一种利用双平面多能x线片将骨材料属性分配到综合患者特定骨盆有限元模型的新方法。

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Ningxin Qiao, Isabelle Villemure, Carl-Eric Aubin
{"title":"一种利用双平面多能x线片将骨材料属性分配到综合患者特定骨盆有限元模型的新方法。","authors":"Ningxin Qiao, Isabelle Villemure, Carl-Eric Aubin","doi":"10.1080/10255842.2023.2280764","DOIUrl":null,"url":null,"abstract":"<p><p>The increasing prevalence of adult spinal deformity requires long spino-pelvic instrumentation, but pelvic fixation faces challenges due to distal forces and reduced bone quality. Bi-planar multi-energy X-rays (BMEX) were used to develop a patient-specific finite element model (FEM) for evaluating pelvic fixation. Calibration involved 10 patients, and an 81-year-old female test case was used for FEM customization and pullout simulation validation. Calibration yielded a root mean square error of 74.7 mg/cm<sup>3</sup> for HU. The simulation accurately replicated the experimental pullout test with a force of 565 N, highlighting the method's potential for optimizing biomechanical performance for pelvic fixation.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":" ","pages":"2377-2388"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel method for assigning bone material properties to a comprehensive patient-specific pelvic finite element model using biplanar multi-energy radiographs.\",\"authors\":\"Ningxin Qiao, Isabelle Villemure, Carl-Eric Aubin\",\"doi\":\"10.1080/10255842.2023.2280764\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The increasing prevalence of adult spinal deformity requires long spino-pelvic instrumentation, but pelvic fixation faces challenges due to distal forces and reduced bone quality. Bi-planar multi-energy X-rays (BMEX) were used to develop a patient-specific finite element model (FEM) for evaluating pelvic fixation. Calibration involved 10 patients, and an 81-year-old female test case was used for FEM customization and pullout simulation validation. Calibration yielded a root mean square error of 74.7 mg/cm<sup>3</sup> for HU. The simulation accurately replicated the experimental pullout test with a force of 565 N, highlighting the method's potential for optimizing biomechanical performance for pelvic fixation.</p>\",\"PeriodicalId\":50640,\"journal\":{\"name\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"volume\":\" \",\"pages\":\"2377-2388\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10255842.2023.2280764\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2023.2280764","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

摘要

越来越多的成人脊柱畸形需要长时间的脊柱-骨盆内固定,但由于远端受力和骨质量降低,骨盆固定面临挑战。使用双平面多能x射线(BMEX)建立患者特异性有限元模型(FEM)来评估骨盆固定。校准涉及10例患者,并使用一名81岁的女性测试例进行FEM定制和拉拔模拟验证。校准结果显示,HU的均方根误差为74.7 mg/cm3。模拟准确地复制了565 N力的实验拔出试验,突出了该方法在优化骨盆固定生物力学性能方面的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel method for assigning bone material properties to a comprehensive patient-specific pelvic finite element model using biplanar multi-energy radiographs.

The increasing prevalence of adult spinal deformity requires long spino-pelvic instrumentation, but pelvic fixation faces challenges due to distal forces and reduced bone quality. Bi-planar multi-energy X-rays (BMEX) were used to develop a patient-specific finite element model (FEM) for evaluating pelvic fixation. Calibration involved 10 patients, and an 81-year-old female test case was used for FEM customization and pullout simulation validation. Calibration yielded a root mean square error of 74.7 mg/cm3 for HU. The simulation accurately replicated the experimental pullout test with a force of 565 N, highlighting the method's potential for optimizing biomechanical performance for pelvic fixation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信