy purchase, its longer computational time makes it more suitable for strategic use rather than daily operational frameworks.
期刊介绍:
Sustainable Energy, Grids and Networks (SEGAN)is an international peer-reviewed publication for theoretical and applied research dealing with energy, information grids and power networks, including smart grids from super to micro grid scales. SEGAN welcomes papers describing fundamental advances in mathematical, statistical or computational methods with application to power and energy systems, as well as papers on applications, computation and modeling in the areas of electrical and energy systems with coupled information and communication technologies.