{"title":"评估经血浆处理溶液生物活性的 FOX 和 Griess 方法的特点","authors":"Victoria V. Gudkova,&nbsp;Darya A. Razvolyaeva,&nbsp;Valentin D. Borzosekov,&nbsp;Evgeny M. Konchekov","doi":"10.1007/s11090-023-10418-8","DOIUrl":null,"url":null,"abstract":"<div><p>The paper reveals the problem of measuring reactive oxygen (ROS) and nitrogen (RNS) species’ concentrations in plasma treated water Milli-Q. We investigate the features of the FOX method for hydrogen peroxide concentration measurement and the Griess method for nitrite ions concentration spectrophotometric measurement using two different ways of an aqueous solution treatment. In the first case, the electrode (non-conducting high-temperature ceramics) was above the aqueous solution and the discharge was in the gas phase. In the second case, the electrodes were fixed around the perimeter inside the cylindrical chamber filled with water, and working gas (air, argon) was injected into interelectrode space. Varying the duration of exposure (2–10 min) leads to changes in the chemical composition and biological activity of the liquid medium, and this approach is effective for proving of the methods in complex liquids. We found the erosion of the electrodes (stainless steel, duralumin) with the injection of argon and air. The erosion can affect reactions of the methods used, as a result, it makes a contribution to measured concentration. For further applications, it is necessary to consider these features to obtain the correct and reproducible results. When plasma exposure occurs with an electrode that is above the surface of the liquid and does not erode, both methods work in the proper way. But when erosion is present ions of eroded materials (iron, aluminum) contribute to the measurement of hydrogen peroxide concentration using the FOX method. A method with xylenol orange is proposed for taking this feature into account by measuring the concentration of metal ions. In the Griess assay it is possible to obtain strongly erroneous results due to visually similar color and close values of absorbance at the chosen wavelength (525 nm) for both low concentration of nitrites (within linear part of the calibration curve) of nitrites and high concentration (far beyond linear part of the calibration curve). In our research concentration of nitrites does drastically change in the experiment after changing material of the electrodes from stainless steel to duralumin. The Griess assay leads to the formation of a stable fluorescent complex when erosion of the metal electrodes is present.</p></div>","PeriodicalId":734,"journal":{"name":"Plasma Chemistry and Plasma Processing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Features of the FOX and Griess Method for Assessing the Biological Activity of Plasma Treated Solutions\",\"authors\":\"Victoria V. Gudkova,&nbsp;Darya A. Razvolyaeva,&nbsp;Valentin D. Borzosekov,&nbsp;Evgeny M. Konchekov\",\"doi\":\"10.1007/s11090-023-10418-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The paper reveals the problem of measuring reactive oxygen (ROS) and nitrogen (RNS) species’ concentrations in plasma treated water Milli-Q. We investigate the features of the FOX method for hydrogen peroxide concentration measurement and the Griess method for nitrite ions concentration spectrophotometric measurement using two different ways of an aqueous solution treatment. In the first case, the electrode (non-conducting high-temperature ceramics) was above the aqueous solution and the discharge was in the gas phase. In the second case, the electrodes were fixed around the perimeter inside the cylindrical chamber filled with water, and working gas (air, argon) was injected into interelectrode space. Varying the duration of exposure (2–10 min) leads to changes in the chemical composition and biological activity of the liquid medium, and this approach is effective for proving of the methods in complex liquids. We found the erosion of the electrodes (stainless steel, duralumin) with the injection of argon and air. The erosion can affect reactions of the methods used, as a result, it makes a contribution to measured concentration. For further applications, it is necessary to consider these features to obtain the correct and reproducible results. When plasma exposure occurs with an electrode that is above the surface of the liquid and does not erode, both methods work in the proper way. But when erosion is present ions of eroded materials (iron, aluminum) contribute to the measurement of hydrogen peroxide concentration using the FOX method. A method with xylenol orange is proposed for taking this feature into account by measuring the concentration of metal ions. In the Griess assay it is possible to obtain strongly erroneous results due to visually similar color and close values of absorbance at the chosen wavelength (525 nm) for both low concentration of nitrites (within linear part of the calibration curve) of nitrites and high concentration (far beyond linear part of the calibration curve). In our research concentration of nitrites does drastically change in the experiment after changing material of the electrodes from stainless steel to duralumin. The Griess assay leads to the formation of a stable fluorescent complex when erosion of the metal electrodes is present.</p></div>\",\"PeriodicalId\":734,\"journal\":{\"name\":\"Plasma Chemistry and Plasma Processing\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plasma Chemistry and Plasma Processing\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s11090-023-10418-8\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Chemistry and Plasma Processing","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11090-023-10418-8","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文揭示了等离子处理水 Milli-Q 中活性氧(ROS)和氮(RNS)物种浓度的测量问题。我们采用两种不同的水溶液处理方法,研究了过氧化氢浓度测量的 FOX 法和亚硝酸根离子浓度分光光度法的特点。在第一种情况下,电极(非导电高温陶瓷)位于水溶液上方,放电处于气相状态。在第二种情况下,电极四周固定在充满水的圆柱形腔体内,向电极间隙注入工作气体(空气、氩气)。不同的暴露时间(2-10 分钟)会导致液体介质的化学成分和生物活性发生变化,因此这种方法对于在复杂液体中验证方法非常有效。我们发现,注入氩气和空气会侵蚀电极(不锈钢、杜拉铝)。这种侵蚀会影响所用方法的反应,从而影响测量浓度。在进一步的应用中,有必要考虑这些特征,以获得正确且可重复的结果。当等离子曝露发生时,电极位于液体表面之上,不会发生侵蚀,这两种方法都能以正确的方式工作。但当出现侵蚀时,侵蚀材料(铁、铝)的离子会影响使用 FOX 方法测量过氧化氢的浓度。我们提出了一种使用二甲酚橙的方法,通过测量金属离子的浓度来考虑这一特点。在格里斯检测法中,由于亚硝酸盐的低浓度(在校准曲线的线性范围内)和高浓度(远远超出校准曲线的线性范围)在所选波长(525 nm)下的颜色和吸光度值在视觉上相似,因此有可能得到严重错误的结果。在我们的研究中,将电极材料从不锈钢改为杜拉铝后,亚硝酸盐的浓度在实验中发生了急剧变化。当金属电极受到侵蚀时,格里斯测定法会形成稳定的荧光复合物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Features of the FOX and Griess Method for Assessing the Biological Activity of Plasma Treated Solutions

Features of the FOX and Griess Method for Assessing the Biological Activity of Plasma Treated Solutions

Features of the FOX and Griess Method for Assessing the Biological Activity of Plasma Treated Solutions

The paper reveals the problem of measuring reactive oxygen (ROS) and nitrogen (RNS) species’ concentrations in plasma treated water Milli-Q. We investigate the features of the FOX method for hydrogen peroxide concentration measurement and the Griess method for nitrite ions concentration spectrophotometric measurement using two different ways of an aqueous solution treatment. In the first case, the electrode (non-conducting high-temperature ceramics) was above the aqueous solution and the discharge was in the gas phase. In the second case, the electrodes were fixed around the perimeter inside the cylindrical chamber filled with water, and working gas (air, argon) was injected into interelectrode space. Varying the duration of exposure (2–10 min) leads to changes in the chemical composition and biological activity of the liquid medium, and this approach is effective for proving of the methods in complex liquids. We found the erosion of the electrodes (stainless steel, duralumin) with the injection of argon and air. The erosion can affect reactions of the methods used, as a result, it makes a contribution to measured concentration. For further applications, it is necessary to consider these features to obtain the correct and reproducible results. When plasma exposure occurs with an electrode that is above the surface of the liquid and does not erode, both methods work in the proper way. But when erosion is present ions of eroded materials (iron, aluminum) contribute to the measurement of hydrogen peroxide concentration using the FOX method. A method with xylenol orange is proposed for taking this feature into account by measuring the concentration of metal ions. In the Griess assay it is possible to obtain strongly erroneous results due to visually similar color and close values of absorbance at the chosen wavelength (525 nm) for both low concentration of nitrites (within linear part of the calibration curve) of nitrites and high concentration (far beyond linear part of the calibration curve). In our research concentration of nitrites does drastically change in the experiment after changing material of the electrodes from stainless steel to duralumin. The Griess assay leads to the formation of a stable fluorescent complex when erosion of the metal electrodes is present.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Plasma Chemistry and Plasma Processing
Plasma Chemistry and Plasma Processing 工程技术-工程:化工
CiteScore
5.90
自引率
8.30%
发文量
73
审稿时长
6-12 weeks
期刊介绍: Publishing original papers on fundamental and applied research in plasma chemistry and plasma processing, the scope of this journal includes processing plasmas ranging from non-thermal plasmas to thermal plasmas, and fundamental plasma studies as well as studies of specific plasma applications. Such applications include but are not limited to plasma catalysis, environmental processing including treatment of liquids and gases, biological applications of plasmas including plasma medicine and agriculture, surface modification and deposition, powder and nanostructure synthesis, energy applications including plasma combustion and reforming, resource recovery, coupling of plasmas and electrochemistry, and plasma etching. Studies of chemical kinetics in plasmas, and the interactions of plasmas with surfaces are also solicited. It is essential that submissions include substantial consideration of the role of the plasma, for example, the relevant plasma chemistry, plasma physics or plasma–surface interactions; manuscripts that consider solely the properties of materials or substances processed using a plasma are not within the journal’s scope.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信