开发用于催化气体反应操作分析的高压电子显微镜-气相色谱仪-四极杆质谱仪集成系统。

Longshu Tang, Tetsuo Higuchi, Shigeo Arai, Hiromochi Tanaka, Shunsuke Muto
{"title":"开发用于催化气体反应操作分析的高压电子显微镜-气相色谱仪-四极杆质谱仪集成系统。","authors":"Longshu Tang, Tetsuo Higuchi, Shigeo Arai, Hiromochi Tanaka, Shunsuke Muto","doi":"10.1093/jmicro/dfae010","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes the development of a gas chromatography-quadrupole mass spectrometry system attached to a differential-pumping-type environmental cell of the reaction science high-voltage electron microscopy instrument at Nagoya University to distinguish unambiguously between different gas species with the same mass-to-charge ratio. Several model experiments were used to verify the efficacy of the newly proposed system, confirming its ability to analyse the atomic-level structural changes during heterogeneous catalysts and the associated gas-reaction kinetics simultaneously, providing new insights into operando measurements in the field of environmental transmission electron microscopy. Graphical Abstract.</p>","PeriodicalId":74193,"journal":{"name":"Microscopy (Oxford, England)","volume":" ","pages":"358-366"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11288188/pdf/","citationCount":"0","resultStr":"{\"title\":\"Development of an integrated high-voltage electron microscope-gas chromatograph-quadrupole mass spectrometer system for the operando analysis of catalytic gas reactions.\",\"authors\":\"Longshu Tang, Tetsuo Higuchi, Shigeo Arai, Hiromochi Tanaka, Shunsuke Muto\",\"doi\":\"10.1093/jmicro/dfae010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper describes the development of a gas chromatography-quadrupole mass spectrometry system attached to a differential-pumping-type environmental cell of the reaction science high-voltage electron microscopy instrument at Nagoya University to distinguish unambiguously between different gas species with the same mass-to-charge ratio. Several model experiments were used to verify the efficacy of the newly proposed system, confirming its ability to analyse the atomic-level structural changes during heterogeneous catalysts and the associated gas-reaction kinetics simultaneously, providing new insights into operando measurements in the field of environmental transmission electron microscopy. Graphical Abstract.</p>\",\"PeriodicalId\":74193,\"journal\":{\"name\":\"Microscopy (Oxford, England)\",\"volume\":\" \",\"pages\":\"358-366\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11288188/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microscopy (Oxford, England)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jmicro/dfae010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy (Oxford, England)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jmicro/dfae010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了与名古屋大学反应科学高压电子显微镜仪器的差分泵式环境池相连接的气相色谱-四极杆质谱系统的开发情况,该系统能够明确区分具有相同质量电荷比的不同气体种类。通过几个模型实验验证了新系统的功效,证实它能够同时分析异相催化剂过程中的原子级结构变化和相关的气体反应动力学,为环境透射电子显微镜领域的操作测量提供了新的见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of an integrated high-voltage electron microscope-gas chromatograph-quadrupole mass spectrometer system for the operando analysis of catalytic gas reactions.

This paper describes the development of a gas chromatography-quadrupole mass spectrometry system attached to a differential-pumping-type environmental cell of the reaction science high-voltage electron microscopy instrument at Nagoya University to distinguish unambiguously between different gas species with the same mass-to-charge ratio. Several model experiments were used to verify the efficacy of the newly proposed system, confirming its ability to analyse the atomic-level structural changes during heterogeneous catalysts and the associated gas-reaction kinetics simultaneously, providing new insights into operando measurements in the field of environmental transmission electron microscopy. Graphical Abstract.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信