基于模式分析的7系列fpga读序列相关故障电气诊断

Xin Li, Jing Yang, P. Salinas
{"title":"基于模式分析的7系列fpga读序列相关故障电气诊断","authors":"Xin Li, Jing Yang, P. Salinas","doi":"10.1109/IPFA.2018.8452179","DOIUrl":null,"url":null,"abstract":"The BRAM block is a configurable memory module that attaches to a variety of BRAM interface controller. BRAM serves as a relatively large memory structure (i.e. larger than distributed RAMs or a bunch of D-flip-flop grouped together, but much smaller than off chip memory resources). In addition, multiple blocks can be cascaded to create still larger memory. The failure configuration type of BRAM in read operation was screened out by automatic test equipment (ATE). The failure pattern was created in Vivado which integrated logic analyzer (ILA) was inserted to monitor the failure BRAM data and compared against good BRAM data. The successful fault isolation of BRAM failure was mainly relied on pattern analysis as well as BRAM configuration.","PeriodicalId":382811,"journal":{"name":"2018 IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrical Diagnosis of 7 Series FPGAs Read Sequence Dependent Bram Failure Using Pattern Analysis\",\"authors\":\"Xin Li, Jing Yang, P. Salinas\",\"doi\":\"10.1109/IPFA.2018.8452179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The BRAM block is a configurable memory module that attaches to a variety of BRAM interface controller. BRAM serves as a relatively large memory structure (i.e. larger than distributed RAMs or a bunch of D-flip-flop grouped together, but much smaller than off chip memory resources). In addition, multiple blocks can be cascaded to create still larger memory. The failure configuration type of BRAM in read operation was screened out by automatic test equipment (ATE). The failure pattern was created in Vivado which integrated logic analyzer (ILA) was inserted to monitor the failure BRAM data and compared against good BRAM data. The successful fault isolation of BRAM failure was mainly relied on pattern analysis as well as BRAM configuration.\",\"PeriodicalId\":382811,\"journal\":{\"name\":\"2018 IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPFA.2018.8452179\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPFA.2018.8452179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

BRAM块是一个可配置的内存模块,它连接到各种BRAM接口控制器。BRAM作为一个相对较大的存储结构(即比分布式ram或一堆d触发器组合在一起更大,但比片外存储资源小得多)。此外,多个块可以级联以创建更大的内存。通过自动测试设备(ATE)筛选了BRAM在读操作中的故障配置类型。在Vivado中创建故障模式,并插入集成逻辑分析仪(ILA)来监测故障BRAM数据,并与正常BRAM数据进行比较。BRAM故障的成功隔离主要依赖于模式分析和BRAM配置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrical Diagnosis of 7 Series FPGAs Read Sequence Dependent Bram Failure Using Pattern Analysis
The BRAM block is a configurable memory module that attaches to a variety of BRAM interface controller. BRAM serves as a relatively large memory structure (i.e. larger than distributed RAMs or a bunch of D-flip-flop grouped together, but much smaller than off chip memory resources). In addition, multiple blocks can be cascaded to create still larger memory. The failure configuration type of BRAM in read operation was screened out by automatic test equipment (ATE). The failure pattern was created in Vivado which integrated logic analyzer (ILA) was inserted to monitor the failure BRAM data and compared against good BRAM data. The successful fault isolation of BRAM failure was mainly relied on pattern analysis as well as BRAM configuration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信