一项系统性综述,比较了充气阴茎假体翻修的不同方法:部分组件交换、完全组件交换或贮藏器 "引流和保留"。

IF 3.6 2区 医学 Q1 UROLOGY & NEPHROLOGY
Adnan El-Achkar, Kareim Khalafalla, Tuan Thanh Nguyen, Run Wang
{"title":"一项系统性综述,比较了充气阴茎假体翻修的不同方法:部分组件交换、完全组件交换或贮藏器 \"引流和保留\"。","authors":"Adnan El-Achkar, Kareim Khalafalla, Tuan Thanh Nguyen, Run Wang","doi":"10.1093/sxmrev/qeae035","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In cases of a noninfected malfunctioning inflatable penile prosthesis (IPP) device, surgeons often opt to exchange all of the device rather than the defective component for fear of an increased infection rate and future mechanical dysfunction.</p><p><strong>Objectives: </strong>To assess whether partial-component exchange of an IPP device has comparable outcomes to complete explant and replacement of an IPP device with or without a retained reservoir.</p><p><strong>Methods: </strong>A systematic review was conducted following the PRISMA 2020 and AMSTAR guidelines. Searches were performed on MEDLINE (Ovid), PubMed, and the Cochrane Library from inception to June 2023, identifying studies reporting outcomes and complications of revision surgery for noninfected malfunctioning IPP devices. Three groups were compared: those undergoing single- or 2-component exchange, those with complete explantation and replacement, and those with replacement of all components while retaining the primary reservoir.</p><p><strong>Results: </strong>Analysis included 11 articles comprising 12 202 patients with complete device replacement, 234 with partial device exchange, and 151 with retained reservoirs following revision. Mean ages ranged from 62 to 68 years, with median follow-up times between 3 and 84 months. Partial-component exchange showed a higher infection rate (6.3%) as compared with complete replacement (2.7%) and reservoir retention (3.9%). Similarly, partial exchange had a higher complication rate (23.9%) when compared with complete replacement (11.3%) and reservoir retention (19.6%). Mechanical failure rates for partial exchange were similar across the 3 groups (10%, 2.8%, and 5.8%, respectively).</p><p><strong>Conclusion: </strong>Partial-component exchange during IPP revision is associated with higher infection and perioperative complication rates but comparable rates of mechanical failure as compared with complete-component replacement, with or without retaining the original reservoir.</p>","PeriodicalId":21813,"journal":{"name":"Sexual medicine reviews","volume":" ","pages":"519-527"},"PeriodicalIF":3.6000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A systematic review comparing different approaches for inflatable penile prosthesis revision: partial-component exchange, complete-component exchange, or reservoir \\\"drain and retain\\\".\",\"authors\":\"Adnan El-Achkar, Kareim Khalafalla, Tuan Thanh Nguyen, Run Wang\",\"doi\":\"10.1093/sxmrev/qeae035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>In cases of a noninfected malfunctioning inflatable penile prosthesis (IPP) device, surgeons often opt to exchange all of the device rather than the defective component for fear of an increased infection rate and future mechanical dysfunction.</p><p><strong>Objectives: </strong>To assess whether partial-component exchange of an IPP device has comparable outcomes to complete explant and replacement of an IPP device with or without a retained reservoir.</p><p><strong>Methods: </strong>A systematic review was conducted following the PRISMA 2020 and AMSTAR guidelines. Searches were performed on MEDLINE (Ovid), PubMed, and the Cochrane Library from inception to June 2023, identifying studies reporting outcomes and complications of revision surgery for noninfected malfunctioning IPP devices. Three groups were compared: those undergoing single- or 2-component exchange, those with complete explantation and replacement, and those with replacement of all components while retaining the primary reservoir.</p><p><strong>Results: </strong>Analysis included 11 articles comprising 12 202 patients with complete device replacement, 234 with partial device exchange, and 151 with retained reservoirs following revision. Mean ages ranged from 62 to 68 years, with median follow-up times between 3 and 84 months. Partial-component exchange showed a higher infection rate (6.3%) as compared with complete replacement (2.7%) and reservoir retention (3.9%). Similarly, partial exchange had a higher complication rate (23.9%) when compared with complete replacement (11.3%) and reservoir retention (19.6%). Mechanical failure rates for partial exchange were similar across the 3 groups (10%, 2.8%, and 5.8%, respectively).</p><p><strong>Conclusion: </strong>Partial-component exchange during IPP revision is associated with higher infection and perioperative complication rates but comparable rates of mechanical failure as compared with complete-component replacement, with or without retaining the original reservoir.</p>\",\"PeriodicalId\":21813,\"journal\":{\"name\":\"Sexual medicine reviews\",\"volume\":\" \",\"pages\":\"519-527\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sexual medicine reviews\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/sxmrev/qeae035\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sexual medicine reviews","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/sxmrev/qeae035","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

简介:在充气阴茎假体(IPP)装置未感染故障的情况下,外科医生通常会选择更换全部装置,而不是有缺陷的组件,因为他们担心感染率会增加,将来会出现机械功能障碍:目的:评估更换IPP装置的部分组件与完全切除和更换IPP装置(带或不带保留的贮存器)的结果是否具有可比性:方法:按照 PRISMA 2020 和 AMSTAR 指南进行了系统性综述。从开始到 2023 年 6 月,在 MEDLINE (Ovid)、PubMed 和 Cochrane 图书馆进行了检索,确定了报告未感染故障 IPP 装置翻修手术结果和并发症的研究。对三组患者进行了比较:接受单组件或双组件交换手术的患者、完全切除并更换组件的患者,以及更换所有组件但保留主要储液器的患者:结果:分析包括11篇文章,其中12 202名患者进行了完全装置置换,234名患者进行了部分装置置换,151名患者在翻修后保留了储液器。平均年龄为 62 至 68 岁,中位随访时间为 3 至 84 个月。与完全置换(2.7%)和储液器保留(3.9%)相比,部分组件置换的感染率更高(6.3%)。同样,与完全置换(11.3%)和贮水池保留(19.6%)相比,部分置换的并发症发生率(23.9%)也更高。三组中部分置换的机械失败率相似(分别为10%、2.8%和5.8%):结论:在 IPP 翻修术中进行部分组件置换与较高的感染率和围手术期并发症发生率有关,但机械故障发生率与进行或不进行完整组件置换(保留或不保留原储水槽)的发生率相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A systematic review comparing different approaches for inflatable penile prosthesis revision: partial-component exchange, complete-component exchange, or reservoir "drain and retain".

Introduction: In cases of a noninfected malfunctioning inflatable penile prosthesis (IPP) device, surgeons often opt to exchange all of the device rather than the defective component for fear of an increased infection rate and future mechanical dysfunction.

Objectives: To assess whether partial-component exchange of an IPP device has comparable outcomes to complete explant and replacement of an IPP device with or without a retained reservoir.

Methods: A systematic review was conducted following the PRISMA 2020 and AMSTAR guidelines. Searches were performed on MEDLINE (Ovid), PubMed, and the Cochrane Library from inception to June 2023, identifying studies reporting outcomes and complications of revision surgery for noninfected malfunctioning IPP devices. Three groups were compared: those undergoing single- or 2-component exchange, those with complete explantation and replacement, and those with replacement of all components while retaining the primary reservoir.

Results: Analysis included 11 articles comprising 12 202 patients with complete device replacement, 234 with partial device exchange, and 151 with retained reservoirs following revision. Mean ages ranged from 62 to 68 years, with median follow-up times between 3 and 84 months. Partial-component exchange showed a higher infection rate (6.3%) as compared with complete replacement (2.7%) and reservoir retention (3.9%). Similarly, partial exchange had a higher complication rate (23.9%) when compared with complete replacement (11.3%) and reservoir retention (19.6%). Mechanical failure rates for partial exchange were similar across the 3 groups (10%, 2.8%, and 5.8%, respectively).

Conclusion: Partial-component exchange during IPP revision is associated with higher infection and perioperative complication rates but comparable rates of mechanical failure as compared with complete-component replacement, with or without retaining the original reservoir.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sexual medicine reviews
Sexual medicine reviews UROLOGY & NEPHROLOGY-
CiteScore
7.60
自引率
8.30%
发文量
5
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信