HEP实验电子学低功率辐射硬芦苇-所罗门码保护的65纳米串行化器的特性

D. Felici, S. Bonacini, M. Ottavi
{"title":"HEP实验电子学低功率辐射硬芦苇-所罗门码保护的65纳米串行化器的特性","authors":"D. Felici, S. Bonacini, M. Ottavi","doi":"10.1109/DFT.2015.7315160","DOIUrl":null,"url":null,"abstract":"The availability of low-power, radiation-resistant components has an enormous importance in the development of the electronic systems for modern detectors in a High Energy Physics (HEP) experiment. This paper describes the characterization in terms of radiation effects of two serializer blocks within a high speed transmitter, prior developed with the objective of achieving a power consumption of less than 30 mW at the operating speed of 4.8 Gbit/sec. Within the first serializer, called “simple TMR”, a traditional solution, based on the hardware redundancy, has been implemented. In the second case a new architecture, less power consuming, called “code protected”, has been proposed. The tests previously performed shown an average consumption of ~30 mW and ~19 mW, respectively, for a bit rate of 4.8 Gbit/sec but do not fully clarify if the blocks are suitable for working under extremely high radiation levels. Hence, a deep radiation hardness investigation has been performed and presented here to confirm the availability of these blocks in a HEP electronic system. SEU sensitivities are measured and bit error rates better than 2 E-15 are obtained, confirming that the “code protected” solution assures reliable communications in HEP experiments environment with a smaller power consumption. These blocks have also been designed and tested to cope with a total ionizing dose of 100 Mrad over 10 years of operation.","PeriodicalId":383972,"journal":{"name":"2015 IEEE International Symposium on Defect and Fault Tolerance in VLSI and Nanotechnology Systems (DFTS)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Characterization of low power radiation-hard reed-solomon code protected serializers in 65-nm for HEP experiments electronics\",\"authors\":\"D. Felici, S. Bonacini, M. Ottavi\",\"doi\":\"10.1109/DFT.2015.7315160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The availability of low-power, radiation-resistant components has an enormous importance in the development of the electronic systems for modern detectors in a High Energy Physics (HEP) experiment. This paper describes the characterization in terms of radiation effects of two serializer blocks within a high speed transmitter, prior developed with the objective of achieving a power consumption of less than 30 mW at the operating speed of 4.8 Gbit/sec. Within the first serializer, called “simple TMR”, a traditional solution, based on the hardware redundancy, has been implemented. In the second case a new architecture, less power consuming, called “code protected”, has been proposed. The tests previously performed shown an average consumption of ~30 mW and ~19 mW, respectively, for a bit rate of 4.8 Gbit/sec but do not fully clarify if the blocks are suitable for working under extremely high radiation levels. Hence, a deep radiation hardness investigation has been performed and presented here to confirm the availability of these blocks in a HEP electronic system. SEU sensitivities are measured and bit error rates better than 2 E-15 are obtained, confirming that the “code protected” solution assures reliable communications in HEP experiments environment with a smaller power consumption. These blocks have also been designed and tested to cope with a total ionizing dose of 100 Mrad over 10 years of operation.\",\"PeriodicalId\":383972,\"journal\":{\"name\":\"2015 IEEE International Symposium on Defect and Fault Tolerance in VLSI and Nanotechnology Systems (DFTS)\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Symposium on Defect and Fault Tolerance in VLSI and Nanotechnology Systems (DFTS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DFT.2015.7315160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Defect and Fault Tolerance in VLSI and Nanotechnology Systems (DFTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DFT.2015.7315160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在高能物理(HEP)实验中,低功率、抗辐射元件的可用性对现代探测器电子系统的发展具有极其重要的意义。本文描述了高速发射机内两个串行块的辐射效应特性,该发射机先前开发的目标是在4.8 Gbit/sec的运行速度下实现低于30 mW的功耗。在第一个序列化器(称为“简单TMR”)中,已经实现了基于硬件冗余的传统解决方案。在第二种情况下,提出了一种新的架构,称为“代码保护”,功耗更低。先前进行的测试显示,在比特率为4.8 Gbit/sec的情况下,平均功耗分别为~30 mW和~19 mW,但没有完全阐明这些模块是否适合在极高的辐射水平下工作。因此,进行了深入的辐射硬度调查,并在此提出,以确认这些块在HEP电子系统中的可用性。测量了SEU的灵敏度,获得了优于2 E-15的误码率,证实了“码保护”解决方案在HEP实验环境下以更小的功耗保证了可靠的通信。经过设计和测试,这些区块在10年的运行中可以承受100毫当量的总电离剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characterization of low power radiation-hard reed-solomon code protected serializers in 65-nm for HEP experiments electronics
The availability of low-power, radiation-resistant components has an enormous importance in the development of the electronic systems for modern detectors in a High Energy Physics (HEP) experiment. This paper describes the characterization in terms of radiation effects of two serializer blocks within a high speed transmitter, prior developed with the objective of achieving a power consumption of less than 30 mW at the operating speed of 4.8 Gbit/sec. Within the first serializer, called “simple TMR”, a traditional solution, based on the hardware redundancy, has been implemented. In the second case a new architecture, less power consuming, called “code protected”, has been proposed. The tests previously performed shown an average consumption of ~30 mW and ~19 mW, respectively, for a bit rate of 4.8 Gbit/sec but do not fully clarify if the blocks are suitable for working under extremely high radiation levels. Hence, a deep radiation hardness investigation has been performed and presented here to confirm the availability of these blocks in a HEP electronic system. SEU sensitivities are measured and bit error rates better than 2 E-15 are obtained, confirming that the “code protected” solution assures reliable communications in HEP experiments environment with a smaller power consumption. These blocks have also been designed and tested to cope with a total ionizing dose of 100 Mrad over 10 years of operation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信