PED治疗颈内动脉未破裂动脉瘤的疗效:PED-Flex 和 PED-Shield 的比较。

IF 2.4 4区 医学 Q2 CLINICAL NEUROLOGY
Neurologia medico-chirurgica Pub Date : 2024-08-15 Epub Date: 2024-06-19 DOI:10.2176/jns-nmc.2024-0034
Saki Kawamoto, Tomohiko Ozaki, Katsunori Asai, Tomoki Kidani, Nobuyuki Izutsu, Shin Nakajima, Yonehiro Kanemura, Naoki Nishizawa, Koji Kobayashi, Yosuke Fujimi, Toshiyuki Fujinaka
{"title":"PED治疗颈内动脉未破裂动脉瘤的疗效:PED-Flex 和 PED-Shield 的比较。","authors":"Saki Kawamoto, Tomohiko Ozaki, Katsunori Asai, Tomoki Kidani, Nobuyuki Izutsu, Shin Nakajima, Yonehiro Kanemura, Naoki Nishizawa, Koji Kobayashi, Yosuke Fujimi, Toshiyuki Fujinaka","doi":"10.2176/jns-nmc.2024-0034","DOIUrl":null,"url":null,"abstract":"<p><p>There is a lack of data regarding the safety and effectiveness of implanting the Pipeline Embolization Device with Shield technology (PED-Shield) compared with the previous generation of Pipeline (PED-Flex). This retrospective single-center study aimed to compare treatment outcomes between the PED-Shield and PED-Flex for treating unruptured internal carotid artery aneurysms. The PED-Flex was used in 62 procedures (67 aneurysms, 59 patients) and the PED-Shield in 53 procedures (59 aneurysms, 58 patients). The mean aneurysm diameter was significantly lower in the PED-Shield group than in the PED-Flex group (11.9 ± 7.0 mm vs. 15.2 ± 6.9 mm, p < 0.001). At the 12-month follow-up, the complete angiographic occlusion rate was 72.1% and 72.3% in the PED-Flex and PED-Shield groups, respectively (p = 0.9808). Limited to aneurysms larger than 10 mm, 70.6% and 68.0%, respectively (p = 0.8175). The incidence of more than three high signal intensity areas on diffusion-weighted imaging after treatment was significantly lower in the PED-Shield group than in the PED-Flex group (27.7% vs. 67.7%; p < 0.001). Limited to aneurysms larger than 10 mm, 41.1% and 69.6%, respectively (p < 0.0117). Symptomatic ischemic complications occurred within 30 days of four PED-Flex procedures (6.5%) and one PED-Shield procedure (2.0%) (p = 0.2315). Limited to aneurysms larger than 10 mm, 1.8% and 3.2%, respectively (p = 0.6677). The incidence of mRS score worsening at 6 months was 3.2% and 1.9% in the PED-Flex and PED-Shield groups, respectively (p = 0.6534). The PED-Shield can achieve outcomes equivalent to or better than the PED-Flex. Further large-scale studies are warranted to confirm our findings.</p>","PeriodicalId":19225,"journal":{"name":"Neurologia medico-chirurgica","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374462/pdf/","citationCount":"0","resultStr":"{\"title\":\"Treatment Outcomes of PED for Unruptured Aneurysms of Internal Carotid Artery: Comparison of PED-Flex and PED-Shield.\",\"authors\":\"Saki Kawamoto, Tomohiko Ozaki, Katsunori Asai, Tomoki Kidani, Nobuyuki Izutsu, Shin Nakajima, Yonehiro Kanemura, Naoki Nishizawa, Koji Kobayashi, Yosuke Fujimi, Toshiyuki Fujinaka\",\"doi\":\"10.2176/jns-nmc.2024-0034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There is a lack of data regarding the safety and effectiveness of implanting the Pipeline Embolization Device with Shield technology (PED-Shield) compared with the previous generation of Pipeline (PED-Flex). This retrospective single-center study aimed to compare treatment outcomes between the PED-Shield and PED-Flex for treating unruptured internal carotid artery aneurysms. The PED-Flex was used in 62 procedures (67 aneurysms, 59 patients) and the PED-Shield in 53 procedures (59 aneurysms, 58 patients). The mean aneurysm diameter was significantly lower in the PED-Shield group than in the PED-Flex group (11.9 ± 7.0 mm vs. 15.2 ± 6.9 mm, p < 0.001). At the 12-month follow-up, the complete angiographic occlusion rate was 72.1% and 72.3% in the PED-Flex and PED-Shield groups, respectively (p = 0.9808). Limited to aneurysms larger than 10 mm, 70.6% and 68.0%, respectively (p = 0.8175). The incidence of more than three high signal intensity areas on diffusion-weighted imaging after treatment was significantly lower in the PED-Shield group than in the PED-Flex group (27.7% vs. 67.7%; p < 0.001). Limited to aneurysms larger than 10 mm, 41.1% and 69.6%, respectively (p < 0.0117). Symptomatic ischemic complications occurred within 30 days of four PED-Flex procedures (6.5%) and one PED-Shield procedure (2.0%) (p = 0.2315). Limited to aneurysms larger than 10 mm, 1.8% and 3.2%, respectively (p = 0.6677). The incidence of mRS score worsening at 6 months was 3.2% and 1.9% in the PED-Flex and PED-Shield groups, respectively (p = 0.6534). The PED-Shield can achieve outcomes equivalent to or better than the PED-Flex. Further large-scale studies are warranted to confirm our findings.</p>\",\"PeriodicalId\":19225,\"journal\":{\"name\":\"Neurologia medico-chirurgica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374462/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurologia medico-chirurgica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2176/jns-nmc.2024-0034\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurologia medico-chirurgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2176/jns-nmc.2024-0034","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

与上一代 Pipeline(PED-Flex)相比,目前还缺乏有关植入带屏蔽技术的 Pipeline 栓塞设备(PED-Shield)安全性和有效性的数据。这项回顾性单中心研究旨在比较 PED-Shield 和 PED-Flex 治疗未破裂颈内动脉瘤的疗效。在 62 例手术(67 个动脉瘤,59 名患者)中使用了 PED-Flex,在 53 例手术(59 个动脉瘤,58 名患者)中使用了 PED-Shield。PED-Shield 组的平均动脉瘤直径明显低于 PED-Flex 组(11.9 ± 7.0 mm 对 15.2 ± 6.9 mm,p < 0.001)。在 12 个月的随访中,PED-Flex 组和 PED-Shield 组的血管造影完全闭塞率分别为 72.1% 和 72.3%(p = 0.9808)。仅限于大于 10 毫米的动脉瘤的完全闭塞率分别为 70.6% 和 68.0%(p = 0.8175)。治疗后弥散加权成像出现三个以上高信号强度区域的发生率,PED-Shield 组明显低于 PED-Flex 组(27.7% 对 67.7%;p < 0.001)。限于大于 10 毫米的动脉瘤,PED-Shield 组和 PED-Flex 组的比例分别为 41.1% 和 69.6%(p < 0.0117)。4例PED-Flex手术(6.5%)和1例PED-Shield手术(2.0%)在30天内出现症状性缺血并发症(p = 0.2315)。仅限于大于 10 毫米的动脉瘤,分别为 1.8%和 3.2%(p = 0.6677)。PED-Flex 组和 PED-Shield 组 6 个月时 mRS 评分恶化的发生率分别为 3.2% 和 1.9% (p = 0.6534)。PED-Shield 的疗效等同于或优于 PED-Flex。为了证实我们的研究结果,有必要进行更大规模的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Treatment Outcomes of PED for Unruptured Aneurysms of Internal Carotid Artery: Comparison of PED-Flex and PED-Shield.

There is a lack of data regarding the safety and effectiveness of implanting the Pipeline Embolization Device with Shield technology (PED-Shield) compared with the previous generation of Pipeline (PED-Flex). This retrospective single-center study aimed to compare treatment outcomes between the PED-Shield and PED-Flex for treating unruptured internal carotid artery aneurysms. The PED-Flex was used in 62 procedures (67 aneurysms, 59 patients) and the PED-Shield in 53 procedures (59 aneurysms, 58 patients). The mean aneurysm diameter was significantly lower in the PED-Shield group than in the PED-Flex group (11.9 ± 7.0 mm vs. 15.2 ± 6.9 mm, p < 0.001). At the 12-month follow-up, the complete angiographic occlusion rate was 72.1% and 72.3% in the PED-Flex and PED-Shield groups, respectively (p = 0.9808). Limited to aneurysms larger than 10 mm, 70.6% and 68.0%, respectively (p = 0.8175). The incidence of more than three high signal intensity areas on diffusion-weighted imaging after treatment was significantly lower in the PED-Shield group than in the PED-Flex group (27.7% vs. 67.7%; p < 0.001). Limited to aneurysms larger than 10 mm, 41.1% and 69.6%, respectively (p < 0.0117). Symptomatic ischemic complications occurred within 30 days of four PED-Flex procedures (6.5%) and one PED-Shield procedure (2.0%) (p = 0.2315). Limited to aneurysms larger than 10 mm, 1.8% and 3.2%, respectively (p = 0.6677). The incidence of mRS score worsening at 6 months was 3.2% and 1.9% in the PED-Flex and PED-Shield groups, respectively (p = 0.6534). The PED-Shield can achieve outcomes equivalent to or better than the PED-Flex. Further large-scale studies are warranted to confirm our findings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Neurologia medico-chirurgica
Neurologia medico-chirurgica 医学-临床神经学
CiteScore
3.70
自引率
10.50%
发文量
63
审稿时长
3-8 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信