{"title":"机器人 CT 中异步旋转的无参照校准方法。","authors":"Xuan Zhou, Yuedong Liu, Cunfeng Wei, Qiong Xu","doi":"10.3233/XST-240023","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Geometry calibration for robotic CT system is necessary for obtaining acceptable images under the asynchrony of two manipulators.</p><p><strong>Objective: </strong>We aim to evaluate the impact of different types of asynchrony on images and propose a reference-free calibration method based on a simplified geometry model.</p><p><strong>Methods: </strong>We evaluate the impact of different types of asynchrony on images and propose a novel calibration method focused on asynchronous rotation of robotic CT. The proposed method is initialized with reconstructions under default uncalibrated geometry and uses grid sampling of estimated geometry to determine the direction of optimization. Difference between the re-projections of sampling points and the original projection is used to guide the optimization direction. Images and estimated geometry are optimized alternatively in an iteration, and it stops when the difference of residual projections is close enough, or when the maximum iteration number is reached.</p><p><strong>Results: </strong>In our simulation experiments, proposed method shows better performance, with the PSNR increasing by 2%, and the SSIM increasing by 13.6% after calibration. The experiments reveal fewer artifacts and higher image quality.</p><p><strong>Conclusion: </strong>We find that asynchronous rotation has a more significant impact on reconstruction, and the proposed method offers a feasible solution for correcting asynchronous rotation.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reference-free calibration method for asynchronous rotation in robotic CT.\",\"authors\":\"Xuan Zhou, Yuedong Liu, Cunfeng Wei, Qiong Xu\",\"doi\":\"10.3233/XST-240023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Geometry calibration for robotic CT system is necessary for obtaining acceptable images under the asynchrony of two manipulators.</p><p><strong>Objective: </strong>We aim to evaluate the impact of different types of asynchrony on images and propose a reference-free calibration method based on a simplified geometry model.</p><p><strong>Methods: </strong>We evaluate the impact of different types of asynchrony on images and propose a novel calibration method focused on asynchronous rotation of robotic CT. The proposed method is initialized with reconstructions under default uncalibrated geometry and uses grid sampling of estimated geometry to determine the direction of optimization. Difference between the re-projections of sampling points and the original projection is used to guide the optimization direction. Images and estimated geometry are optimized alternatively in an iteration, and it stops when the difference of residual projections is close enough, or when the maximum iteration number is reached.</p><p><strong>Results: </strong>In our simulation experiments, proposed method shows better performance, with the PSNR increasing by 2%, and the SSIM increasing by 13.6% after calibration. The experiments reveal fewer artifacts and higher image quality.</p><p><strong>Conclusion: </strong>We find that asynchronous rotation has a more significant impact on reconstruction, and the proposed method offers a feasible solution for correcting asynchronous rotation.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/XST-240023\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/XST-240023","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Reference-free calibration method for asynchronous rotation in robotic CT.
Background: Geometry calibration for robotic CT system is necessary for obtaining acceptable images under the asynchrony of two manipulators.
Objective: We aim to evaluate the impact of different types of asynchrony on images and propose a reference-free calibration method based on a simplified geometry model.
Methods: We evaluate the impact of different types of asynchrony on images and propose a novel calibration method focused on asynchronous rotation of robotic CT. The proposed method is initialized with reconstructions under default uncalibrated geometry and uses grid sampling of estimated geometry to determine the direction of optimization. Difference between the re-projections of sampling points and the original projection is used to guide the optimization direction. Images and estimated geometry are optimized alternatively in an iteration, and it stops when the difference of residual projections is close enough, or when the maximum iteration number is reached.
Results: In our simulation experiments, proposed method shows better performance, with the PSNR increasing by 2%, and the SSIM increasing by 13.6% after calibration. The experiments reveal fewer artifacts and higher image quality.
Conclusion: We find that asynchronous rotation has a more significant impact on reconstruction, and the proposed method offers a feasible solution for correcting asynchronous rotation.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.