图像板对 1-14 MeV 范围内聚变质子的多扫描响应。

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
N Vanderloo, M Cufari, L Russell, T M Johnson, J Vargas, B C Foo, B I Buschmann, S G Dannhoff, A DeVault, T E Evans, J H Kunimune, Y Lawrence, J A Pearcy, B L Reichelt, C W Wink, M Gatu Johnson, R D Petrasso, J A Frenje, C K Li
{"title":"图像板对 1-14 MeV 范围内聚变质子的多扫描响应。","authors":"N Vanderloo, M Cufari, L Russell, T M Johnson, J Vargas, B C Foo, B I Buschmann, S G Dannhoff, A DeVault, T E Evans, J H Kunimune, Y Lawrence, J A Pearcy, B L Reichelt, C W Wink, M Gatu Johnson, R D Petrasso, J A Frenje, C K Li","doi":"10.1063/5.0219547","DOIUrl":null,"url":null,"abstract":"<p><p>Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Image plate multi-scan response to fusion protons in the range of 1-14 MeV.\",\"authors\":\"N Vanderloo, M Cufari, L Russell, T M Johnson, J Vargas, B C Foo, B I Buschmann, S G Dannhoff, A DeVault, T E Evans, J H Kunimune, Y Lawrence, J A Pearcy, B L Reichelt, C W Wink, M Gatu Johnson, R D Petrasso, J A Frenje, C K Li\",\"doi\":\"10.1063/5.0219547\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0219547\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0219547","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

成像板(IP)是一种可快速恢复和重复使用的辐射探测器,通常用于测量激光驱动实验中的质子和 X 射线通量。最近,IP 被用于 OMEGA 激光器上的质子射线照相探测器堆栈,这是一种历史上使用 CR-39 或放射性变色胶片进行的诊断。在这种诊断和其他诊断中使用的 IP 可以不加区分地探测带电粒子、中子和 X 射线。IP 利用光致发光(PSL)材料(通常是荧光粉)检测辐射,其中电子被电离辐射激发至瞬态。由于质子存在布拉格峰,与 20 千伏以下的 X 射线相比,MeV 能量的质子会将能量沉积到 IP 的更深处。利用这一特性可以区分辐射类型。利用麻省理工学院的线性静电离子加速器,将 1.7 至 14 MeV 的单能质子剂量应用于 IP。本文介绍了用不同质子能量对 IPs 进行连续扫描的结果。结果表明,后续扫描之间的 PSL 比率取决于质子能量,能量越高的质子每次扫描的 PSL 比率越低。这一发现与已知的 IPs 绝对灵敏度的能量依赖性不同。该结果可与 X 射线的相关工作进行比较,后者显示了质子和 X 射线之间的差异,为在混合辐射环境中区分质子和 X 射线通量开辟了道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Image plate multi-scan response to fusion protons in the range of 1-14 MeV.

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信