W. Jianguo, Huang Ling, Dong Wansheng, Chen Cixuan
{"title":"冲击电压发生器放电时高压试验大厅内的磁场分布","authors":"W. Jianguo, Huang Ling, Dong Wansheng, Chen Cixuan","doi":"10.1109/ICSMC2.2003.1428302","DOIUrl":null,"url":null,"abstract":"To protect equipment and personnel in high voltage test hall effectively, it is necessary to know the distributions of space electromagnetic field and frequency spectrum characteristics. A set of transient magnetic field waveform measurements and digital reconstruction method was used in discharge and withstand test of impulse voltage generator. Distributions of magnetic field and waveform characteristics have been measured. The results show that magnetic field of discharge test is larger than that of withstand test either in lightning impulse voltage test or in switching impulse voltage test. The magnetic field of many points have exceeded the level of computer misoperation and the rise time of waveform is also very short, so necessary protection and an EMC test to the equipment working in high voltage test hall are very necessary","PeriodicalId":272545,"journal":{"name":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Magnetic field distributions in high voltage test hall when impulse voltage generator discharges\",\"authors\":\"W. Jianguo, Huang Ling, Dong Wansheng, Chen Cixuan\",\"doi\":\"10.1109/ICSMC2.2003.1428302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To protect equipment and personnel in high voltage test hall effectively, it is necessary to know the distributions of space electromagnetic field and frequency spectrum characteristics. A set of transient magnetic field waveform measurements and digital reconstruction method was used in discharge and withstand test of impulse voltage generator. Distributions of magnetic field and waveform characteristics have been measured. The results show that magnetic field of discharge test is larger than that of withstand test either in lightning impulse voltage test or in switching impulse voltage test. The magnetic field of many points have exceeded the level of computer misoperation and the rise time of waveform is also very short, so necessary protection and an EMC test to the equipment working in high voltage test hall are very necessary\",\"PeriodicalId\":272545,\"journal\":{\"name\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMC2.2003.1428302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMC2.2003.1428302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetic field distributions in high voltage test hall when impulse voltage generator discharges
To protect equipment and personnel in high voltage test hall effectively, it is necessary to know the distributions of space electromagnetic field and frequency spectrum characteristics. A set of transient magnetic field waveform measurements and digital reconstruction method was used in discharge and withstand test of impulse voltage generator. Distributions of magnetic field and waveform characteristics have been measured. The results show that magnetic field of discharge test is larger than that of withstand test either in lightning impulse voltage test or in switching impulse voltage test. The magnetic field of many points have exceeded the level of computer misoperation and the rise time of waveform is also very short, so necessary protection and an EMC test to the equipment working in high voltage test hall are very necessary