{"title":"供电电流监测是否可以应用于混合asic的模拟和数字部分的测试?","authors":"D. A. Camplin, I. Bell, G. Taylor, B. Bannister","doi":"10.1109/EDAC.1992.205994","DOIUrl":null,"url":null,"abstract":"Investigations are made into the suitability of supply current monitoring as a technique for the testing of analogue circuit modules. Iddq monitoring is already recognised in the digital field. The possibility of a unified testing approach for mixed ASICs is raised. The potential effectiveness of the method is investigated. Simulation results are reported to illustrate typical supply current levels for nominal and defective circuits. Analogue fault detection by this technique is compared with detection by observation of the circuit's output.<<ETX>>","PeriodicalId":285019,"journal":{"name":"[1992] Proceedings The European Conference on Design Automation","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Can supply current monitoring be applied to the testing of analogue as well as digital portions of mixed ASICs?\",\"authors\":\"D. A. Camplin, I. Bell, G. Taylor, B. Bannister\",\"doi\":\"10.1109/EDAC.1992.205994\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Investigations are made into the suitability of supply current monitoring as a technique for the testing of analogue circuit modules. Iddq monitoring is already recognised in the digital field. The possibility of a unified testing approach for mixed ASICs is raised. The potential effectiveness of the method is investigated. Simulation results are reported to illustrate typical supply current levels for nominal and defective circuits. Analogue fault detection by this technique is compared with detection by observation of the circuit's output.<<ETX>>\",\"PeriodicalId\":285019,\"journal\":{\"name\":\"[1992] Proceedings The European Conference on Design Automation\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-03-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1992] Proceedings The European Conference on Design Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDAC.1992.205994\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1992] Proceedings The European Conference on Design Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDAC.1992.205994","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Can supply current monitoring be applied to the testing of analogue as well as digital portions of mixed ASICs?
Investigations are made into the suitability of supply current monitoring as a technique for the testing of analogue circuit modules. Iddq monitoring is already recognised in the digital field. The possibility of a unified testing approach for mixed ASICs is raised. The potential effectiveness of the method is investigated. Simulation results are reported to illustrate typical supply current levels for nominal and defective circuits. Analogue fault detection by this technique is compared with detection by observation of the circuit's output.<>