冲击电压发生器放电时高压试验大厅内的磁场分布

W. Jianguo, Huang Ling, Dong Wansheng, Chen Cixuan
{"title":"冲击电压发生器放电时高压试验大厅内的磁场分布","authors":"W. Jianguo, Huang Ling, Dong Wansheng, Chen Cixuan","doi":"10.1109/ICSMC2.2003.1428302","DOIUrl":null,"url":null,"abstract":"To protect equipment and personnel in high voltage test hall effectively, it is necessary to know the distributions of space electromagnetic field and frequency spectrum characteristics. A set of transient magnetic field waveform measurements and digital reconstruction method was used in discharge and withstand test of impulse voltage generator. Distributions of magnetic field and waveform characteristics have been measured. The results show that magnetic field of discharge test is larger than that of withstand test either in lightning impulse voltage test or in switching impulse voltage test. The magnetic field of many points have exceeded the level of computer misoperation and the rise time of waveform is also very short, so necessary protection and an EMC test to the equipment working in high voltage test hall are very necessary","PeriodicalId":272545,"journal":{"name":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Magnetic field distributions in high voltage test hall when impulse voltage generator discharges\",\"authors\":\"W. Jianguo, Huang Ling, Dong Wansheng, Chen Cixuan\",\"doi\":\"10.1109/ICSMC2.2003.1428302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To protect equipment and personnel in high voltage test hall effectively, it is necessary to know the distributions of space electromagnetic field and frequency spectrum characteristics. A set of transient magnetic field waveform measurements and digital reconstruction method was used in discharge and withstand test of impulse voltage generator. Distributions of magnetic field and waveform characteristics have been measured. The results show that magnetic field of discharge test is larger than that of withstand test either in lightning impulse voltage test or in switching impulse voltage test. The magnetic field of many points have exceeded the level of computer misoperation and the rise time of waveform is also very short, so necessary protection and an EMC test to the equipment working in high voltage test hall are very necessary\",\"PeriodicalId\":272545,\"journal\":{\"name\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMC2.2003.1428302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMC2.2003.1428302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

为了有效地保护高压试验大厅中的设备和人员,有必要了解空间电磁场的分布和频谱特性。在脉冲电压发生器放电和耐压试验中,采用了一套瞬态磁场波形测量和数字重建方法。测量了磁场分布和波形特性。结果表明,无论是雷电冲击电压试验还是开关冲击电压试验,放电试验的磁场都大于耐压试验的磁场。许多点的磁场已经超过了计算机误操作的水平,波形的上升时间也很短,因此对工作在高压测试大厅的设备进行必要的保护和EMC测试是非常必要的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Magnetic field distributions in high voltage test hall when impulse voltage generator discharges
To protect equipment and personnel in high voltage test hall effectively, it is necessary to know the distributions of space electromagnetic field and frequency spectrum characteristics. A set of transient magnetic field waveform measurements and digital reconstruction method was used in discharge and withstand test of impulse voltage generator. Distributions of magnetic field and waveform characteristics have been measured. The results show that magnetic field of discharge test is larger than that of withstand test either in lightning impulse voltage test or in switching impulse voltage test. The magnetic field of many points have exceeded the level of computer misoperation and the rise time of waveform is also very short, so necessary protection and an EMC test to the equipment working in high voltage test hall are very necessary
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信