Young Hyun Kim, Joshua Lee, Sarah M Yi, Meng C Lin, Clayton J Radke
{"title":"局部蒸发冷却解释了观察到的眼表温度模式。","authors":"Young Hyun Kim, Joshua Lee, Sarah M Yi, Meng C Lin, Clayton J Radke","doi":"10.1167/iovs.65.10.15","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We determined interblink corneal surface-temperature decline and tear-film evaporation rates of localized tear breakup cold regions (LCRs) and localized tear unbroken warm regions (LWRs) of the corneal surface, as well as that of the overall average corneal surface.</p><p><strong>Methods: </strong>Each subject underwent 4 inter-day visits where the interblink corneal surface-temperature history of the right eye was measured using a FLIR A655sc infrared thermographer. Corneal surface temperature history was analyzed to determine the overall, LCR, and LWR temperature-decline rates. Evaporation rates of LCR and LWR regions were determined from the measured LCR and LWR temperature data using the physical model of Dursch et al.</p><p><strong>Results: </strong>Twenty subjects completed the study. Mean (SD) difference of LCR temperature-decline rate was -0.08 (0.07)°C/s faster than LWR (P < 0.0001). Similarly, evaporation rates of LCR and LWR were statistically different (P < 0.0001). At ambient temperature, mean LCR and LWR evaporation rates were 76% and 27% of pure water evaporation flux, respectively. There was no statistically significant difference between the inter-day measured temperature-decline rates and the interblink starting temperature.</p><p><strong>Conclusions: </strong>Significant differences in corneal temperature-decline rate and evaporation rate between LCR and LWR were quantified using infrared thermography. In agreement with literature, LCRs and LWRs correlate directly with fluorescein break-up areas and unbroken tear areas, respectively. Because lipid-evaporation protection is diminished in breakup areas, higher local evaporation rates and faster local cooling rates occur in LCRs relative to LWRs. Our results confirm this phenomenon clinically for the first time.</p>","PeriodicalId":14620,"journal":{"name":"Investigative ophthalmology & visual science","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11314627/pdf/","citationCount":"0","resultStr":"{\"title\":\"Localized Evaporative Cooling Explains Observed Ocular Surface-Temperature Patterns.\",\"authors\":\"Young Hyun Kim, Joshua Lee, Sarah M Yi, Meng C Lin, Clayton J Radke\",\"doi\":\"10.1167/iovs.65.10.15\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We determined interblink corneal surface-temperature decline and tear-film evaporation rates of localized tear breakup cold regions (LCRs) and localized tear unbroken warm regions (LWRs) of the corneal surface, as well as that of the overall average corneal surface.</p><p><strong>Methods: </strong>Each subject underwent 4 inter-day visits where the interblink corneal surface-temperature history of the right eye was measured using a FLIR A655sc infrared thermographer. Corneal surface temperature history was analyzed to determine the overall, LCR, and LWR temperature-decline rates. Evaporation rates of LCR and LWR regions were determined from the measured LCR and LWR temperature data using the physical model of Dursch et al.</p><p><strong>Results: </strong>Twenty subjects completed the study. Mean (SD) difference of LCR temperature-decline rate was -0.08 (0.07)°C/s faster than LWR (P < 0.0001). Similarly, evaporation rates of LCR and LWR were statistically different (P < 0.0001). At ambient temperature, mean LCR and LWR evaporation rates were 76% and 27% of pure water evaporation flux, respectively. There was no statistically significant difference between the inter-day measured temperature-decline rates and the interblink starting temperature.</p><p><strong>Conclusions: </strong>Significant differences in corneal temperature-decline rate and evaporation rate between LCR and LWR were quantified using infrared thermography. In agreement with literature, LCRs and LWRs correlate directly with fluorescein break-up areas and unbroken tear areas, respectively. Because lipid-evaporation protection is diminished in breakup areas, higher local evaporation rates and faster local cooling rates occur in LCRs relative to LWRs. Our results confirm this phenomenon clinically for the first time.</p>\",\"PeriodicalId\":14620,\"journal\":{\"name\":\"Investigative ophthalmology & visual science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11314627/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Investigative ophthalmology & visual science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1167/iovs.65.10.15\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative ophthalmology & visual science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1167/iovs.65.10.15","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Purpose: We determined interblink corneal surface-temperature decline and tear-film evaporation rates of localized tear breakup cold regions (LCRs) and localized tear unbroken warm regions (LWRs) of the corneal surface, as well as that of the overall average corneal surface.
Methods: Each subject underwent 4 inter-day visits where the interblink corneal surface-temperature history of the right eye was measured using a FLIR A655sc infrared thermographer. Corneal surface temperature history was analyzed to determine the overall, LCR, and LWR temperature-decline rates. Evaporation rates of LCR and LWR regions were determined from the measured LCR and LWR temperature data using the physical model of Dursch et al.
Results: Twenty subjects completed the study. Mean (SD) difference of LCR temperature-decline rate was -0.08 (0.07)°C/s faster than LWR (P < 0.0001). Similarly, evaporation rates of LCR and LWR were statistically different (P < 0.0001). At ambient temperature, mean LCR and LWR evaporation rates were 76% and 27% of pure water evaporation flux, respectively. There was no statistically significant difference between the inter-day measured temperature-decline rates and the interblink starting temperature.
Conclusions: Significant differences in corneal temperature-decline rate and evaporation rate between LCR and LWR were quantified using infrared thermography. In agreement with literature, LCRs and LWRs correlate directly with fluorescein break-up areas and unbroken tear areas, respectively. Because lipid-evaporation protection is diminished in breakup areas, higher local evaporation rates and faster local cooling rates occur in LCRs relative to LWRs. Our results confirm this phenomenon clinically for the first time.
期刊介绍:
Investigative Ophthalmology & Visual Science (IOVS), published as ready online, is a peer-reviewed academic journal of the Association for Research in Vision and Ophthalmology (ARVO). IOVS features original research, mostly pertaining to clinical and laboratory ophthalmology and vision research in general.