基于超声波的机器人辅助钻孔微创椎弓根螺钉置入术

IF 3.4 Q2 ENGINEERING, BIOMEDICAL
Ruixuan Li;Ayoob Davoodi;Maikel Timmermans;Kaat Van Assche;Orçun Taylan;Lennart Scheys;Matthias Tummers;Gianni Borghesan;Emmanuel Vander Poorten
{"title":"基于超声波的机器人辅助钻孔微创椎弓根螺钉置入术","authors":"Ruixuan Li;Ayoob Davoodi;Maikel Timmermans;Kaat Van Assche;Orçun Taylan;Lennart Scheys;Matthias Tummers;Gianni Borghesan;Emmanuel Vander Poorten","doi":"10.1109/TMRB.2024.3385793","DOIUrl":null,"url":null,"abstract":"Minimally invasive pedicle screw placement (MIPSP) is a widely used treatment for spine diseases. When coupled with intraoperative navigation modalities, robots may help improve surgical outcomes and reduce complications. With such a system, the application of pedicle screws has been expanded from needle insertion to the spine surgery. This paper investigates the possibility and feasibility of robot-assisted MIPSP based on ultrasound (US) guidance. The proposed system is non-radiative and fiducial-free, using purely image information to close the registration loop. Then the system automatically positions the drill tip to a planned screw trajectory and executes the drilling operation. Experiments were conducted on both ex-vivo lamb and human cadaver spines. An entry point accuracy of \n<inline-formula> <tex-math>$2.39\\pm 1.41$ </tex-math></inline-formula>\n mm, and orientation accuracy of \n<inline-formula> <tex-math>$2.82\\pm 1.85^{\\circ }$ </tex-math></inline-formula>\n was found for 24 drilled trajectories on three lamb spines. On the ex-vivo human spine, the position error averaged \n<inline-formula> <tex-math>$3.08\\pm 2.43$ </tex-math></inline-formula>\n mm at the entry point and \n<inline-formula> <tex-math>$4.05\\pm 2.62$ </tex-math></inline-formula>\n mm at the stop point across 16 drilling instances. Moreover, a \n<inline-formula> <tex-math>$87.5\\%$ </tex-math></inline-formula>\n success rate was reported by using Gertzbein-Robbins grade. The experimental results demonstrate the potential for offering a radiation-free alternative. Although restricted to cadaver trials, this work encourages further exploration of this technology to assist surgeons in maximizing performance in clinical practice.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasound-Based Robot-Assisted Drilling for Minimally Invasive Pedicle Screw Placement\",\"authors\":\"Ruixuan Li;Ayoob Davoodi;Maikel Timmermans;Kaat Van Assche;Orçun Taylan;Lennart Scheys;Matthias Tummers;Gianni Borghesan;Emmanuel Vander Poorten\",\"doi\":\"10.1109/TMRB.2024.3385793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Minimally invasive pedicle screw placement (MIPSP) is a widely used treatment for spine diseases. When coupled with intraoperative navigation modalities, robots may help improve surgical outcomes and reduce complications. With such a system, the application of pedicle screws has been expanded from needle insertion to the spine surgery. This paper investigates the possibility and feasibility of robot-assisted MIPSP based on ultrasound (US) guidance. The proposed system is non-radiative and fiducial-free, using purely image information to close the registration loop. Then the system automatically positions the drill tip to a planned screw trajectory and executes the drilling operation. Experiments were conducted on both ex-vivo lamb and human cadaver spines. An entry point accuracy of \\n<inline-formula> <tex-math>$2.39\\\\pm 1.41$ </tex-math></inline-formula>\\n mm, and orientation accuracy of \\n<inline-formula> <tex-math>$2.82\\\\pm 1.85^{\\\\circ }$ </tex-math></inline-formula>\\n was found for 24 drilled trajectories on three lamb spines. On the ex-vivo human spine, the position error averaged \\n<inline-formula> <tex-math>$3.08\\\\pm 2.43$ </tex-math></inline-formula>\\n mm at the entry point and \\n<inline-formula> <tex-math>$4.05\\\\pm 2.62$ </tex-math></inline-formula>\\n mm at the stop point across 16 drilling instances. Moreover, a \\n<inline-formula> <tex-math>$87.5\\\\%$ </tex-math></inline-formula>\\n success rate was reported by using Gertzbein-Robbins grade. The experimental results demonstrate the potential for offering a radiation-free alternative. Although restricted to cadaver trials, this work encourages further exploration of this technology to assist surgeons in maximizing performance in clinical practice.\",\"PeriodicalId\":73318,\"journal\":{\"name\":\"IEEE transactions on medical robotics and bionics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on medical robotics and bionics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10494398/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10494398/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

微创椎弓根螺钉置入术(MIPSP)是一种广泛应用于脊柱疾病的治疗方法。如果配合术中导航模式,机器人可帮助改善手术效果并减少并发症。有了这样的系统,椎弓根螺钉的应用已从插针扩展到脊柱手术。本文研究了基于超声(US)引导的机器人辅助 MIPSP 的可能性和可行性。所提出的系统无辐射、无靶标,纯粹利用图像信息来闭合套准环。然后,系统自动将钻尖定位到计划的螺钉轨迹,并执行钻孔操作。实验在活体羔羊和人体尸体脊柱上进行。在三根羔羊脊柱上的 24 个钻孔轨迹中,发现切入点精度为 2.39pm 1.41$ mm,定位精度为 2.82pm 1.85^{\circ }$。在活体人体脊柱上,16 次钻孔中,进入点的位置误差平均为 $3.08\pm 2.43$ mm,停止点的位置误差平均为 $4.05\pm 2.62$ mm。此外,使用 Gertzbein-Robbins 等级的成功率为 87.5%。实验结果证明了提供无辐射替代方法的潜力。虽然仅限于尸体试验,但这项工作鼓励进一步探索这项技术,以帮助外科医生在临床实践中最大限度地提高性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ultrasound-Based Robot-Assisted Drilling for Minimally Invasive Pedicle Screw Placement
Minimally invasive pedicle screw placement (MIPSP) is a widely used treatment for spine diseases. When coupled with intraoperative navigation modalities, robots may help improve surgical outcomes and reduce complications. With such a system, the application of pedicle screws has been expanded from needle insertion to the spine surgery. This paper investigates the possibility and feasibility of robot-assisted MIPSP based on ultrasound (US) guidance. The proposed system is non-radiative and fiducial-free, using purely image information to close the registration loop. Then the system automatically positions the drill tip to a planned screw trajectory and executes the drilling operation. Experiments were conducted on both ex-vivo lamb and human cadaver spines. An entry point accuracy of $2.39\pm 1.41$ mm, and orientation accuracy of $2.82\pm 1.85^{\circ }$ was found for 24 drilled trajectories on three lamb spines. On the ex-vivo human spine, the position error averaged $3.08\pm 2.43$ mm at the entry point and $4.05\pm 2.62$ mm at the stop point across 16 drilling instances. Moreover, a $87.5\%$ success rate was reported by using Gertzbein-Robbins grade. The experimental results demonstrate the potential for offering a radiation-free alternative. Although restricted to cadaver trials, this work encourages further exploration of this technology to assist surgeons in maximizing performance in clinical practice.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信