{"title":"使用PXI的定时和触发构建测试应用程序","authors":"L. Duraiappah","doi":"10.1109/AUTEST.2002.1047894","DOIUrl":null,"url":null,"abstract":"The PXI platform provides sophisticated synchronization capabilities for automated test applications. This paper provides a technical overview of triggering and synchronization capabilities of PXI, including the PXI Trigger Bus, the Star Trigger Bus, and the back-plane clock. The test applications of triggering and synchronization are discussed and demonstrated, including: synchronization of multiple digitizers/scopes to simultaneously sample multiple channels; synchronization of a scope (or multiple scopes) to a source to accomplish time domain measurements of the DUT response to stimulus; position based measurements (digitizers synchronized to counter/timers); synchronization of a DMM to a switch to access multiple test nodes when the DUT has settled to a steady state; and synchronization of motion control with image acquisition.","PeriodicalId":372875,"journal":{"name":"Proceedings, IEEE AUTOTESTCON","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Building test applications using timing and triggering with PXI\",\"authors\":\"L. Duraiappah\",\"doi\":\"10.1109/AUTEST.2002.1047894\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The PXI platform provides sophisticated synchronization capabilities for automated test applications. This paper provides a technical overview of triggering and synchronization capabilities of PXI, including the PXI Trigger Bus, the Star Trigger Bus, and the back-plane clock. The test applications of triggering and synchronization are discussed and demonstrated, including: synchronization of multiple digitizers/scopes to simultaneously sample multiple channels; synchronization of a scope (or multiple scopes) to a source to accomplish time domain measurements of the DUT response to stimulus; position based measurements (digitizers synchronized to counter/timers); synchronization of a DMM to a switch to access multiple test nodes when the DUT has settled to a steady state; and synchronization of motion control with image acquisition.\",\"PeriodicalId\":372875,\"journal\":{\"name\":\"Proceedings, IEEE AUTOTESTCON\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings, IEEE AUTOTESTCON\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AUTEST.2002.1047894\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings, IEEE AUTOTESTCON","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUTEST.2002.1047894","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

PXI平台为自动化测试应用程序提供了复杂的同步功能。本文提供了PXI触发和同步功能的技术概述,包括PXI触发总线、星触发总线和背板时钟。讨论并演示了触发和同步的测试应用,包括:多个数字化仪/示波器同步以同时采样多个通道;将一个示波器(或多个示波器)同步到一个源,以完成被测对象对刺激响应的时域测量;基于位置的测量(与计数器/计时器同步的数字化仪);当被测设备达到稳定状态时,DMM与交换机的同步以访问多个测试节点;以及运动控制与图像采集的同步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Building test applications using timing and triggering with PXI
The PXI platform provides sophisticated synchronization capabilities for automated test applications. This paper provides a technical overview of triggering and synchronization capabilities of PXI, including the PXI Trigger Bus, the Star Trigger Bus, and the back-plane clock. The test applications of triggering and synchronization are discussed and demonstrated, including: synchronization of multiple digitizers/scopes to simultaneously sample multiple channels; synchronization of a scope (or multiple scopes) to a source to accomplish time domain measurements of the DUT response to stimulus; position based measurements (digitizers synchronized to counter/timers); synchronization of a DMM to a switch to access multiple test nodes when the DUT has settled to a steady state; and synchronization of motion control with image acquisition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信