{"title":"等离子体腐蚀阳极膜的可靠性评价","authors":"Je-Boem Song, Jin-Tae Kim, Seung-Su Lee, Seong-Geun Oh, E. Oh, J. Yun","doi":"10.1109/ASMC.2016.7491133","DOIUrl":null,"url":null,"abstract":"Accelerated Degradation Test (ADT) is a test conducted under extreme stress conditions to accelerate degradation. In the plasma etching process, the life time of the anodic film deteriorates due to fatigue cracking, wear, and erosion arising from ion bombardment and radical reaction. However, ADT has yet to be studied in relation to plasma stress. A fault tree analysis are performed on plasma corrosion. The failure criterion of the corrosion is an increase in number of contamination particles. Since contamination particles are produced by an increase in by-products caused by corrosion, they can also be traced to the reduced mass of the oxide film. CF4, Ar, and O2 gas are used for the plasma corrosion test, and the acceleration factors are set as the pressure of the gases and the input power for plasma. This study proposes an efficient ADT design for the reliability analysis of anodic films under the plasma etching process.","PeriodicalId":264050,"journal":{"name":"2016 27th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability assessment of anodic films under plasma etching process\",\"authors\":\"Je-Boem Song, Jin-Tae Kim, Seung-Su Lee, Seong-Geun Oh, E. Oh, J. Yun\",\"doi\":\"10.1109/ASMC.2016.7491133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accelerated Degradation Test (ADT) is a test conducted under extreme stress conditions to accelerate degradation. In the plasma etching process, the life time of the anodic film deteriorates due to fatigue cracking, wear, and erosion arising from ion bombardment and radical reaction. However, ADT has yet to be studied in relation to plasma stress. A fault tree analysis are performed on plasma corrosion. The failure criterion of the corrosion is an increase in number of contamination particles. Since contamination particles are produced by an increase in by-products caused by corrosion, they can also be traced to the reduced mass of the oxide film. CF4, Ar, and O2 gas are used for the plasma corrosion test, and the acceleration factors are set as the pressure of the gases and the input power for plasma. This study proposes an efficient ADT design for the reliability analysis of anodic films under the plasma etching process.\",\"PeriodicalId\":264050,\"journal\":{\"name\":\"2016 27th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 27th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASMC.2016.7491133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 27th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASMC.2016.7491133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

加速降解试验(ADT)是在极端应力条件下进行的加速降解试验。在等离子体刻蚀过程中,由于离子轰击和自由基反应引起的疲劳开裂、磨损和侵蚀,阳极膜的寿命下降。然而,ADT与血浆应激的关系尚待研究。对等离子体腐蚀进行了故障树分析。腐蚀的失效判据是污染颗粒数量的增加。由于污染颗粒是由腐蚀引起的副产品增加而产生的,因此它们也可以追溯到氧化膜质量的减少。等离子体腐蚀试验采用CF4、Ar和O2气体,加速系数设置为气体压力和等离子体输入功率。本研究提出了一种有效的ADT设计,用于等离子体刻蚀过程中阳极膜的可靠性分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability assessment of anodic films under plasma etching process
Accelerated Degradation Test (ADT) is a test conducted under extreme stress conditions to accelerate degradation. In the plasma etching process, the life time of the anodic film deteriorates due to fatigue cracking, wear, and erosion arising from ion bombardment and radical reaction. However, ADT has yet to be studied in relation to plasma stress. A fault tree analysis are performed on plasma corrosion. The failure criterion of the corrosion is an increase in number of contamination particles. Since contamination particles are produced by an increase in by-products caused by corrosion, they can also be traced to the reduced mass of the oxide film. CF4, Ar, and O2 gas are used for the plasma corrosion test, and the acceleration factors are set as the pressure of the gases and the input power for plasma. This study proposes an efficient ADT design for the reliability analysis of anodic films under the plasma etching process.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信