{"title":"用于高性能电子模块冷却的增强型热虹吸热回路的实验研究","authors":"R. C. Chu, R. Simons, G. Chrysler","doi":"10.1109/STHERM.1999.762421","DOIUrl":null,"url":null,"abstract":"This paper discusses the investigation of module cooling utilizing an enhanced thermosyphon heat loop as an alternative to direct air cooling or liquid-to-air cooling with forced convection of the liquid. Using water as the working fluid in the thermosyphon, experiments were conducted to investigate the effects of fill volume, heat load, and condenser air flow rate on overall thermosyphon performance in terms of thermal resistance. Enhancement of evaporator performance using fins was also investigated and the results are reported in the paper.","PeriodicalId":253023,"journal":{"name":"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Experimental investigation of an enhanced thermosyphon heat loop for cooling of a high performance electronics module\",\"authors\":\"R. C. Chu, R. Simons, G. Chrysler\",\"doi\":\"10.1109/STHERM.1999.762421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the investigation of module cooling utilizing an enhanced thermosyphon heat loop as an alternative to direct air cooling or liquid-to-air cooling with forced convection of the liquid. Using water as the working fluid in the thermosyphon, experiments were conducted to investigate the effects of fill volume, heat load, and condenser air flow rate on overall thermosyphon performance in terms of thermal resistance. Enhancement of evaporator performance using fins was also investigated and the results are reported in the paper.\",\"PeriodicalId\":253023,\"journal\":{\"name\":\"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STHERM.1999.762421\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STHERM.1999.762421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental investigation of an enhanced thermosyphon heat loop for cooling of a high performance electronics module
This paper discusses the investigation of module cooling utilizing an enhanced thermosyphon heat loop as an alternative to direct air cooling or liquid-to-air cooling with forced convection of the liquid. Using water as the working fluid in the thermosyphon, experiments were conducted to investigate the effects of fill volume, heat load, and condenser air flow rate on overall thermosyphon performance in terms of thermal resistance. Enhancement of evaporator performance using fins was also investigated and the results are reported in the paper.